In radiotherapy, when photon energy exceeding 8 MV is utilized, photoneutrons can activate the components within the gantry of the linear accelerator (linac). At the end of the linac's lifecycle, radiation workers are tasked with its dismantling and disposal, potentially exposing them to unintentional radiation. This study aims to identify and measure the radioisotopes generated by this activation through spectroscopy, and to evaluate the effective dose rate.
View Article and Find Full Text PDFAlthough research into ultrahigh dose-rate (UHDR) radiation therapy is ongoing, there is a significant lack of experimental measurements for two-dimensional (2D) dose-rate distributions. Additionally, conventional pixel-type detectors result in significant beam loss. In this study, we developed a pixel array-type detector with adjustable gaps and a data acquisition system to evaluate its effectiveness in measuring UHDR proton beams in real time.
View Article and Find Full Text PDFPre-treatment patient-specific quality assurance (QA) is critical to prevent radiation accidents. The electronic portal imaging device (EPID) is a dose measurement tool with good resolution and a low volume-averaging effect. EPIbeam—an EPID-based portal dosimetry software—has been newly installed in three institutions in Korea.
View Article and Find Full Text PDFPhosphor screens have attracted increasing global interest because they can aid the acquisition of high-quality images while simultaneously reducing exposure. However, although increasing the thickness of the phosphor screen increases exposure efficiency due to scattered light, it also leads to a broader light spread, which results in poorer resolution. Hence, in this study, we implemented a reflector using a mirror-coating technique on the surface of a phosphor screen and analyzed its characteristics in terms of luminescence intensity and resolution.
View Article and Find Full Text PDFObjective: The Korean Radiation Oncology Group (12-02) investigated the outcome of stereotactic ablative radiotherapy for hepatocellular carcinoma ≤5 cm using 60 Gy in three fractions. To evaluate dosimetric differences and compliance in a multicenter trial, a planning dummy run procedure was performed.
Methods: All six participating institutions were provided the contours of two dummy run cases.
A diagnostic multileaf collimator (MLC) was developed for diagnostic radiography dose reduction. Optically stimulated luminescent dosemeters (OSLDs) were used to evaluate the efficacy of this device for dental radiography cephalometric exposure reduction. The OSLD dosimetric characteristics for 80 kVp cephalometric exposure were first obtained.
View Article and Find Full Text PDFPurpose: To compare volumetric modulated arc therapy of RapidArc with robotic stereotactic body radiation therapy (SBRT) of CyberKnife in the planning and delivery of SBRT for hepatocellular carcinoma (HCC) treatment by analyzing dosimetric parameters.
Materials And Methods: Two radiation treatment plans were generated for 29 HCC patients, one using Eclipse for the RapidArc plan and the other using Multiplan for the CyberKnife plan. The prescription dose was 60 Gy in 3 fractions.
This study evaluated the incidence of hepatic toxicity after stereotactic ablative radiotherapy (SABR) using 3 fractions to the liver, and identified the predictors for hepatic toxicity. We retrospectively reviewed 78 patients with primary and metastatic liver cancers, who underwent SABR using 3 fractions between 2003 and 2011. To examine the incidence of hepatic toxicity, we defined newly developed hepatic toxicity≥grade 2 according to the National Cancer Institute Common Terminology Criteria for Adverse Events v4.
View Article and Find Full Text PDFWe retrospectively reviewed 88 patients with oligometases in the para-aortic region from any controlled primary tumor site who were treated with stereotactic body radiotherapy (SBRT). The 5-year local control, disease-free survival, and overall survival rates were 83%, 31%, and 41%, respectively. A 90% tumor-control probability was predicted at a biological effective dose of 90 Gy.
View Article and Find Full Text PDFPurpose: To report the results of stereotactic body radiotherapy (SBRT) for unresectable primary or recurrent cholangiocarcinoma.
Materials And Methods: From January 2005 through August 2013, 58 patients with unresectable primary (n = 28) or recurrent (n = 30) cholangiocarcinoma treated by SBRT were retrospectively analyzed. The median prescribed dose was 45 Gy in 3 fractions (range, 15 to 60 Gy in 1-5 fractions).
This work proposes the basic reference data of occupational dose management and statistical dose distribution with the classification of radiation work groups though analysis of occupational dose distribution. Data on occupational radiation exposure from medical and scientific usage of radiation in Korea Institute of Radiological and Medical Sciences for the years 2002-11 are presented and evaluated with the characteristic tendency of radiation working groups. The results of occupational radiation exposure were measured by personal dosemeters.
View Article and Find Full Text PDFPurpose: The purpose of this study is to identify the predictors for severe intestinal toxicity (IT) in patients with abdominopelvic malignancies treated with three fractions of stereotactic ablative radiotherapy (SABR).
Methods: From 2001 to 2011, 202 patients with abdominopelvic malignancies were treated with curative-intent SABR. Among these, we retrospectively reviewed the clinical records of 55 patients with the presence of the intestine that received a dose ≥20 % of the prescribed dose.
The purpose of this study was to assess the feasibility and efficacy of stereotactic ablative radiotherapy (SABR) for liver tumor in patients with Barcelona Clinic Liver Cancer (BCLC)-C stage hepatocellular carcinoma (HCC). We retrospectively reviewed the medical records of 35 patients between 2003 and 2011. Vascular invasion was diagnosed in 32 patients, extrahepatic metastases in 11 and both in 8.
View Article and Find Full Text PDFBackground: The objective of this study was to evaluate the efficacy and safety of stereotactic body radiation therapy (SBRT) as a local salvage treatment after incomplete transarterial chemoembolization (TACE) for inoperable hepatocellular carcinoma (HCC).
Methods: The main eligibility criteria were a greatest tumor dimension (LD sum) <10 cm, inoperable HCC, and incomplete response after TACE. Prescribed SBRT doses were up to 60 gray (Gy) in 3 fractions, but doses were reduced until normal tissue constraints were allowed.
The authors reviewed their experiences of external beam radiotherapy (EBR) as an initial treatment in retinoblastoma patients to determine its long-term effect on subsequent tumor control and complications. A total of 32 eyes in 25 patients that underwent EBR for retinoblastoma were reviewed retrospectively. The patients consisted of 21 boys and 4 girls of median age at treatment of 7.
View Article and Find Full Text PDFObjective: Study aims include determination of nationwide structural characteristics of radiation oncology facilities, types of radiation therapy equipment, availability of human resources and trends and comparisons with previous surveys.
Methods: An annual nationwide survey was conducted to collect the statistics of infrastructure since 1997. All requested questionnaires have been identical for 10 years.