Acta Stomatol Croat
December 2018
Objectives: The aim of this study was to evaluate dimensional changes of conventional glass ionomer cements, resin-modified glass-ionomer cement, and a giomer during the setting time using digital laser interferometry. Additionally, the influence of different curing modes ("high", "soft", and "low") of a light-emitting diode (LED) curing unit on dimensional changes was evaluated.
Materials And Methods: Linear curing shrinkage of conventional glass ionomer cements (CGICs): Fuji IX Extra (F9E), Fuji IX Fast (F9F), Ketac Molar Aplicap (KM), Ketac Molar Quick Aplicap (KMQ), resin-modified glass ionomer cement (RM GIC): Fuji II LC (F2LC) and giomer: Beautifil II (B2) was analyzed.
Aim: To determine if the addition of inert fillers to a bioactive dental restorative composite material affects its degree of conversion (DC), polymerization shrinkage (PS), and microhardness (HV).
Methods: Three amorphous calcium phosphate (ACP)-based composite resins: without added fillers (0-ACP), with 10% of barium-glass fillers (Ba-ACP), and with 10% of silica fillers (Si-ACP), as well as commercial control (Ceram•X, Dentsply DeTrey) were tested in laboratory conditions. The amount of ACP (40%) and the composition of the resin mixture (based on ethoxylated bisphenol A dimethacrylate) was the same for all ACP materials.
Objectives: Composite resin materials shrink during polymerization regardless of curing unit or polymerization program used. However, different polymerization programs lead to different shrinkage percentages. The aim of this study was to evaluate linear polymerization shrinkage for five composite materials polymerized with curing modes of two LED curing units.
View Article and Find Full Text PDFAcceptable signal recovery of the band-pass signals typically used in the off-axis digital holography systems is possible in the undersampling conditions. A typical system is considered in which the angle between two beams represents a variable parameter. For the given signal bandwidth and experimental conditions the hologram reconstruction is constrained by the sampling frequency of the array photo-detector.
View Article and Find Full Text PDFThis study determined whether it was possible to detect deformations and fractures in dental hard tissues or in composite material from internal stresses using double-exposure holographic interferometry. On the proximal side of eight intact human permanent premolars, a direct Class II cavity was prepared and restored with a self-etching adhesive (Clearfil SE Bond) and Tetric Ceram, a resin composite. In five of the specimens, Tetric Flow was used as an elastic layer.
View Article and Find Full Text PDF