Publications by authors named "Krasa J"

Most studies that address the relationship between socio-economic characteristics and soil erosion focus on the effects of soil erosion on socio-economic conditions at different levels, from global to smallholder. Few, if any, efforts are made to address the influence of socio-economic variables on the soil erosion rate as an indicator of landscape degradation. The present study was carried out using spatial data from 402 catchments that cover Poland, to find out how socio-economic variables, which include area-weighted average income per capita (PLN km), area-weighted average gross domestic product (PLN km), population density (person km), and human development index can drive the soil erosion rate (kg ha yr), along with annual precipitation, soil and geomorphological variables that include soil organic carbon content, soil water content, clay ratio, stream gradient, and terrain slope.

View Article and Find Full Text PDF

This paper describes design, development, and implementation of a multi-channel magnetic electron spectrometer for the application in laser-plasma interaction experiments carried out at the Prague Asterix Laser System. Modular design of the spectrometer allows the setup in variable configurations to evaluate the angular distribution of hot electron emission. The angular array configuration of the electron spectrometers consists of 16 channels mounted around the target.

View Article and Find Full Text PDF

When high-energy and high-power lasers interact with matter, a significant part of the incoming laser energy is transformed into transient electromagnetic pulses (EMPs) in the range of radiofrequencies and microwaves. These fields can reach high intensities and can potentially represent a significative danger for the electronic devices placed near the interaction point. Thus, the comprehension of the origin of these electromagnetic fields and of their distribution is of primary importance for the safe operation of high-power and high-energy laser facilities, but also for the possible use of these high fields in several promising applications.

View Article and Find Full Text PDF

The nuclear reaction known as proton-boron fusion has been triggered by a subnanosecond laser system focused onto a thick boron nitride target at modest laser intensity (∼10^{16}W/cm^{2}), resulting in a record yield of generated α particles. The estimated value of α particles emitted per laser pulse is around 10^{11}, thus orders of magnitude higher than any other experimental result previously reported. The accelerated α-particle stream shows unique features in terms of kinetic energy (up to 10 MeV), pulse duration (∼10 ns), and peak current (∼2 A) at 1 m from the source, promising potential applications of such neutronless nuclear fusion reactions.

View Article and Find Full Text PDF

Spatially distributed modelling of sediment and phosphorus fluxes on a scale of thousands of square kilometers always involves a compromise between the quality of the data input and the complexity of the model that can be applied. WaTEM/SEDEM offers an approach that allows us to target on spatially focused outputs that can easily be implemented in the decision-making process for effective watershed control. The results for a study area covering the watersheds of 58 large reservoirs threatened by eutrophication within the Czech Republic are presented here as an example of the available analyses.

View Article and Find Full Text PDF

Intense rainfall-runoff events and subsequent soil erosion can cause serious damage to the infrastructure in residential areas in Europe countries and all over the world. In the Czech Republic, the Ministry of the Interior has supported an analysis dealing with the risks to residents, infrastructure, and water bodies from flash floods and sediment transport. A total of more than 150,000 risk points were identified by GIS morphology and land-use analysis.

View Article and Find Full Text PDF

Optical generation of compact magnetized plasma structures is studied in the moderate intensity domain. A sub-ns laser beam irradiated snail-shaped targets with the intensity of about 10 W/cm. With a neat optical diagnostics, a sub-megagauss magnetized plasmoid is traced inside the target.

View Article and Find Full Text PDF

This paper presents a newly-derived method for directly determining the amount of transported dissolved phosphorus by water erosion. The results of the method are compared to prediction based on enrichment ratio (as proposed by Sharpley) and average share of dissolved phosphorus (DP) in total transported phosphorus (5%) that is widely used in the Czech Republic. Four study areas (catchments of dozens of sq.

View Article and Find Full Text PDF

Measurements of the return-current flowing through a solid target irradiated with the sub-nanosecond kJ-class Prague Asterix Laser System is reported. A new inductive target probe was developed which allows us measuring the target current derivative in a kA/ns range. The dependences of the target current on the laser pulse energy for cooper, graphite, and polyethylene targets are reported.

View Article and Find Full Text PDF

State-of-the-art laser systems are able to generate ionising radiation of significantly high energies by focusing ultra-short and intense pulses onto targets. Thus, measures ensuring the radiation protection of both working personnel and the general public are required. However, commercially available dosemeters are primarily designed for measurement in continuous fields.

View Article and Find Full Text PDF

A new type of Faraday cup, capable of detecting high energy charged particles produced in a high intensity laser-matter interaction environment, has recently been developed and demonstrated as a real-time detector based on the time-of-flight technique. An array of these Faraday cups was designed and constructed to cover different observation angles with respect to the target normal direction. Thus, it allows reconstruction of the spatial distribution of ion current density in the subcritical plasma region and the ability to visualise its time evolution through time-of-flight measurements, which cannot be achieved with standard laser optical interferometry.

View Article and Find Full Text PDF

In this work, the characteristics of laser plasma produced by ablation of pure and doped targets are studied. An excimer KrF laser was used to induce ablation. Pure Cu, Cu with 2% of Be, and Cu with 4% of Sn targets were ablated to evaluate the influence of these admixture on the emission of Cu ions.

