Publications by authors named "Kusaka A"

Cine-magnetic resonance imaging (MRI) has been used to track respiratory-induced motion of the liver and tumor and assist in the accurate delineation of tumor volume. Recent developments in compressed sensitivity encoding (SENSE; CS) have accelerated temporal resolution while maintaining contrast resolution. This study aimed to develop and assess hepatobiliary phase (HBP) cine-MRI scans using CS.

View Article and Find Full Text PDF

The heat sensitivity of reproduction is a critical determinant of population persistence under climate change. However, the heat sensitivity of gametes has been much less studied relative to that of adults. We developed a method to measure the heat tolerance limits of lizard sperm cells, and used the method to test several aspects of sperm cell thermal biology in the brown anole lizard (Anolis sagrei).

View Article and Find Full Text PDF
Article Synopsis
  • Liquid biopsy (LB) is a minimally invasive method for analyzing tumor-derived materials, and this study explores the potential of bile as a superior source of cell-free DNA (cfDNA) compared to plasma for detecting mutations in biliary tract cancers.
  • The research involved collecting cfDNA from the bile of 24 cancer cases, including various types of biliary tract cancers, and applying a multigene panel to identify cancer driver mutations.
  • Results indicated that bile yielded a higher detection rate of cancer driver mutations, with 54% of bile samples testing positive compared to just 17% of plasma samples, highlighting bile's effectiveness for liquid biopsy analysis.
View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to evaluate the impact of preoperative chemotherapy on serum zinc levels in patients with pancreatic cancer who underwent surgery between 2013 and 2019.
  • Out of 231 patients, those who received chemotherapy showed a significant decrease in serum zinc concentrations after treatment, dropping from 79.3 μg/dl to 68.7 μg/dl.
  • The findings suggest that preoperative chemotherapy lowers serum zinc levels consistently across different treatment regimens, highlighting the importance of monitoring zinc levels and considering supplementation for pancreatic cancer patients preparing for surgery.
View Article and Find Full Text PDF

Purpose: To compare the utility of thin-slice fat-suppressed single-shot T2-weighted imaging (T2WI) with deep learning image reconstruction (DLIR) and conventional fast spin-echo T2WI with DLIR for evaluating pancreatic protocol.

Methods: This retrospective study included 42 patients (mean age, 70.2 years) with pancreatic cancer who underwent gadoxetic acid-enhanced MRI.

View Article and Find Full Text PDF

The molecular mechanisms underpinning the development of metachronous tumors in the remnant bile duct following surgical resection of primary biliary tract carcinomas (BTCs) are unknown. This study aimed to elucidate these mechanisms by evaluating the clinicopathologic features of BTCs, the alterations to 31 BTC-related genes on targeted sequencing, and the aberrant expression of p53, p16, SMAD4, ARID1A and β-catenin on immunohistochemistry. Twelve consecutive patients who underwent resection of metachronous BTCs following primary BTC resection with negative bile duct margins were enrolled.

View Article and Find Full Text PDF

We developed a broadband two-layer anti-reflection (AR) coating for use on a sapphire half-wave plate (HWP) and an alumina infrared (IR) filter for the cosmic microwave background (CMB) polarimetry. Measuring the faint CMB B-mode signals requires maximizing the number of photons reaching the detectors and minimizing spurious polarization due to reflection with an off-axis incident angle. Sapphire and alumina have high refractive indices of 3.

View Article and Find Full Text PDF

Many modern millimeter and submillimeter ("mm-wave") telescopes for astronomy are deploying more detectors by increasing the detector pixel density and, with the rise of lithographed detector architectures and high-throughput readout techniques, it is becoming increasingly practical to overfill the focal plane. However, when the pixel pitch is small compared to the product of the wavelength and the focal ratio , or ≲1.2 , the Bose term of the photon noise correlates between neighboring detector pixels due to the Hanbury Brown and Twiss (HBT) effect.

View Article and Find Full Text PDF

We present the requirements, design, and evaluation of the cryogenic continuously rotating half-wave plate (CHWP) for the Simons Observatory (SO). SO is a cosmic microwave background polarization experiment at Parque Astronómico de Atacama in northern Chile that covers a wide range of angular scales using both small (⌀0.42 m) and large (⌀6 m) aperture telescopes.

View Article and Find Full Text PDF

Our study was designed to examine the correlation between single nucleotide polymorphism (SNP) in the endoplasmic reticulum aminopeptidase 1 (ERAP1) gene, specifically focusing on rs27434, and plural tissue weight. We conducted this investigation using autopsy samples from the Japanese population. Blood samples were collected from 178 Japanese subjects who had undergone autopsies in Shimane Prefecture.

