Osseointegration is a crucial property of biomaterials used for bone defect repair. While titanium is the gold standard in craniofacial surgeries, various polymeric biomaterials are being explored as alternatives. However, polymeric materials can be bioinert, hindering integration with surrounding tissues.
View Article and Find Full Text PDFThe present work describes a preclinical trial (, and ) protocol to assess the biomechanical performance and osteogenic capability of 3D-printed polymeric scaffolds implants used to repair partial defects in a sheep mandible. The protocol spans multiple steps of the medical device development pipeline, including initial concept design of the scaffold implant, digital twin finite element modeling, manufacturing of the device prototype, device implantation, and laboratory mechanical testing. First, a patient-specific one-body scaffold implant used for reconstructing a critical-sized defect along the lower border of the sheep mandible ramus was designed using on computed-tomographic (CT) imagery and computer-aided design software.
View Article and Find Full Text PDFAutologous bone replacement remains the preferred treatment for segmental defects of the mandible; however, it cannot replicate complex facial geometry and causes donor site morbidity. Bone tissue engineering has the potential to overcome these limitations. Various commercially available calcium phosphate-based bone substitutes (Novabone, BioOss, and Zengro) are commonly used in dentistry for small bone defects around teeth and implants.
View Article and Find Full Text PDFThe aim of the present study was to develop measurement methods to evaluate occlusal differences in digitally-articulated and hand-articulated models in final occlusal planning for orthognathic surgery. A total of 10 (five class II and five class III) previously treated orthognathic cases were analysed by three oral and maxillofacial surgeon investigators, creating a total of thirty cases. Investigators used physical models to create a preferred hand-held final occlusion, which were then scanned and saved utilising a Trios 3® scanner (3Shape).
View Article and Find Full Text PDFThe workflow for a prefabricated prelaminated fibula free flap has been almost entirely digitized. One of the last 2 remaining steps is the impression making in stage 1 surgery. This article describes a novel computed-tomography based digital scanning technique with an assessment of the resultant accuracy.
View Article and Find Full Text PDFPurpose: Sight-threatening injuries associated with orbital fractures are of major concern to maxillofacial surgeons whom are often the first asked to assess these patients. Eliciting signs and symptoms that are predictive of these injuries would allow expedited ophthalmic consultation and appropriate management. We hypothesized that abnormal pupillary response is predictive of major ocular injuries.
View Article and Find Full Text PDFJ Oral Maxillofac Surg
July 2011
Dry socket, or alveolar osteitis, can occur because of the removal of teeth. No clear etiology has been acknowledged; however, numerous risk factors have been proposed and tested. We report on the results of a prospective, multicenter study of the incidence and factors affecting the occurrence of alveolar osteitis at the Royal Dental Hospital of Melbourne and Community Dental Clinics in Melbourne, Australia.
View Article and Find Full Text PDF