Background: Consumer products such as electrical shavers exert a combination of dynamic loading in the form of pressure and shear on the skin. This mechanical stimulus can lead to discomfort and skin tissue responses characterised as "Skin Sensitivity". To minimise discomfort following shaving, there is a need to establish specific stimulus-response relationships using advanced tools such as optical coherence tomography (OCT).
View Article and Find Full Text PDFBackground: Skin sensitivity (SS) is a commonly occurring response to a range of stimuli, including environmental conditions (e.g., sun exposure), chemical irritants (e.
View Article and Find Full Text PDFObjectives: Deconvolution-derived maps of CT perfusion (CTP) data may be confounded by transit delays. We propose temporal similarity perfusion (TSP) analysis to decrease CTP maps' dependence on transit times and investigate its sensitivity to detect perfusion deficits.
Methods: CTP data of acute stroke patients obtained within 9 h of symptom onset was analyzed using a delay-insensitive singular value decomposition method and with TSP.
In patient-specific mathematical models of cardiac electromechanics, usually a patient-specific geometry and a generic myofiber orientation field are used as input, upon which myocardial tissue properties are tuned to clinical data. It remains unclear to what extent deviations in myofiber orientation and geometry between model and patient influence model predictions on cardiac function. Therefore, we evaluated the sensitivity of cardiac function for geometry and myofiber orientation in a biventricular (BiV) finite element model of cardiac mechanics.
View Article and Find Full Text PDFBackground: The purpose of this systematic review was to determine the significance of the grade of dysplasia in the development of invasive carcinoma.
Methods: A systematic search was performed to identify all relevant evidence. Titles and abstracts were screened using predefined criteria.
Background: Combined measurement of electrical activation and mechanical dyssynchrony in heart failure (HF) patients is scarce but may contain important mechanistic and diagnostic clues.
Objective: The purpose of this study was to characterize the electromechanical (EM) coupling in HF patients with prolonged QRS duration.
Methods: Ten patients with QRS width >120 ms underwent left ventricular (LV) electroanatomic contact mapping using the Noga® XP system (Biosense Webster).
Situs inversus totalis (SIT) is characterized by complete mirroring of gross cardiac anatomy and position combined with an incompletely mirrored myofiber arrangement, being normal at the apex but inverted at the base of the left ventricle (LV). This study relates myocardial structure to mechanical function by analyzing and comparing myocardial deformation patterns of normal and SIT subjects, focusing especially on circumferential-radial shear. In nine control and nine SIT normotensive human subjects, myocardial deformation was assessed from magnetic resonance tagging (MRT) image sequences of five LV short-axis slices.
View Article and Find Full Text PDFAims: Left-ventricular (LV) conduction disturbances are common in heart-failure patients and a left bundle-branch block (LBBB) electrocardiogram (ECG) type is often seen. The precise cause of this pattern is uncertain and is probably variable between patients, ranging from proximal interruption of the left bundle branch to diffuse distal conduction disease in the working myocardium. Using realistic numerical simulation methods and patient-tailored model anatomies, we investigated different hypotheses to explain the observed activation order on the LV endocardium, electrogram morphologies, and ECG features in two patients with heart failure and LBBB ECG.
View Article and Find Full Text PDFIn ureter peristalsis, the orientation of the contracting smooth muscle cells is essential, yet current descriptions of orientation and composition of the smooth muscle layer in human as well as in rat ureter are inconsistent. The present study aims to improve quantification of smooth muscle orientation in rat ureters as a basis for mechanistic understanding of peristalsis. A crucial step in our approach is to use two-photon laser scanning microscopy and image analysis providing objective, quantitative data on smooth muscle cell orientation in intact ureters, avoiding the usual sectioning artifacts.
View Article and Find Full Text PDFIt has been hypothesized that myofiber orientation adapts to achieve a preferred mechanical loading state in the myocardial tissue. Earlier studies tested this hypothesis in a combined model of left ventricular (LV) mechanics and remodeling of myofiber orientation in response to fiber cross-fiber shear, assuming synchronous timing of activation and uniaxial active stress development. Differences between computed and measured patterns of circumferential-radial shear strain E(cr) were assumed to be caused by limitations in either the LV mechanics model or the myofiber reorientation model.
View Article and Find Full Text PDFCreation of an arteriovenous fistula (AVF) for hemodialysis may result in cardiac failure due to dramatic increases in cardiac output. To investigate the quantitative relations between AVF flow, changes in cardiac output, myocardial stress and strain and resulting left ventricular adaptation, a computational model is developed. The model combines a one-dimensional pulse wave propagation model of the arterial network with a zero-dimensional one-fiber model of cardiac mechanics and includes adaptation rules to capture the effect of the baro-reflex and long-term structural remodelling of the left ventricle.
View Article and Find Full Text PDFThe left ventricle (LV) of mammals with Situs Solitus (SS, normal organ arrangement) displays hardly any interindividual variation in myofiber pattern and experimentally determined torsion. SS LV myofiber pattern has been suggested to result from adaptive myofiber reorientation, in turn leading to efficient pump and myofiber function. Limited data from the Situs Inversus Totalis (SIT, a complete mirror image of organ anatomy and position) LV demonstrated an essential different myofiber pattern, being normal at the apex but mirrored at the base.
