Publications by authors named "Kronfeld A"

Objectives: The aim of this study was to investigate the occurrence of motion artifacts and image quality of brain magnetic resonance imaging (MRI) T1-weighted imaging applying 3D motion correction via the Scout Accelerated Motion Estimation and Reduction (SAMER) framework compared with conventional T1-weighted imaging at 1.5 T.

Materials And Methods: A preliminary study involving 14 healthy volunteers assessed the impact of the SAMER framework on induced motion during 3 T MRI scans.

View Article and Find Full Text PDF

Background: Several factors are frequently considered for outcome prediction rin stroke patients. We assessed the value of digital subtraction angiography (DSA)-based brain perfusion measurements after mechanical thrombectomy (MT) for outcome prediction in acute ischaemic stroke.

Methods: From DSA image data (n = 90; 38 females; age 73.

View Article and Find Full Text PDF

Purpose: To examine the impact of deep learning-augmented contrast enhancement on image quality and diagnostic accuracy of poorly contrasted CT angiography in patients with suspected stroke.

Methods: This retrospective single-centre study included 102 consecutive patients who underwent CT imaging for suspected stroke between 01/2021 and 12/2022, including whole brain volume perfusion CT (VPCT) and, specifically, a poorly contrasted CT angiography (defined as < 350HU in the proximal MCA). CT angiography imaging data was reconstructed using i.

View Article and Find Full Text PDF

Diffusion-based tractography in the optic nerve requires sampling strategies assisted by anatomical landmark information (regions of interest [ROIs]). We aimed to investigate the feasibility of expert-placed, high-resolution T1-weighted ROI-data transfer onto lower spatial resolution diffusion-weighted images. Slab volumes from 20 volunteers were acquired and preprocessed including distortion bias correction and artifact reduction.

View Article and Find Full Text PDF

To evaluate the effect of a vendor-agnostic deep learning denoising (DLD) algorithm on diagnostic image quality of non-contrast cranial computed tomography (ncCT) across five CT scanners.This retrospective single-center study included ncCT data of 150 consecutive patients (30 for each of the five scanners) who had undergone routine imaging after minor head trauma. The images were reconstructed using filtered back projection (FBP) and a vendor-agnostic DLD method.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to evaluate the effectiveness and quality of accelerated brain diffusion-weighted imaging (DWI) using deep learning technologies.
  • 85 patients underwent MRI, where different imaging techniques were compared, including conventional and those enhanced by deep learning, with experienced reviewers assessing the results.
  • The findings indicated that deep learning DWI markedly improved image quality and diagnostic confidence over traditional methods, making ultra-fast brain imaging feasible and more effective.
View Article and Find Full Text PDF

Emerging from the development of single-energy Computed Tomography (CT) and Dual-Energy Computed Tomography, Multi-Energy Computed Tomography (MECT) is a promising tool allowing advanced material and tissue decomposition and thereby enabling the use of multiple contrast materials in preclinical research. The scope of this work was to evaluate whether a usual preclinical micro-CT system is applicable for the decomposition of different materials using MECT together with a matrix-inversion method and how different changes of the measurement-environment affect the results. A matrix-inversion based algorithm to differentiate up to five materials (iodine, iron, barium, gadolinium, residual material) by applying four different acceleration voltages/energy levels was established.

View Article and Find Full Text PDF

Acute strokes can affect heart rate variability (HRV), the mechanisms how are not well understood. We included 42 acute stroke patients (2-7 days after ischemic stroke, mean age 66 years, 16 women). For analysis of HRV, 20 matched controls (mean age 60.

View Article and Find Full Text PDF

Objective: To evaluate diagnostic image quality of ultra-high-resolution computed tomography angiography (UHR-CTA) in neurovascular imaging as compared to normal resolution CT-angiography (NR-CTA).

Material And Methods: In this retrospective single-center study brain and neck CT-angiography was performed using an ultra-high-resolution computed tomography scanner (n = 82) or a normal resolution CT scanner (NR-CTA; n = 73). Ultra-high-resolution images were reconstructed with a 1024 × 1024 matrix and a slice thickness of 0.

