This study aimed to histologically evaluate the effects of XPEED and SLA surface on the mineral apposition rate (MAR) at 3 and 5 weeks in titanium dental implants placed in human bone. In total, 17 titanium dental implants with XPEED surface ( = 9) used as test and SLA surface ( = 8) used as control were included in this study. Each patient received four doses of tetracycline 500 mg at 12 h intervals 2 weeks prior to biopsy retrieval.
View Article and Find Full Text PDFTitanium implants undergo an aging process through surface hydrocarbon deposition, resulting in decreased wettability and bioactivity. Plasma treatment was shown to significantly reduce surface hydrocarbons, thus improving implant hydrophilicity and enhancing the osseointegration process. This study investigates the effect of plasma surface treatment on bone-to-implant contact (BIC) of implants presenting a nanostructured calcium-incorporated surface (XPEED).
View Article and Find Full Text PDFBackground: Implant surface topography is a key element in achieving osseointegration. Nanostructured surfaces have shown promising results in accelerating and improving bone healing around dental implants. The main objective of the present clinical and histological study is to compare, at 4 and 6 weeks, (w) bone-to-implant contact in implants having either machined surface (MAC), sandblasted, large grit, acid-etched implant surface (SLA) medium roughness surface or a nanostructured calcium-incorporated surface (XPEED®).
View Article and Find Full Text PDFJ Clin Med
October 2021
(1) Background: In the lateral area of the maxilla, the alveolar bone can lose significant volume due to maxillary sinus pneumatization following teeth extractions. This preliminary study evaluated the effectiveness of a novel technique for one-stage sinus lifting and simultaneous implant placement in cases with less than 1.5 mm residual alveolar bone.
View Article and Find Full Text PDFMacro- and micro-geometry are among the factors influencing implant stability and potentially determining loading protocol. The purpose of this study was to test a protocol for early loading by controlling implant stability with the selection of fixtures with different thread depth according to the bone density of the implant site. Patients needing implant therapy for fixed prosthetic rehabilitation were treated by inserting fixtures with four different thread diameters, selected based on clinical assessment of bone quality at placement (D1, D2, D3, and D4, according to Misch classification).
View Article and Find Full Text PDFObjective: In the anterior regions, the resorption of the buccal bone after tooth extraction leads to a contraction of the overlying soft tissues, resulting in an esthetic problem, particularly with immediate implant placement. In the socket shield technique, the buccal root section of the tooth is maintained, to preserve the buccal bone for immediate implant placement. The aim of this prospective study was to investigate the survival, stability, and complication rates of implants placed using a "modified" socket shield technique.
View Article and Find Full Text PDFWe demonstrate a flexible strain-gauge sensor and its use in a wearable application for heart rate detection. This polymer-based strain-gauge sensor was fabricated using a double-sided fabrication method with polymer and metal, i.e.
View Article and Find Full Text PDFObjective: The aim of the present study was to compare the survival, stability, and complications of immediately loaded implants placed in postextraction sockets and healed sites.
Methods: Over a 2-year period, all patients presenting with partial or complete edentulism of the maxilla and/or mandible (healed site group, at least 4 months of healing after tooth extraction) or in need of replacement of nonrecoverable failing teeth (postextraction group) were considered for inclusion in this study. Tapered implants featuring a nanostructured calcium-incorporated surface were placed and loaded immediately.
Background: This study was to investigate the effect of collagen grafted porous biphasic calcium phosphate (BCP) on cell attachment, proliferation, and differentiation. Porous BCP scaffolds with interconnected micropore structure were prepared with were prepared and then grafted with a collagen type I. The hydroxyapatite (HA) and β-tricalcium phosphate (TCP) ratio of the TCP scaffolds was about 60/40 and the collagen was crosslinked on the TCP scaffold surface (collagen-TCP).
View Article and Find Full Text PDFRecently a submicron particle of biphasic calcium phosphate ceramic (BCP) with through-hole (donut-shaped BCP (d-BCP)) was developed for improving the osteoconductivity. This study was performed to examine the usefulness of d-BCP for the delivery of osteoinductive rhBMP2 and the effectiveness on cranial bone regeneration. The d-BCP was soaked in rhBMP2 solution and then freeze-dried.
