Background: The monocyte-to-lymphocyte ratio (MLR), a systemic inflammation biomarker, has been shown to predict patient outcomes in several types of cancer. This study aimed to determine the association between MLR and local control (LC) and cause-specific survival (CSS) rates in patients with non-small cell lung cancer (NSCLC) treated with stereotactic body radiation therapy (SBRT).
Materials And Methods: The median age of the 194 included participants (144 men, 50 women) was 80 (range, 50-96) years.
Introduction: Whereas repetitive facilitative exercise (RFE) affects primarily recovery of motor impairment after stroke, task-oriented training (TOT) focuses on facilitating daily use of the affected upper extremity. However, feasibility of combined RFE and TOT has not been reported. We originated "task-oriented RFE," as a new combination therapy for patients with hemiplegic upper extremity after subacute stroke, to examine its feasibility in convalescent rehabilitation wards.
View Article and Find Full Text PDF. For response-adapted adaptive radiotherapy (R-ART), promising biomarkers are needed to predict post-radiotherapy (post-RT) responses using routine clinical information obtained during RT. In this study, a patient-specific biomechanical model (BM) of the head and neck squamous cell carcinoma (HNSCC) was proposed using the pre-RT maximum standardized uptake value (SUV) ofF-fluorodeoxyglucose (FDG) and tumor structural changes during RT as evaluated using computed tomography (CT).
View Article and Find Full Text PDFRadiotherapy with deep inspiration breath hold (DIBH) reduces doses to the lungs and organs at risk. The stability of breath holding and reproducibility of tumor location are higher during expiration than during inspiration; therefore, we developed an irradiation method combining DIBH and real-time tumor-tracking radiotherapy (RTRT) (DBRT). Nine patients were enrolled in this study.
View Article and Find Full Text PDFPurpose: This study evaluated the intra- and inter-fractional variation of tumors with fiducial markers (FMs), relative to the tumor-FM distance, to establish how close an FM should be inserted for respiratory-gated stereotactic body radiation therapy (RG-SBRT).
Methods: Forty-five lung tumors treated with RG-SBRT were enrolled. End-expiratory computed tomography (CT) (CT) and four-dimensional-CT (4D-CT) scans were obtained for planning.
Unlike drug selection, radiation parameters (field, dose) are not based on driver gene mutations in patients with metastatic non-small cell lung cancer (NSCLC). This study aimed to compare radiosensitivity in NSCLC with and without EGFR driver gene mutations using clinical and in vitro data. The clinical study included 42 patients who underwent whole-brain radiotherapy for brain metastases from NSCLC; of these, 13 patients had EGFR mutation-positive tumors.
View Article and Find Full Text PDFObjective: The objectives of this study are: (1) to develop a convolutional neural network model that yields pseudo high-energy CT (CT) from simple image processed low-energy CT (CT) images, and (2) to create a pseudo iodine map (IM) and pseudo virtual non-contrast (VNC) images for thoracic and abdominal regions.
Methods: Eighty patients who underwent dual-energy CT (DECT) examinations were enrolled. The data obtained from 55, 5, and 20 patients were used for training, validation, and testing, respectively.
This exploratory and retrospective study aimed to evaluate whether there is a difference in the overall survival (OS) rates of patients with stage IV lung cancer who underwent radiation therapy (RT) depending on the presence or absence of immune checkpoint inhibitors (ICIs) and the timing of their use. Eighty patients with histologically confirmed stage IV lung cancer were enrolled, and ICIs were administered to thirty (37.5%).
View Article and Find Full Text PDFObjective: This study aims to retrospectively compare the stress map of the lung with pulmonary function test (PFT) results in lung cancer patients and to evaluate the potential of the stress map as an imaging biomarker for chronic obstructive pulmonary disease (COPD).
Methods: 25 lung cancer patients with pre-treatment four-dimensional CT (4DCT) and PFT data were retrospectively analysed. PFT metrics were used to diagnose obstructive lung disease.
Purpose: We investigated optimal peritumoral size and constructed predictive models for epidermal growth factor receptor (EGFR) mutation.
Methods: A total of 164 patients with lung adenocarcinoma were retrospectively analyzed. Radiomic signatures for the intratumoral region and combinations of intratumoral and peritumoral regions (3, 5, and 7 mm) from computed tomography images were extracted using analysis of variance and least absolute shrinkage.
The purpose of this study is to develop the predictive models for epidermal growth factor receptor (EGFR) mutation status and subtypes [exon 21-point mutation (L858R) and exon 19 deletion mutation (19Del)] and evaluate their clinical usefulness. Total 172 patients with lung adenocarcinoma were retrospectively analyzed. The analysis of variance and the least absolute shrinkage were used for feature selection from plain computed tomography images.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
January 2023
. This study aimed to produce a three-dimensional liver elasticity map using the finite element method (FEM) and respiration-induced motion captured by T1-weighted magnetic resonance images (FEM-E-map) and to evaluate whether FEM-E-maps can be an imaging biomarker comparable to magnetic resonance elastography (MRE) for assessing the distribution and severity of liver fibrosis..