View Article and Find Full Text PDF

(1) Background: To predict clinical outcomes in patients with aneurysmal subarachnoid hemorrhage (aSAH) and delayed cerebral ischemia (DCI) by assessment of the cerebral perfusion using a 2D perfusion angiography (2DPA) time-contrast agent (CA) concentration model. (2) Methods: Digital subtraction angiography (DSA) data sets of n = 26 subjects were acquired and post-processed focusing on changes in contrast density using a time-concentration model at three time points: (i) initial presentation with SAH (T0); (ii) vasospasm-associated acute clinical impairment (T1); and (iii) directly after endovascular treatment (T2) of SAH-associated large vessel vasospasm (LVV), which resulted in n = 78 data sets. Maximum slope (MS in SI/ms), time-to-peak (TTP in ms), and maximum amplitude of a CA bolus (dSI) were measured in brain parenchyma using regions of interest (ROIs).

View Article and Find Full Text PDF

Rationale And Objectives: To evaluate clinical feasibility and image quality of a comprehensive ultrafast brain MRI protocol with multi-shot echo planar imaging and deep learning-enhanced reconstruction at 1.5T.

Materials And Methods: Thirty consecutive patients who underwent clinically indicated MRI at a 1.

View Article and Find Full Text PDF

Objectives: To assess the benefits of ultra-high-resolution CT (UHR-CT) with deep learning-based image reconstruction engine (AiCE) regarding image quality and radiation dose and intraindividually compare it to normal-resolution CT (NR-CT).

Methods: Forty consecutive patients with head and neck UHR-CT with AiCE for diagnosed head and neck malignancies and available prior NR-CT of a different scanner were retrospectively evaluated. Two readers evaluated subjective image quality using a 5-point Likert scale regarding image noise, image sharpness, artifacts, diagnostic acceptability, and assessability of various anatomic regions.

View Article and Find Full Text PDF

Rationale And Objectives: To prospectively evaluate feasibility and robustness of an accelerated T2 mapping sequence (GRAPPATINI) in brain imaging and to assess its synthetic T2-weighted images (sT2w) in comparison with a standard T2-weighted sequence (T2 TSE).

Material And Methods: Volunteers were included to evaluate the robustness and consecutive patients for morphological evaluation. They were scanned on a 3 T MR-scanner.

View Article and Find Full Text PDF

Purpose: To evaluate the effects of single-energy metal artifact reduction (SEMAR) on image quality of ultra-high-resolution CT-angiography (UHR-CTA) with intracranial implants after aneurysm treatment.

Methods: Image quality of standard and SEMAR-reconstructed UHR-CT-angiography images of 54 patients who underwent coiling or clipping was retrospectively evaluated. Image noise (i.

View Article and Find Full Text PDF

Background: Filament perforation is a widely-used method to induce subarachnoid hemorrhage (SAH) in mice. Whereas the perforation site has been assumed to be in the branching of middle cerebral artery (MCA) and anterior cerebral artery (ACA), we recently observed more proximal perforations.

Methods: Filament perforation was performed in CD1- (n = 10) and C57Bl/6N-mice (n = 9) ex vivo.

View Article and Find Full Text PDF

The field of radiomics is rapidly expanding and gaining a valuable role in neuro-oncology. The possibilities related to the use of radiomic analysis, such as distinguishing types of malignancies, predicting tumor grade, determining the presence of particular molecular markers, consistency, therapy response, and prognosis, can considerably influence decision-making in medicine in the near future. Even though the main focus of radiomic analyses has been on glial CNS tumors, studies on other intracranial tumors have shown encouraging results.

View Article and Find Full Text PDF

Catheter-based ultrasound-thrombolysis has been successfully used in a small clinical trial in order to enhance recombinant tissue plasminogen activator (rtPA)-fibrinolysis, for the treatment of spontaneous intracerebral hemorrhages (ICHs). The aim of this study was to investigate the ultra-early effects of ultrasound on hematoma and the surrounding brain tissue in a porcine ICH-model. To achieve this, 21 pigs with a right frontal ICH were randomly assigned to four groups: (1) drainage ( = 3), (2) drainage + rtPA ( = 6), (3) drainage + ultrasound ( = 6), and (4) drainage + ultrasound + rtPA ( = 6).