View Article and Find Full Text PDF

The iodine laser at PALS Laboratory in Prague, operating at 1315 nm fundamental harmonics and at 300 ps FWHM pulse length, is employed to irradiate thin hydrogenated targets placed in vacuum at intensities on the order of 10(16) W∕cm(2). The laser-generated plasma is investigated in terms of proton and ion emission in the forward and backward directions. The time-of-flight technique, using ion collectors and semiconductor detectors, is used to measure the ion currents and the corresponding velocities and energies.

View Article and Find Full Text PDF

An overview of the last experimental campaigns on laser-driven ion acceleration performed at the PALS facility in Prague is given. Both the 2 TW, sub-nanosecond iodine laser system and the 20 TW, femtosecond Ti:sapphire laser, recently installed at PALS, are used along our experiments performed in the intensity range 10(16)-10(19) W∕cm(2). The main goal of our studies was to generate high energy, high current ion streams at relatively low laser intensities.

View Article and Find Full Text PDF

The generation of fast highly charged metal ions with the use of the sub-nanosecond Prague Asterix Laser System, operated at a fundamental wavelength of 1315 nm, is reported. Particular attention is paid to shot-to-shot reproducibility in the ion emission. Au and Pd targets were exposed to intensities up to 5 × 10(16) W∕cm(2).

View Article and Find Full Text PDF

A 10(16) W∕cm(2) Asterix laser pulse intensity, 1315 nm at the fundamental frequency, 300 ps pulse duration, was employed at PALS laboratory of Prague, to irradiate thick and thin primary CD(2) targets placed inside a high vacuum chamber. The laser irradiation produces non-equilibrium plasma with deutons and carbon ions emission with energy of up to about 4 MeV per charge state, as measured by time-of-flight (TOF) techniques by using ion collectors and silicon carbide detectors. Accelerated deutons may induce high D-D cross section for fusion processes generating 3 MeV protons and 2.

View Article and Find Full Text PDF

The spectra of neutrons outside the plasma focus device PF-1000 with an upper energy limit of ≈1 MJ was measured using a Bonner spheres spectrometer in which the active detector of thermal neutrons was replaced by nine thermoluminescent chips. As an a priori spectrum for the unfolding procedure, the spectrum calculated by means of the Monte Carlo method with a simplified model of the discharge chamber was selected. Differences between unfolded and calculated spectra are discussed with respect to properties of the discharge vessel and the laboratory layout.

View Article and Find Full Text PDF

Ultrafast plasma light ion streams have been produced using the 300 ps, kJ-class iodine laser, operating at PALS Centre in Prague. Ion detection was performed through standard ion collectors (IC) in time-of-flight configuration (TOF), shielded by thin metallic absorbers. This new diagnostics technique has been theoretically studied and experimentally tested in order to cut the long photopeak contribution and to analyze the ultrafast particle signal.

View Article and Find Full Text PDF

Emission of carbon currents reaching values up to 2 A/cm(2) at a distance of 1 m from the laser ion source driven by the subnanosecond Prague Asterix Laser System operated at a fundamental wavelength of 1315 nm is reported. Graphite targets were exposed to intensities up to 5x10(16) W/cm(2) varying both the laser energy and the position of the laser beam focus with respect to the target surface. The maximum energy gain of carbon ions was approximately = 1 MeV/u.

View Article and Find Full Text PDF

Results of recent studies on highly charged Au ion generation, using the intense long pulses of the PALS high power iodine laser (lambda=1.315 microm, E(L)=800 J400 ps), operating under variable experimental conditions (1omega, 3omega, varying target thickness and changing focus positions), are presented. Both the ion collectors and the ion electrostatic analyzers were applied for the identification of ions in a large distance from the target.

View Article and Find Full Text PDF

A large-scale, double-stream gas puff target has been illuminated by sub-kJ, near-infrared (NIR) focused laser pulses at the PALS facility (Prague Asterix Laser System) to produce high-energy pulses of soft X rays from hot, dense plasma. The double-puff arrangement ensures high gas density and conversion efficiency from NIR to X rays approaching that typical for solid targets. In addition, its major advantage over solid targets is that it is free of debris and has substantially suppressed charged-particle emission.

View Article and Find Full Text PDF

A linear accelerator based source of coherent radiation, FLASH (Free-electron LASer in Hamburg) provides ultra-intense femtosecond radiation pulses at wavelengths from the extreme ultraviolet (XUV; lambda<100nm) to the soft X-ray (SXR; lambda<30nm) spectral regions. 25-fs pulses of 32-nm FLASH radiation were used to determine the ablation parameters of PMMA - poly (methyl methacrylate). Under these irradiation conditions the attenuation length and ablation threshold were found to be (56.

View Article and Find Full Text PDF

A multichannel detection system having a dynamic range of approximately 1 x 10(-9) Gy --20 Gy was developed with the use of commercially produced Si-photodiodes and TLDs for accurate measurement of X ray energy emitted from plasma-focus facility and from laser-produced plasmas. The proof of linearity of the employed detectors accomplished by a comparison of their responses to a broad band spectrum of X rays emitted from plasmas, is reported. It is demonstrated that TLDs irradiated with no protective filter show an incorrect response due to overloading in the sub-keV range and repopulation of dosimetric peaks induced by the UV radiation.

View Article and Find Full Text PDF