View Article and Find Full Text PDF
Article Synopsis
  • The new calibration system for cosmic microwave background (CMB) polarization uses a sparse wire grid to reflect polarized light, improving accuracy in measurements.
  • A remote-controlled feature allows for regular calibration, which was previously not possible, utilizing electric actuators to adjust the wire grid's position.
  • The system includes a motor for rotation and sensors to ensure precise monitoring, resulting in minimal systematic errors and planned installation in telescopes at Simons Observatory.
View Article and Find Full Text PDF
Article Synopsis
  • - This study investigated the relationship between the severity of contrast extravasation (CE) seen on CT scans and the need for massive transfusions (MT) in children with blunt liver and/or spleen injuries, over a span from 2008 to 2019.
  • - The research included 1,407 pediatric patients, revealing that 14% required MT, and specific types of CE, particularly intraparenchymal and into the peritoneal cavity, significantly correlated with increased transfusion needs.
  • - The findings suggest that recognizing active CE during initial CT scans can guide healthcare providers in making informed decisions about transfusion strategies for young patients with these types of injuries.
View Article and Find Full Text PDF

Background/aim: Pancreatic adenocarcinoma (PDAC) with synchronous oligometastases may indicate a surgical benefit after chemotherapy. We investigated whether primary and metastatic resection of PDAC with oligometastases can improve the survival and then explored prognostic factors to identify indications for conversion surgery.

Patients And Methods: We reviewed 425 patients with PDAC who underwent pancreatic resection from 2005 to 2019.

View Article and Find Full Text PDF

Background: Zooplankton plays an important role in the marine ecosystem. A high level of taxonomic expertise is necessary for accurate species identification based on morphological characteristics. As an alternative method to morphological classification, we focused on a molecular approach using 18S and 28S ribosomal RNA (rRNA) gene sequences.

View Article and Find Full Text PDF

Objectives: To elucidate the prognostic impact of sarcopenia before and after neoadjuvant chemotherapy (NAC) for pancreatic cancer (PC).

Methods: We retrospectively studied 75 consecutive PC patients who underwent neoadjuvant gemcitabine plus S-1 combination therapy followed by pancreatectomy between 2008 and 2016. According to the skeletal muscle volume index (SMI), the patients were divided into the muscle attenuation group (MAG) and normal group (NG) before or after NAC.

View Article and Find Full Text PDF

Objectives: To investigate the effect of deep learning image reconstruction (DLIR) on the accuracy of iodine quantification and image quality of dual-energy CT (DECT) compared to that of other reconstruction algorithms in a phantom experiment and an abdominal clinical study.

Methods: An elliptical phantom with five different iodine concentrations (1-12 mgI/mL) was imaged five times with fast-kilovoltage-switching DECT for three target volume CT dose indexes. All images were reconstructed using filtered back-projection, iterative reconstruction (two levels), and DLIR algorithms.

View Article and Find Full Text PDF

We performed the accurate diagnosis and complete surgical resection of a gastrointestinal stromal tumor at the mesentery of the small bowel. Computed tomography (CT) in a 62-year-old man at 2 years after gastrectomy for gastric cancer showed a mesenteric tumor, with no other tumors noted. Positron emission tomography-computed tomography (PET-CT) showed a maximum standardized uptake value (SUV max) of 2.

View Article and Find Full Text PDF

We present the design and measured performance of a new carbon fiber strut design that is used in a cryogenically cooled truss for the Simons Observatory small aperture telescope. The truss consists of two aluminum 6061 rings separated by 24 struts. Each strut consists of a central carbon fiber tube fitted with two aluminum end caps.

View Article and Find Full Text PDF

Objectives: To evaluate the effect of 6-cycle completion and earlier use of radium-233 dichloride (Ra223) on the prognosis of patients with metastatic castration-resistant prostate cancer (mCRPC).

Methods: We retrospectively evaluated 75 patients with bone metastases-predominant mCRPC who were treated with Ra223 between August 2016 and August 2021. The primary purpose of the study was to assess the effect of Ra223 completion (6 cycles) on patient prognosis, and the secondary purpose was to investigate factors associated with Ra223 incompletion (fewer than 6 cycles) and overall survival.

View Article and Find Full Text PDF

Purpose: For whole-breast irradiation after breast-conserving surgery, computed tomography simulation (CTS) and irradiation are generally performed during free breathing. In treatment planning, there are three techniques: field-in-field (FIF), physical wedge (PW), and enhanced dynamic wedge (EDW). The aim of this study was to investigate the impact of respiratory motion on doses for these three irradiation techniques.

View Article and Find Full Text PDF

Controlling stray light at millimeter wavelengths requires special optical design and selection of absorptive materials that should be compatible with cryogenic operating environments. While a wide selection of absorptive materials exists, these typically exhibit high indices of refraction and reflect/scatter a significant fraction of light before absorption. For many lower index materials such as commercial microwave absorbers, their applications in cryogenic environments are challenging.

View Article and Find Full Text PDF

We introduced a conformational sampling method in an earlier report: The multi-dimensional virtual-system coupled molecular dynamics (mD-VcMD) enhances conformational sampling of a biomolecular system by computer simulations. Herein, new sampling method, a subzone-based mD-VcMD, is presented as an extension of mD-VcMD. Then, the subzone-based method is extended further using a genetic algorithm (GA) named the GA-guided mD-VcMD.

View Article and Find Full Text PDF

Objective: To evaluate temporal trends in neoadjuvant chemotherapy (NAC) utilisation and outcomes in patients with locally advanced upper tract urothelial carcinoma (UTUC).

Patients And Methods: We included 289 patients from seven hospitals who underwent radical nephroureterectomy (RNU) for locally advanced UTUC (≥cT3 or cN+) between 2000 and 2020. These patients received RNU alone or two to four courses of NAC with either a cisplatin- or carboplatin-based regimen.

View Article and Find Full Text PDF