View Article and Find Full Text PDFPurpose: This study aimed to evaluate the effect of implant thread depth on primary stability in low density bone.
Materials And Methods: The insertion torque was measured by inserting Ti implants with different thread depths into solid rigid polyurethane blocks (Sawbones) with three different bone densities (0.16 g/cm(3), 0.
Purpose: We have previously reported that tetra-cell adhesion molecule (T-CAM) markedly enhanced the differentiation of osteoblast-like cells grown on anorganic bone mineral (ABM). T-CAM comprises recombinant peptides containing the Arg-Gly-Asp (RGD) sequence in the tenth type III domain, Pro-His-Ser-Arg-Asn (PHSRN) sequence in the ninth type III domain of fibronectin (FN), and the Glu-Pro-Asp-Ilu-Met (EPDIM) and Tyr-His (YH) sequence in the fourth fas-1 domain of βig-h3. Therefore, the purpose of this study was to evaluate the cellular activity of osteoblast-like cells and the new bone formation on ABM coated with T-CAM, while comparing the results with those of synthetic cell binding peptide (PepGen P-15).
View Article and Find Full Text PDFClin Oral Implants Res
November 2012
Objectives: This study evaluated cytocompatibility and osseointegration of the titanium (Ti) implants with resorbable blast media (RBM) surfaces produced by grit-blasting or XPEED(®) surfaces by coating of the nanostructured calcium.
Material And Methods: Ti implants with XPEED(®) surfaces were hydrothermally prepared from Ti implants with RBM surfaces in a solution containing alkaline calcium. The surface characteristics were evaluated by using a scanning electron microscope (SEM) and surface roughness measuring system.
In this study, we prepared adriamycin (ADR)-encapsulated nanoparticles using deoxycholic acid-conjugated dextran (DexDA). Its antitumor activity was evaluated using CT 26 tumor cells in vitro and in vivo. ADR-incorporated DexDA nanoparticles have spherical shapes and their particle sizes were ranged about 50-200.
View Article and Find Full Text PDFIn order to increase biocompatibility, many dental implants have been studied by immobilization of biomolecules on biomaterials. We used l-3,4-dihydroxyphenylalanine (L-DOPA) as a biomolecule for surface-modified titanium. Water contact angles of nontreated titanium discs (negative control), etched titanium discs (positive control), and titanium discs treated with L-DOPA following the etching process (experimental group) were 82.
View Article and Find Full Text PDFObjectives: This study investigated the efficacy of new bone graft substitutes - biphasic calcium phosphates (BCP) made of submicron-sized grains with fully interconnected wide-range micron-scale pores in two different macrodesigns: donut shaped with a 300-400 microm central macropore (n-BCP-1) or rod-shaped (n-BCP-2)--in the healing of rabbit calvarial defects, and compared their bone-healing properties with those of various commercial bone substitutes, which included substitutes with similar BCP composition (MBCP and Osteon), anorganic bovine bone (Bio-Oss), and beta-TCP (Cerasorb).
Material And Methods: The surface morphology of the bone substitutes was investigated using scanning electron microscopy (SEM). Defects 8 mm in diameter were created in the calvaria of 30 adult male New Zealand White rabbits and were filled with six types of bone substitutes.
A novel protocol for the synthesis of biocompatible and degradation controlled poly(lactic-co-glycolic acid) grafted hyaluronic acid (HA-PLGA) was successfully developed for periodontal barrier applications. HA was chemically modified with adipic acid dihydrazide (ADH) in the mixed solvent of water and ethanol, which resulted in a high degree of HA modification up to 85 mol.%.
View Article and Find Full Text PDFThe biocompatibility of calcium ion (Ca)-incorporated Ti6Al4V alloy implants, produced by hydrothermal treatment using a Ca-containing solution, was investigated. The surface characteristics were evaluated by scanning electron microscopy, thin-film X-ray diffractometry, Auger electron spectroscopy, and stylus profilometry. The viability of MC3T3-E1 cells on Ca-incorporated machined Ti6Al4V surfaces with different oxide thicknesses was compared with that on untreated machined Ti6Al4V surfaces with MTT assay.
View Article and Find Full Text PDF