View Article and Find Full Text PDF

Up to 60% of atypical meningiomas (World Health Organization (WHO) grade II) reoccur within 5 years after resection. However, no clear radiological criteria exist to identify tumors with higher risk of relapse. In this study, we aimed to assess the association of certain radiomic and semantic features of atypical meningiomas in MRI with tumor recurrence.

View Article and Find Full Text PDF

The present study in rats was conducted to identify brain regions affected by the interruption of vestibular transmission and to explore selected aspects of their functional connections. We analyzed, by positron emission tomography (PET), the regional cerebral glucose metabolism (rCGM) of cortical, and subcortical cerebral regions processing vestibular signals after an experimental lesion of the left laterodorsal thalamic nucleus, a relay station for vestibular input en route to the cortical circuitry. PET scans upon galvanic vestibular stimulation (GVS) were conducted in each animal prior to lesion and at post-lesion days (PLD) 1, 3, 7, and 20, and voxel-wise statistical analysis of rCGM at each PLD compared to pre-lesion status were performed.

View Article and Find Full Text PDF

As noted in Wikipedia, refers to having 'incurred risk by being involved in achieving a goal', where ' is a synecdoche for the person involved, and is the metaphor for actions on the field of play under discussion'. For exascale applications under development in the US Department of Energy Exascale Computing Project, nothing could be more apt, with the being exascale applications and the being delivering comprehensive science-based computational applications that effectively exploit exascale high-performance computing technologies to provide breakthrough modelling and simulation and data science solutions. These solutions will yield high-confidence insights and answers to the most critical problems and challenges for the USA in scientific discovery, national security, energy assurance, economic competitiveness and advanced healthcare.

View Article and Find Full Text PDF

Longitudinal in vivo imaging studies characterizing subarachnoid hemorrhage (SAH)-induced large artery vasospasm (LAV) in mice are lacking. We developed a SAH-scoring system to assess SAH severity in mice using micro CT and longitudinally analysed LAV by intravenous digital subtraction angiography (i.v.

View Article and Find Full Text PDF

All lattice-QCD calculations of the hadronic-vacuum-polarization contribution to the muon's anomalous magnetic moment to date have been performed with degenerate up- and down-quark masses. Here we calculate directly the strong-isospin-breaking correction to a_{μ}^{HVP} for the first time with physical values of m_{u} and m_{d} and dynamical u, d, s, and c quarks, thereby removing this important source of systematic uncertainty. We obtain a relative shift to be applied to lattice-QCD results obtained with degenerate light-quark masses of δa_{μ}^{HVP,m_{u}≠m_{d}}=+1.

View Article and Find Full Text PDF

Purpose: The positron emission tomography ligand [ F]MK-9470 is an inverse agonist that binds reversibly and with high affinity to the cannabinoid type 1 receptor. Due to its slow brain kinetics, care is required in the definition of its dissociation rates from the receptor. The goal of this study was to investigate pharmacokinetic analysis methods using an arterial input function.

View Article and Find Full Text PDF

Spontaneous slow oscillation-associated slow wave activity represents an internally generated state which is characterized by alternations of network quiescence and stereotypical episodes of neuronal activity - slow wave events. However, it remains unclear which macroscopic signal is related to these active periods of the slow wave rhythm. We used optic fiber-based calcium recordings of local neural populations in cortex and thalamus to detect neurophysiologically defined slow calcium waves in isoflurane anesthetized rats.

View Article and Find Full Text PDF

Objectives: While clinically the safety and efficacy of waterjet resection of brain tumors have been shown, evidence that waterjet dissection improves tumor resection radicality in comparison with conventional techniques is still missing. In the present study, resection radicality and tumor-free long-term survival of both techniques were evaluated in a C6-glioma model.

Material And Methods: Fifty-thousand C6-glioma cells were stereotactically transplanted in the left frontal lobe of 100 male Sprague-Dawley rats.

View Article and Find Full Text PDF