Lipid nanoparticles are a generic type of nanomaterial with broad applicability in medicine as drug delivery vehicles. Liposomes are a subtype of lipid nanoparticles and, as a therapeutic platform, can be loaded with a genetic material or pharmaceutical agents for use as drug treatments. An open question for these types of lipid nanoparticles is what factor(s) affect the long-term stability of the particles.
View Article and Find Full Text PDFACS Appl Mater Interfaces
December 2022
Sensing biomarkers in exhaled breath offers a potentially portable, cost-effective, and noninvasive strategy for disease diagnosis screening and monitoring, while high sensitivity, wide sensing range, and target specificity are critical challenges. We demonstrate a deep learning-assisted plasmonic sensing platform that can detect and quantify gas-phase biomarkers in breath-related backgrounds of varying complexity. The sensing interface consisted of Au/SiO nanopillars covered with a 15 nm metal-organic framework.
View Article and Find Full Text PDFNanomaterials (Basel)
September 2022
The number of techniques to measure number concentrations and size distributions of submicrometer particles has recently increased. Submicrometer particle standards are needed to improve the accuracy and reproducibility of these techniques. The number concentrations of fluorescently labeled polystyrene submicrometer sphere suspensions with nominal 100 nm, 200 nm and 500 nm diameters were measured using seven different techniques.
View Article and Find Full Text PDFThis study demonstrates that commonly used consumer products such as single-use food grade nylon bags and hot beverage cups lined with low-density polyethylene release nanometer-sized plastic particles at number densities >10 L when exposed to water. The number of particles released was a function of the initial water temperature (high temperature vs ambient) for each of the tested materials. Mean particle diameters were between 30 and 80 nm with few particles >200 nm.
View Article and Find Full Text PDFThe measurement of polydisperse protein aggregates and particles in biotherapeutics remains a challenge, especially for particles with diameters of ≈ 1 µm and below (sub-micrometer). This paper describes an interlaboratory comparison with the goal of assessing the measurement variability for the characterization of a sub-micrometer polydisperse particle dispersion composed of five sub-populations of poly(methyl methacrylate) (PMMA) and silica beads. The study included 20 participating laboratories from industry, academia, and government, and a variety of state-of-the-art particle-counting instruments.
View Article and Find Full Text PDFA plasmonic sensing platform was developed as a noninvasive method to monitor gas-phase biomarkers related to cystic fibrosis (CF). The nanohole array (NHA) sensing platform is based on localized surface plasmon resonance (LSPR) and offers a rapid data acquisition capability. Among the numerous gas-phase biomarkers that can be used to assess the lung health of CF patients, acetaldehyde was selected for this investigation.
View Article and Find Full Text PDFOnline water bioburden analyzers (OWBAs) can provide real-time feedback on viable bacteria in high-purity water (HPW) systems for pharmaceutical manufacturers. To calibrate and validate OWBAs, which detect bacteria using scattered light and bacterial autofluorescence, standards are needed that mimic the characteristics of bacteria in HPW. To guide selection of potential standards, e.
View Article and Find Full Text PDFThe present work demonstrates development of a miniaturized plasmonic platform comprised of a Au nanohole array (NHA) on a Si/Si3N4 substrate. Plasmonic responses of the NHA platform, which is coated with Cu-benzenetricarboxylate metal organic framework (MOF), are found to be promising even towards 500 nmol mol-1 (ppb) of acetone or ethanol vapors at room temperature. The sensing characteristics are further investigated by varying the operating temperature (296 K to 318 K) of the sensor and the concentrations of vapors (500 nmol mol-1 to 320 μmol mol-1).
View Article and Find Full Text PDFNanoparticle tracking analysis (NTA) obtains particle size by analysis of particle diffusion through a time series of micrographs and particle count by a count of imaged particles. The number of observed particles imaged is controlled by the scattering cross-section of the particles and by camera settings such as sensitivity and shutter speed. Appropriate camera settings are defined as those that image, track, and analyze a sufficient number of particles for statistical repeatability.