View Article and Find Full Text PDFIn this study, we investigated the possibility of predicting expression levels of programmed death-ligand 1 (PD-L1) using radiomic features of intratumoral and peritumoral tumors on computed tomography (CT) images. We retrospectively analyzed 161 patients with non-small cell lung cancer. We extracted radiomic features for intratumoral and peritumoral regions on CT images.
View Article and Find Full Text PDFPurpose: Anemia has been associated with poor prognosis in patients with cancer across several cancer types. It has been identified as a prognostic factor in patients with non-small cell lung cancer (NSCLC) who have undergone surgery or chemoradiotherapy. However, there are only a few reports that have evaluated the prognostic significance of anemia in patients with NSCLC undergoing stereotactic body radiation therapy (SBRT).
View Article and Find Full Text PDFPurpose: Current radiotherapy planning procedures are generally designed based on anatomical information only and use computed tomography (CT) images that do not incorporate organ-functional information. In this study, we developed a method for estimating liver elasticity using the finite element method (FEM) and four-dimensional CT (4DCT) images acquired during radiotherapy planning, and we subsequently evaluated its feasibility as a biomarker for liver fibrosis.
Materials And Methods: Twenty patients who underwent 4DCT and ultrasound-based transient elastography (UTE) were enrolled.
Purpose: This study aimed to develop a six degrees-of-freedom (6DoF) robotic moving phantom for evaluating the dosimetric impact of intrafraction rotation during respiratory-gated radiotherapy with real-time tumor monitoring in the lung.
Materials And Methods: Fifteen patients who had undergone respiratory-gated stereotactic body radiotherapy (SBRT) with the SyncTraX system for lung tumors were enrolled in this study. A water-equivalent phantom (WEP) was set at the tip of the robotic arm.
In this study, we assess a developed novel dynamic moving phantom system that can reproduce patient three-dimensional (3D) tumor motion and patient anatomy, and perform patient-specific quality assurance (QA) of respiratory-gated radiotherapy using SyncTraX. Three patients with lung cancer were enrolled in a study. 3D printing technology was adopted to obtain individualized lung phantoms using CT images.
View Article and Find Full Text PDFThis study was conducted to estimate the organ equivalent dose and effective imaging dose for four-dimensional cone-beam computed tomography (4D-CBCT) using a Monte Carlo simulation, and to evaluate the excess absolute risk (EAR) of secondary cancer incidence. The EGSnrc/BEAMnrc were used to simulate the on-board imager (OBI) from the TrueBeam linear accelerator. Specifically, the OBI was modeled based on the percent depth dose and the off-center ratio was measured using a three-dimensional (3D) water phantom.
View Article and Find Full Text PDFPurpose: This study aimed to quantify the respiration-induced motion in each pancreatic region during motion mitigation strategies and to characterize the correlations between this motion and that of the surrogate signals in cine-magnetic resonance imaging (MRI). We also aimed to evaluate the effects of these motion mitigation strategies in each pancreatic region.
Methods: Sagittal and coronal two-dimensional cine-MR images were obtained in 11 healthy volunteers, eight of whom also underwent imaging with abdominal compression (AC).
Nihon Hoshasen Gijutsu Gakkai Zasshi
March 2019
Purpose: To quantify the patient-specific imaging dose for real-time tumour monitoring in the lung during respiratory-gated stereotactic body radiotherapy (SBRT) in clinical cases using SyncTraX.
Methods And Materials: Ten patients who underwent respiratory-gated SBRT with SyncTraX were enrolled in this study. The imaging procedure for real-time tumour monitoring using SyncTraX was simulated using Monte Carlo.
Purpose: A commercially available bolus ("commercial-bolus") does not make complete contact with the irregularly shaped patient skin. This study aims to customise a patient-specific three-dimensional (3D) bolus using a 3D printing technique ("3D-bolus") and to evaluate its clinical feasibility for photon radiotherapy.
Methods: The 3D-bolus was designed using a treatment planning system (TPS) in Digital Imaging and Communications in Medicine-Radiotherapy (DICOM-RT) format, and converted to stereolithographic format for printing.
A combined system comprising the TrueBeam linear accelerator and a new real-time tumour-tracking radiotherapy system, SyncTraX, was installed at our institution. The objectives of this study are to develop a method for the verification of respiratory-gated radiotherapy with SyncTraX using cine electronic portal image device (EPID) images and a log file and to verify this treatment in clinical cases. Respiratory-gated radiotherapy was performed using TrueBeam and the SyncTraX system.
View Article and Find Full Text PDF