Aim: To describe the clinical nurse specialist role and its outcomes and challenges.
Design: Participatory Action Research conducted in Finland between the fall of 2017 and the end of 2018.
Methods: A core participatory action research team (n = 10) led the design, implementation and evaluation of the research.
In interior cardiac computed tomography (CT) imaging, the x-ray beam is collimated to a limited field-of-view covering the heart volume, which decreases the radiation exposure to surrounding tissues. Spectral CT enables the creation of virtual monochromatic images (VMIs) through a computational material decomposition process. This study investigates the utility of VMIs for beam hardening (BH) reduction in interior cardiac CT, and further, the suitability of VMIs for coronary artery calcium (CAC) scoring and volume assessment is studied using spectral photon counting detector CT (PCD-CT).
View Article and Find Full Text PDFComputed tomography (CT) is the reference method for cardiac imaging, but concerns have been raised regarding the radiation dose of CT examinations. Recently, photon counting detectors (PCDs) and interior tomography, in which the radiation beam is limited to the organ-of-interest, have been suggested for patient dose reduction. In this study, we investigated interior PCD-CT (iPCD-CT) for non-enhanced quantification of coronary artery calcium (CAC) using an anthropomorphic torso phantom and ex vivo coronary artery samples.
View Article and Find Full Text PDFAim: To develop, implement and evaluate the clinical nurse specialist's role within a specialist medical healthcare hospital. A secondary aim was to assess the feasibility of the 'Clinical Nurse Specialist Conceptualisation, Implementation, and Evaluation framework' in the role implementation.
Background: Implementation of advanced practice nursing roles is an increasing practice around the globe; however, the implementation of these roles is multidimensional, complex process.
We evaluated the physical stability of thin polymethacrylate-drug films under three different storage conditions by X-ray powder diffraction, differential scanning calorimetry, scanning electron microscopy, polarized light microscopy, and Fourier transform infrared spectroscopy. Mechanical properties i.e.
View Article and Find Full Text PDFPharmaceutical thin films are versatile drug-delivery platforms i.e. allowing transdermal, oral, sublingual and buccal administration.
View Article and Find Full Text PDFThe aim of the present study is to monitor the release of perphenazine (PPZ) from thin polymer films in real-time by the multi-parametric surface plasmon resonance method (MP-SPR). The MP-SPR method is capable of measuring changes in polymer films that are significantly thicker than the apparent scanning depth of the SPR field. The in vitro reference measurements confirm that the MP-SPR results can be correlated to the in vitro release of PPZ.
View Article and Find Full Text PDF