View Article and Find Full Text PDFA number of sensing technologies, using a variety of transduction principles, have been proposed for non-invasive chemical sensing. A fundamental problem common to all these sensing technologies is determining what features of the transducer's signal constitute a chemical fingerprint that allows for precise analyte recognition. Of particular importance is the need to extract features that are robust with respect to the sensor's age or stimulus intensity.
View Article and Find Full Text PDFThe motivation behind this work is to study the gas phase chemical sensing characteristics of optical (plasmonic) nano-antennas (ONA) and graphene/graphene oxide-covered versions of these structures. ONA are devices that have their resonating frequency in the visible range. The basic principle governing the detection mechanism for ONA is refractive index sensing.
View Article and Find Full Text PDFPerformance characteristics of gas-phase microsensors will determine the ultimate utility of these devices for a wide range of chemical monitoring applications. Commonly employed chemiresistor elements are quite sensitive to selected analytes, and relatively new methods have increased the selectivity to specific compounds, even in the presence of interfering species. Here, we have focused on determining whether purposefully driven temperature modulation can produce faster sensor-response characteristics, which could enable measurements for a broader range of applications involving dynamic compositional analysis.
View Article and Find Full Text PDFMonitoring of chemical species in breath offers an approach for the detection of disease and other conditions that cause homeostatic imbalance. Here, we demonstrate the use of microsensor-based devices for detecting select biomarkers in simulated exhaled breath as a step toward enabling fast and inexpensive breath-screening technology. Microhotplate elements functionalized with three chemiresistive metal-oxide films (SnO(2), In(2)O(3), and CuO) were used to acquire data in simulated breath containing single targets [(5 to 20) μmol/mol ammonia, methanol, and acetone], as well as mixtures of those species.
View Article and Find Full Text PDFThe selectivity of a chemiresistive gas sensor comprising an array of single-crystalline tin oxide nanowires (NWs) is shown to be greatly enhanced by combined temperature and gate voltage modulation. This dual modulation was effected by a novel microsensor platform that consisted of a suspended nitride membrane embedded with independently addressable platinum heater and back-gate structures. The sensor was evaluated in a chemical vapor exposure test consisting of three volatile organic compound (VOC) analytes in an air background; VOC concentrations ranged from 20 μmol/mol to 80 μmol/mol.
View Article and Find Full Text PDFArtificial olfaction is a potential tool for noninvasive chemical monitoring. Application of "electronic noses" typically involves recognition of "pretrained" chemicals, while long-term operation and generalization of training to allow chemical classification of "unknown" analytes remain challenges. The latter analytical capability is critically important, as it is unfeasible to pre-expose the sensor to every analyte it might encounter.
View Article and Find Full Text PDFA series of C- and Z-shaped complexes of the form cis- and trans-[Re(CO)3(L)]2BiBzIm, where L = 4-phenylpyridine, 2,4'-bipyridine, or pyridine and BiBzIm = 2,2'-bisbenzimidizolate, have been synthesized by the reaction of [Re(CO)4]2BiBzIm with a slight excess of L in refluxing tetrahydrofuran. Five of the six compounds have been isolated and crystallographically and electrochemically characterized. Formation of the sixth, the cis form of the [Re(CO)3(4-phenylpyridine)]2BiBzIm, is evidently inhibited by the torsional steric demands of proximal 4-phenylpyridines.
View Article and Find Full Text PDFThe light harvesting efficiency of dye-sensitized photoelectrodes was enhanced by coupling a TiO(2) photonic crystal layer to a conventional film of TiO(2) nanoparticles. In addition to acting as a dielectric mirror, the inverse opal photonic crystal caused a significant change in dye absorbance which depended on the position of the stop band. Absorbance was suppressed at wavelengths shorter than the stop band maximum and was enhanced at longer wavelengths.
View Article and Find Full Text PDFMicroporous thin films (approximately equal to 50 to 400 nm) composed of discrete, cavity-containing molecular rectangles have been prepared. The films, which contain both amorphous and microcrystalline domains, display shape-selective transport behavior. They are permeable to small molecules and to molecules that are short or narrow in at least one dimension--for example, elongated planar molecules--but are impermeable to molecules lacking a narrow dimension.