Radiat Prot Dosimetry
April 2017
The International Commission on Radiological Protection (ICRP) has established Task Group 94 (TG 94) to develop a publication on the ethical foundations of the system of radiological protection aiming to consolidate the basis of ICRP's recommendations, to improve the understanding of the system and to provide a basis for communication on radiation risk and its perception. Through the review of the publications of the Commission and the conduct of a series of workshops, TG 94 has identified the key components of the ethical theories and principles relevant to the system of radiological protection. The purpose of eliciting the ethical values underpinning the system of radiological protection is not only to clarify the rationale of the recommendations made by the Commission, but also to assist in discussions related to its practical implementation.
View Article and Find Full Text PDFIn a previous study, we constructed a male reference Korean phantom; HDRK-Man (High-Definition Reference Korean-Man), to represent Korean adult males for radiation protection purposes. In the present study, a female phantom; HDRK-Woman (High-Definition Reference Korean-Woman), was constructed to represent Korean adult females. High-resolution color photographic images obtained by serial sectioning of a 26 year-old Korean adult female cadaver were utilized.
View Article and Find Full Text PDFEven though the hybrid phantom embodies both the anatomic reality of voxel phantoms and the deformability of stylized phantoms, it must be voxelized to be used in a Monte Carlo code for dose calculation or some imaging simulation, which incurs the inherent limitations of voxel phantoms. In the present study, a voxel phantom named VKH-Man (Visible Korean Human-Man), was converted to a polygon-surface phantom (PSRK-Man, Polygon-Surface Reference Korean-Man), which was then adjusted to the Reference Korean data. Subsequently, the PSRK-Man polygon phantom was directly, without any voxelization process, implemented in the Geant4 Monte Carlo code for dose calculations.
View Article and Find Full Text PDFRadiat Prot Dosimetry
November 2011
The objective of this study is the systematic and individual assessment of the annual effective dose due to inhaled radon for the Seoul Subway Police officers, Korea. The annual average radon concentrations were found to be in the range of 18.9-114 Bq·m(-3) in their workplaces.
View Article and Find Full Text PDFThis study attempted to validate a new method for patient-tailored efficiency calibration. Digital calibration with Monte Carlo simulations was used to substitute the lack of precision limitation due to the limited number of experimental phantoms in whole body counting calibration for internal dosimetry. The validity of this approach was examined by comparing the simulation results to the measured values from actual measurements using family BOMAB phantoms.
View Article and Find Full Text PDFRadiat Prot Dosimetry
February 2010
Quantification of radioactivity in the body by in vivo bioassay uses counting efficiencies obtained from calibration from a phantom. Usually a standardised BOMAB (Bottle Manikin Absorption) phantom is employed for whole-body counting. The physical size of workers being counted, however, may differ from the calibration phantom, and can be a source of significant errors in dose estimates.
View Article and Find Full Text PDFThe International Commission on Radiological Protection (ICRP) published the new recommendations 2007 on radiological protection. International Atomic Energy Agency (IAEA) is also under process in revising its International Basic Safety (BSS). According to revision of the ICRP recommendations and BSS, the Korean government plans to implement those changes.
View Article and Find Full Text PDF