View Article and Find Full Text PDFA computational method of reduced complexity is developed for simulating vascular hemodynamics by combination of one-dimensional (1D) wave propagation models for the blood vessels with zero-dimensional (0D) lumped models for the microcirculation. Despite the reduced dimension, current algorithms used to solve the model equations and simulate pressure and flow are rather complex, thereby limiting acceptance in the medical field. This complexity mainly arises from the methods used to combine the 1D and the 0D model equations.
View Article and Find Full Text PDFIntroduction: Inadequate flow enhancement on the one hand, and excessive flow enhancement on the other hand, remain frequent complications of arteriovenous fistula (AVF) creation, and hamper hemodialysis therapy in patients with end-stage renal disease. In an effort to reduce these, a patient-specific computational model, capable of predicting postoperative flow, has been developed. The purpose of this study was to determine the accuracy of the patient-specific model and to investigate its feasibility to support decision-making in AVF surgery.
View Article and Find Full Text PDFPLoS Comput Biol
February 2012
Geometry of the heart adapts to mechanical load, imposed by pressures and volumes of the cavities. We regarded preservation of cardiac geometry as a homeostatic control system. The control loop was simulated by a chain of models, starting with geometry of the cardiac walls, sequentially simulating circulation hemodynamics, myofiber stress and strain in the walls, transfer of mechano-sensed signals to structural changes of the myocardium, and finalized by calculation of resulting changes in cardiac wall geometry.
View Article and Find Full Text PDFThe preferred vascular access for hemodialysis is an autologous arteriovenous fistula (AVF) in the arm: a surgically created connection between an artery and vein. The surgeon selects the AVF location based on experience and preoperative diagnostics. However, 20-50% of all lower arm AVFs are hampered by a too low access flow, whereas complications associated with too high flows are observed in 20% of all upper arm AVFs.
View Article and Find Full Text PDFMathematical models of cardiac mechanics can potentially be used to relate abnormal cardiac deformation, as measured noninvasively by ultrasound strain rate imaging or magnetic resonance tagging (MRT), to the underlying pathology. However, with current models, the correct prediction of wall shear strain has proven to be difficult, even for the normal healthy heart. Discrepancies between simulated and measured strains have been attributed to 1) inadequate modeling of passive tissue behavior, 2) neglecting active stress development perpendicular to the myofiber direction, or 3) neglecting crossover of myofibers in between subendocardial and subepicardial layers.
View Article and Find Full Text PDFBiomech Model Mechanobiol
August 2009
As an initial step to investigate stimulus-response relations in growth and remodeling (G&R) of cardiac tissue, this study aims to develop a method to simulate 3D-inhomogeneous volumetric growth. Growth is regarded as a deformation that is decomposed into a plastic component which describes unconstrained growth and an elastic component to satisfy continuity of the tissue after growth. In current growth models, a single reference configuration is used that remains fixed throughout the entire growth process.
View Article and Find Full Text PDFDeformation and structure of the cardiac wall can be assessed non-invasively by imaging techniques such as magnetic resonance imaging. Understanding the (patho-)physiology that underlies the observed deformation and structure is critical for clinical diagnosis. However, much about the genesis of deformation and structure is unknown.
View Article and Find Full Text PDFAm J Physiol Heart Circ Physiol
July 2008
In 1926, the famous American pediatric cardiologist, Dr. Helen B. Taussig, observed that in situs inversus totalis (SIT) main gross anatomical structures and the deep muscle bundles of the ventricles were a mirror image of the normal structure, while the direction of the superficial muscle bundles remained unchanged (H.
View Article and Find Full Text PDFMathematical models provide a suitable platform to test hypotheses on the relation between local mechanical stimuli and responses to cardiac structure and geometry. In the present model study, we tested hypothesized mechanical stimuli and responses in cardiac adaptation to mechanical load on their ability to estimate a realistic myocardial structure of the normal and situs inversus totalis (SIT) left ventricle (LV). In a cylindrical model of the LV, 1) mass was adapted in response to myofiber strain at the beginning of ejection and to global contractility (average systolic pressure), 2) cavity volume was adapted in response to fiber strain during ejection, and 3) myofiber orientations were adapted in response to myofiber strain during ejection and local misalignment between neighboring tissue parts.
View Article and Find Full Text PDFProg Biophys Mol Biol
September 2008
Occasionally, individuals have a complete, mirror-image reversal of their internal organ position, called situs inversus totalis (SIT). Whereas gross anatomy is mirror-imaged in SIT, this might not be the case for the internal architecture of organs, e.g.
View Article and Find Full Text PDFGenetic variation is described at 15 loci in 2 neotenic and 12 nonneotenic populations of red-spotted newts. Though high levels of genetic similarity (I = 0.990) were found among all populations, allele frequencies at six of the eight most polymorphic loci show significant heterogeneity across populations.
View Article and Find Full Text PDFAppl Environ Microbiol
May 1984
Eight waterworks in The Netherlands, which use surface water as their raw water source, were sampled repeatedly between November 1978 and June 1981. At five waterworks , 30 of 45 samples of raw water contained viruses. Of 55 samples of partially purified water, 11 were virus positive, including 8 after coagulation, sedimentation, and rapid sand filtration, 2 after storage, coagulation, sedimentation, transport chlorination, and rapid sand filtration, and 1 after storage in open reservoirs for 5 months.
View Article and Find Full Text PDF