: Recent advancements in hip arthroplasty aim to enhance the stability, longevity, and functionality of femoral implants. However, the distal fitting of femoral stems, often caused by metaphyseal-diaphyseal mismatch, remains a significant issue, particularly in patients with Dorr type A femora. Such mismatches can result in suboptimal implant performance, leading to potential complications.
View Article and Find Full Text PDFBackground: The purpose of this study was to elucidate the relationship between the orientation of the osseous structure of the proximal femur encountered during total hip arthroplasty (THA) and preoperative femoral anteversion (FA).
Methods: Three-dimensional models were constructed using full-length lower extremity computed tomography images from a total of 80 participants. Femoral neck cutting was performed at heights of 5, 10, and 15 mm relative to the lesser trochanter.
Ethnopharmacological Relevance: Osteoarthritis (OA) is the most prevalent type of arthritis worldwide and a leading cause of years lost to pain and disability. Among the current pharmacological treatments for OA, symptomatic slow-acting drugs for OA (SYSADOA) induce pain relief and aim to improve joint function by relieving inflammation while causing fewer gastrointestinal and cardiovascular adverse events than non-steroidal anti-inflammatory drugs (NSAIDs). SKCPT is a herbal SYSADOA formulated from Clematis mandshurica, Trichosanthes kirilowii, and Prunella vulgaris powdered extracts.
View Article and Find Full Text PDFDuring the operation of synaptic devices based on traditional conductive filament (CF) models, the formation and dissolution of CFs are usually uncertain. Moreover, when the device is operated for a long time, the CFs may dissolve due to both the Joule heat generated by the device itself and the thermal coupling between the devices. These problems seriously reduce the reliability and stability of the synaptic device.
View Article and Find Full Text PDFThe aim of this study was to investigate the biomechanical effects of stem extension with a medial tibial bone defect in primary total knee arthroplasty (TKA) on load distribution and stress in the proximal tibia using finite element (FE) analysis.FE simulations were performed on the tibia bone to evaluate the stress and strain on the tibia bone and bone cement. This was done to investigate the stress shielding effect, stability of the tibia plate, and the biomechanical effects in TKA models with various medial defects and different stem length models.
View Article and Find Full Text PDFBackground and objective With the steady advancement of computer-assisted surgical techniques, the importance of assessing and researching technology related to total knee arthroplasty (TKA) procedures has increased. Augmented reality (AR), a recently proposed next-generation technology, is expected to enhance the precision of orthopedic surgery by providing a more efficient and cost-effective approach. However, the accuracy of image-based AR in TKA surgery has not been established.
View Article and Find Full Text PDFPericapsular nerve group (PENG) block and periarticular injection (PAI) provide motor-sparing analgesia following hip surgery. We hypothesized that PAI offers non-inferior pain relief compared with PENG block in patients undergoing primary total hip arthroplasty (THA). In this randomized trial, 66 patients who underwent primary THA under spinal anesthesia were assigned to the PENG or PAI groups.
View Article and Find Full Text PDFIntroduction: The purpose of this study was to evaluate peripheral nerve block (PNB) effectiveness in postoperative pain management and surgical outcomes for displaced femoral-neck fracture in geriatric patients (>70 years) who underwent bipolar hemiarthroplasty (BHA).
Methods: From January 2017 to December 2021, 231 geriatric patients with displaced femoral-neck fracture who consecutively underwent BHA were retrospectively reviewed. Patients were divided into two groups: the patient-controlled analgesia (PCA) group (n = 132) who received only intravenous (IV) PCA for postoperative pain management, and all others who received PNB with IV PCA (PNB+PCA) such as femoral nerve block or fascia iliaca compartment block after surgery (n = 99).
Stimulating the brain in a precise location is crucial in ultrasound neuromodulation. However, improving the resolution proves a challenge owing to the characteristics of transcranial focused ultrasound. In this paper, we present a new neuromodulation system that overcomes the existing limitations based on an acoustic radiation force with a frequency-modulated waveform and standing waves.
View Article and Find Full Text PDFBackground: The cause of early septic failure after two-stage exchange revision total knee arthroplasty (TKA) for chronic periprosthetic joint infection (PJI) and the factors affecting it are not well known. The purpose of this study was to determine the surgical outcomes and the risk factors for early septic failure after two-stage revision TKA for chronic PJI.
Methods: We identified a total of 246 adult patients who met the Musculoskeletal Infection Society (MSIS) diagnostic criteria for chronic PJI at two academic tertiary hospitals from March 2012 to December 2018.
The metallic conductive filament (CF) model, which serves as an important conduction mechanism for realizing synaptic functions in electronic devices, has gained recognition and is the subject of extensive research. However, the formation of CFs within the active layer is plagued by issues such as uncontrolled and random growth, which severely impacts the stability of the devices. Therefore, controlling the growth of CFs and improving the performance of the devices have become the focus of that research.
