Background: Point-of-care testing provides a representation of the patient's coagulability status during effective postpartum hemorrhage management. Baseline values of rotational thromboelastometry (ROTEM) have not yet been reported in a heterogeneous obstetric population. This study aimed to establish a baseline for a diverse population representative of the United States.
View Article and Find Full Text PDF: Not all labor and delivery floors are equipped with ultrasound machines which can serve the needs of both obstetricians and anesthesiologists. This cross-sectional, blinded, randomized observational study compares the image resolution (RES), detail (DET), and quality (IQ) acquired by a handheld ultrasound, the Butterfly iQ, and a mid-range mobile device, the Sonosite M-turbo US (SU), to evaluate their use as a shared resource. : Seventy-four pairs of ultrasound images were obtained for different imaging purposes: 29 for spine (Sp), 15 for transversus abdominis plane (TAP) and 30 for diagnostic obstetrics (OB) purposes.
View Article and Find Full Text PDFWe present a case of a pregnant patient with an unrepaired vein of Galen malformation (VGAM) and left ventricular (LV) dilation. Patients with VGAM lesions typically present during childhood with cardiac failure or developmental delay prompting embolization. Therefore, it is highly unusual for an adult to present with an unrepaired lesion.
View Article and Find Full Text PDFRotational Thromboelastometry (ROTEM) Delta has been described in several postpartum hemorrhage algorithms, but this device requires pipetting and careful mixing of reagents to initiate the clotting reaction. In contrast, thromboelastography (TEG 6s) and the Quantra devices operate utilizing an automated pre-mixed cartridge that only requires a blood sample to start the clot strength analysis. We compared the correlation between 3 point of care viscoelastic testing (POCVT) devices to laboratory Clauss fibrinogen and platelets, their inter-device correlation, and the total running time difference between Quantra and ROTEM.
View Article and Find Full Text PDFOver the past 30 years, maternal mortality has increased in the United States to 18 deaths per 100,000 live births. Obstetric emergencies, including hemorrhage, hypertensive disorders in pregnancy, HELLP syndrome, and amniotic fluid embolism, and anesthesia complications, including high neuraxial blockade, local anesthetic systemic toxicity, and the difficult obstetric airway, contribute to maternal cardiac arrest and maternal and fetal morbidity and mortality. Expeditious intervention by the obstetric anesthesiologist is critical in these emergent scenarios, and knowledge of best practices is essential to improve maternal and fetal outcomes.
View Article and Find Full Text PDFObjectives: Aberrant automated blood pressure (BP) readings during caesarean delivery may lead to disruptions in monitoring. The present study compared the frequency of aberrant BP readings across two types of commercially available BP monitoring systems in use during caesarean delivery.
Methods: This was a retrospective observational study using two comparable patient cohorts that resulted from simultaneous introduction of two types of monitors into a single obstetric surgical center in which similar patients were treated for the same surgical procedure by the same set of clinicians during the same year.
Study Objective: Our study sought to determine whether or not nitrous oxide analgesia decreases pain compared to oxygen placebo during external cephalic version for breech presentation. Procedural success may be limited by pain and anxiety. Although neuraxial anesthesia has been studied extensively for these procedures, many centers lack resources for routine use.
View Article and Find Full Text PDFBACKGROUNDThe effects of the novel coronavirus disease 2019 (COVID-19) in pregnancy remain relatively unknown. We present a case of second trimester pregnancy with symptomatic COVID-19 complicated by severe preeclampsia and placental abruption.METHODSWe analyzed the placenta for the presence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) through molecular and immunohistochemical assays and by and electron microscopy and measured the maternal antibody response in the blood to this infection.
View Article and Find Full Text PDFA 35-year-old parturient with antiphospholipid syndrome and a working diagnosis of hemolysis, elevated liver enzyme, and low platelets (HELLP) underwent a cesarean delivery 9 hours after receiving heparin. Her preoperative activated partial thromboplastin time and rotational thromboelastometry (ROTEM) intrinsic pathway (INTEM) clotting time were 120 and 1870 seconds, respectively. Fresh frozen plasma was administered for heparin neutralization.
View Article and Find Full Text PDFOver the past 30 years, maternal mortality has increased in the United States to 18 deaths per 100,000 live births. Obstetric emergencies, including hemorrhage, hypertensive disorders in pregnancy, HELLP syndrome, and amniotic fluid embolism, and anesthesia complications, including high neuraxial blockade, local anesthetic systemic toxicity, and the difficult obstetric airway, contribute to maternal cardiac arrest and maternal and fetal morbidity and mortality. Expeditious intervention by the obstetric anesthesiologist is critical in these emergent scenarios, and knowledge of best practices is essential to improve maternal and fetal outcomes.
View Article and Find Full Text PDF