Researchers and practitioners in sports nutrition would greatly benefit from a rapid, portable, and non-invasive technique to measure muscle glycogen, both in the laboratory and field. This explains the interest in MuscleSound, the first commercial system to use high-frequency ultrasound technology and image analysis from patented cloud-based software to estimate muscle glycogen content from the echogenicity of the ultrasound image. This technique is based largely on muscle water content, which is presumed to act as a proxy for glycogen.
View Article and Find Full Text PDFMed Sci Sports Exerc
January 2018
Introduction: Creatine (Cr) and carbohydrate loadings are dietary strategies used to enhance exercise capacity. This study examined the metabolic and performance effects of a combined CR and CHO loading regiment on time trial (TT) cycling bouts.
Methods: Eighteen well-trained (~65 mL·kg·min V˙O2peak) men completed three performance trials (PT) that comprised a 120-km cycling TT interspersed with alternating 1- and 4-km sprints (six sprints each) performed every 10 km followed by an inclined ride to fatigue (~90% V˙O2peak).
Unlabelled: Standardizing a dual x-ray absorptiometry (DXA) protocol is thought to provide a reliable measurement of body composition.
Purpose: We investigated the effects of manipulating muscle glycogen and creatine content independently and additively on DXA estimates of lean mass.
Method: Eighteen well-trained male cyclists undertook a parallel group application of creatine loading (n = 9) (20 g·d for 5 d loading; 3 g·d maintenance) or placebo (n = 9) with crossover application of glycogen loading (12 v 6 g·kg BM per day for 48 h) as part of a larger study involving a glycogen-depleting exercise protocol.
Purpose: Creatine uptake by muscle cells is increased in the presence of insulin. Accordingly, compounds with insulin-like actions may also augment creatine uptake. The aim of this study was to investigate whether Trigonella foenum-graecum (fenugreek), an insulin mimetic, increases total intracellular creatine levels in vitro.
View Article and Find Full Text PDFWe investigated the compartmentation of the catabolism of dodecanedioate (DODA), azelate, and glutarate in perfused rat livers, using a combination of metabolomics and mass isotopomer analyses. Livers were perfused with recirculating or nonrecirculating buffer containing one fully (13)C-labeled dicarboxylate. Information on the peroxisomal versus mitochondrial catabolism was gathered from the labeling patterns of acetyl-CoA proxies, i.
View Article and Find Full Text PDFOur previous work in perfused rat livers has demonstrated that 4-hydroxynonenal (HNE) is catabolized predominantly via β oxidation. Therefore, we hypothesized that perturbations in β oxidation, such as diet-altered fatty acid oxidation activity, could lead to changes in HNE levels. To test our hypothesis, we (i) developed a simple and sensitive GC/MS method combined with mass isotopomer analysis to measure HNE and HNE analogs, 4-oxononenal (ONE) and 1,4-dihydroxynonene (DHN), and (ii) investigated the effects of four diets (standard, low-fat, ketogenic, and high-fat mix) on HNE, ONE, and DHN concentrations in rat livers.
View Article and Find Full Text PDFCalcium levulinate (4-ketopentanoate) is used as an oral and parenteral source of calcium. We hypothesized that levulinate is converted in the liver to 4-hydroxypentanoate, a new drug of abuse, and that this conversion is accelerated by ethanol oxidation. We confirmed these hypotheses in live rats, perfused rat livers, and liver subcellular preparations.
View Article and Find Full Text PDFThe present work illustrated an accurate GC/MS measurement for the low isotopomer enrichment assay of formic acid, acetic acid, propionic aicd, butyric acid, and pentanoic acid. The pentafluorobenzyl bromide derivatives of these very short chain fatty acids have high sensitivity of isotopoic enrichment due to their low natural isotopomer distribution in negative chemical ionization mass spectrometric mode. Pentafluorobenzyl bromide derivatization reaction was optimized in terms of pH, temperature, reaction time, and the amount of pentafluorobenzyl bromide versus sample.
View Article and Find Full Text PDF