View Article and Find Full Text PDFBackground: A postoperative radiograph in total hip arthroplasty (THA) is usually obtained to evaluate the inclination and anteversion of the acetabular components. However, there is no gold-standard method for calculating the exact inclination and anteversion of the acetabular components on post-THA radiographs. We aimed to measure the actual anteversion of the acetabular component on postoperative radiographs by obtaining correlation data between the virtual and actual acetabular component positioning using virtual three-dimensional (3D) surgery.
View Article and Find Full Text PDFThe utility of α-defensin (AD), leukocyte esterase (LE) levels, and metagenomics sequencing as diagnostic tools for prosthetic joint infection (PJI) has been suggested, but there are few studies among the Asian population. This study aimed to evaluate the diagnostic performance of various biomarkers for PJI and the role of the microbiome in the synovial fluid of patients with prostheses. Patients with suspected knee PJI were enrolled, and their blood and synovial fluid were collected.
View Article and Find Full Text PDFThe effect of peripheral nerve block (PNB) according to leg lengthening following total hip arthroplasty (THA) has not been studied yet. The purpose of this study was to investigate the effect of PNB according to the change in leg length after THA. From January 2016 to August 2021, 353 patients who underwent unilateral THA for osteonecrosis of the femoral head or osteoarthritis of the hip joint were retrospectively reviewed.
View Article and Find Full Text PDF. Although recent studies have shown that mechanical stress plays an important role in ultrasound neuromodulation, the magnitude and distribution of the mechanical stress generated in tissues by focused ultrasound transducers have not been adequately examined. Various acoustic radiation force (ARF) equations used in previous studies have been evaluated based on the tissue displacement results and are suitable for estimating the displacement.
View Article and Find Full Text PDFBackground: Intra-articular injection of autologous culture-expanded adipose-derived mesenchymal stem cells (ADMSCs) has introduced a promising treatment option for knee osteoarthritis. Although the clinical efficacy and safety of ADMSCs have been reported, the treatment remains controversial owing to the small sample sizes and heterogeneous osteoarthritis grades in previous studies.
Purpose: To assess the efficacy and safety of intra-articular injection of ADMSCs as compared with placebo in alleviating pain and improving functional capacity in a large sample of patients with knee osteoarthritis of Kellgren-Lawrence (K-L) grade 3.
Introduction: This study aimed to compare the clinical outcomes of silicon ring tourniquets and conventional pneumatic tourniquets in total knee arthroplasty (TKA). The study compared the operation time, total bleeding amount, length from the tourniquet distal end to the patella superior pole (L_TP), and complications related to the two tourniquet application methods and attempted to determine whether the silicon ring tourniquet has advantages over conventional pneumatic tourniquets.
Materials And Methods: This prospective comparative study included 30 patients who underwent bilateral simultaneous TKA for degenerative osteoarthritis in August to December 2021.
Purpose: The aim of this study was to compare the anatomical structures of the acetabular rim around the anterior inferior iliac spine (AIIS) ridge that indicate anterior focal coverage of acetabulum between the sexes using a three-dimensional (3D) model.
Methods: 3D models of 71 adults (38 men and 33 women) with normal hip joints were used. Based on the location of the inflection point (IP) of the acetabular rim around the AIIS ridge, the patients were classified into anterior and posterior types, and the ratios thereof for each sex were compared.
Sensors (Basel)
February 2023
Interest in underwater transducers has persisted since the mid-1900s. Underwater transducers are designed in various shapes using various materials depending on the purpose of use, such as to achieve high power, improve broadband, and enhance beam steering. Therefore, in this study, an analysis is conducted according to the structural shape of the transducer, exterior material, and active material.
View Article and Find Full Text PDFUnderwater detection is accomplished using an underwater ultrasonic sensor, sound navigation and ranging (SONAR). Stealth to avoid detection by SONAR plays a major role in modern underwater warfare. In this study, we propose a smart skin that avoids detection by SONAR via controlling the signal reflected from an unmanned underwater vehicle (UUV).
View Article and Find Full Text PDFWe sought to determine whether multiple drilling (MD) combined with the injection of recombinant human bone morphogenetic protein-2 (rhBMP-2) and β-tricalcium phosphate (β-TCP) could improve survival of the femoral head in pre-collapse lesions of non-traumatic osteonecrosis of the femoral head (ONFH) as compared with MD alone. We conducted a single-site, off-label, comparative and prospective cohort study between November 2017 and May 2019. We enrolled 25 hips (25 patients) with non-traumatic ONFH (Ficat-Arlet stage 2A or less).
View Article and Find Full Text PDFPurpose: We sought to compare the radiographic parameters concerning the sagittal alignment of the standing whole-body skeletons between the knee extension group and control group using the low-dose biplanar X-ray system in a young adult population without knee pain, and to investigate the associated variables for the sagittal knee angle (sagKA) among the radiographic parameters of global sagittal alignment.
Materials And Methods: We reviewed whole-body standing sagittal radiographs of 124 young adults taken from December 2018 to May 2020 in a single institution. We compared the radiographic parameters concerning the lower extremity sagittal alignment and global sagittal alignment between the knee extension group and control group.