Understanding the neural system in the brain requires the detection of signals from the tissue. Microscale electrodes enable high spatiotemporal neural recording, whereas traditional microelectrodes cause material and geometry mismatches between the electrode and the tissue, leading to injury and signal loss during recording. In this study, we propose a fabrication technique that uses magnetic force to facilitate assembly of vertical microscale wire-electrodes on a flexible substrate.
View Article and Find Full Text PDFIn neurophysiology, achieving precise correlation between physiological responses and anatomic structures is a significant challenge. Therefore, the accuracy of the electrode marking method is crucial. In this study, we describe a tungsten-deposition method, in which tungsten oxide is generated by applying biphasic current pulses to conventional tungsten electrodes.
View Article and Find Full Text PDFDiabetes is known to cause a variety of complications, having a high correlation with Alzheimer's disease. Electrophysiological recording using a microscale needle electrode is a promising technology for the study, however, diabetic brain tissue is more difficult to record neuronal activities than normal tissue due to these complications including the development of cerebrovascular disease. Here we show an electrophysiological methodology for diabetic db/db mice (+Lepr/+Lepr) using a 4-μm-tip diameter needle-electrode device.
View Article and Find Full Text PDFMicroscale needle-like electrode technologies offer extracellular recording with a high spatiotemporal resolution. Further miniaturization of needles to nanoscale minimizes tissue injuries; however, a reduced electrode area increases electrical impedance that degrades the quality of neuronal signal recording. We overcome this limitation by fabricating a 300 nm tip diameter and 200 μm long needle electrode where the amplitude gain with a high-impedance electrode (>15 MΩ, 1 kHz) was improved from 0.
View Article and Find Full Text PDFSpecular reflections and refractive distortions are complex image properties of solid transparent objects, but despite this complexity, we readily perceive the 3D shapes of these objects (e.g., glass and clear plastic).
View Article and Find Full Text PDFChromatic induction is a major contextual effect of color appearance. Patterned backgrounds are known to induce strong chromatic induction effects. However, it has not been clarified whether the spatial extent of the chromatic surrounding induces a chromatic contrast or assimilation effects.
View Article and Find Full Text PDFMicroelectrode technology is essential in electrophysiology and has made contributions to neuroscience as well as to medical applications. However, it is necessary to minimize tissue damage associated with needle-like electrode on the brain tissue and the implantation surgery, which makes stable chronic recording impossible. Here, we report on an approach for using a 5 μm-diameter needle electrode, which enables the following of tissue motions, a surgical method.
View Article and Find Full Text PDFMicroscale needle-electrode devices offer neuronal signal recording capability in brain tissue; however, using needles of smaller geometry to minimize tissue damage causes degradation of electrical properties, including high electrical impedance and low signal-to-noise ratio (SNR) recording. We overcome these limitations using a device assembly technique that uses a single needle-topped amplifier package, called STACK, within a device of ∼1 × 1 mm Based on silicon (Si) growth technology, a <3-µm-tip-diameter, 400-µm-length needle electrode was fabricated on a Si block as the module. The high electrical impedance characteristics of the needle electrode were improved by stacking it on the other module of the amplifier.
View Article and Find Full Text PDFPerceiving the shape of three-dimensional objects is essential for interacting with them in daily life. If objects are constructed from different materials, can the human visual system accurately estimate their three-dimensional shape? We varied the thickness, motion, opacity, and specularity of globally convex objects rendered in a photorealistic environment. These objects were presented under either dynamic or static viewing condition.
View Article and Find Full Text PDFSimultaneous color contrast and assimilation are mutually opposing effects on color appearance, and their magnitude depends on spatial context. The Monnier-Shevell illusion induces a large color shift by a synergy of simultaneous assimilation and contrast using the alternating color of proximal and distant surrounds. The illusion induces a prominent effect along the blue-yellow color axis, but a subtle effect along the orthogonal color axis.
View Article and Find Full Text PDFElectronic devices used to record biological signals are important in neuroscience, brain-machine interfaces, and medical applications. Placing electronic devices below the skin surface and recording the muscle offers accurate and robust electromyography (EMG) recordings. The device stretchability and flexibility must be similar to the tissues to achieve an intimate integration of the electronic device with the biological tissues.
View Article and Find Full Text PDFProtanomalous females with X chromosome-linked color vision deficiency exhibit mild abnormalities, whereas dichromats show a distinct deficiency in discriminating certain color pairs. Dichromats have an advantage in detecting a textured target when it is camouflaged by red-green colors, owing to their insensitivity to these colors. However, it is not certain whether protanomalous females possess a similar advantage in breaking camouflage.
View Article and Find Full Text PDFMicroelectrode devices, which enable the detection of neuronal signals in brain tissues, have made significant contributions in the field of neuroscience and the brain-machine interfaces. To further develop such microelectrode devices, the following requirements must be met: i) a fine needle's diameter (<30 µm) to reduce damage to tissues; ii) a long needle (e.g.
View Article and Find Full Text PDFBundled fiber optics allow in vivo imaging at deep sites in a body. The intrinsic optical contrast detects detailed structures in blood vessels and organs. We developed a bundled-fiber-coupled endomicroscope, enabling stereoscopic three-dimensional (3-D) reflectance imaging with a multipositional illumination scheme.
View Article and Find Full Text PDFAn ultrastretchable film device is developed that can follow the shape of spherical and large deformable biological samples such as heart and brain tissues. Although the film is composed of biocompatible parylene for the device substrate and metal layers of platinum (Pt)/titanium (Ti), which are unstretchable materials, the film shows a high stretchability by patterning slits as a "Kirigami" design. A Pt/Ti-microelectrode array embedded in 11 µm thick parylene film with 5 × 91 slits exhibits a film strain of ≈250% at 9 mN strain-force (0.
View Article and Find Full Text PDFThe capacity for flexible sensory-action association in animals has been related to context-dependent attractor dynamics outside the sensory cortices. Here, we report a line of evidence that flexibly modulated attractor dynamics during task switching are already present in the higher visual cortex in macaque monkeys. With a nonlinear decoding approach, we can extract the particular aspect of the neural population response that reflects the task-induced emergence of bistable attractor dynamics in a neural population, which could be obscured by standard unsupervised dimensionality reductions such as PCA.
View Article and Find Full Text PDFBioluminescence imaging (BLI) is used in biomedical research to monitor biological processes within living organisms. Recently, fiber bundles with high transmittance and density have been developed to detect low light with high resolution. Therefore, we have developed a bundled-fiber-coupled microscope with a highly sensitive cooled-CCD camera that enables the BLI of organs within the mouse body.
View Article and Find Full Text PDFUnlabelled: The architectonic subdivisions of the brain are believed to be functional modules, each processing parts of global functions. Previously, we showed that neurons in different regions operate in different firing regimes in monkeys. It is possible that firing regimes reflect differences in underlying information processing, and consequently the firing regimes in homologous regions across animal species might be similar.
View Article and Find Full Text PDFCategorical perception is a ubiquitous function in sensory information processing, and is reported to have important influences on the recognition of presented and/or memorized stimuli. However, such complex interactions among categorical perception and other aspects of sensory processing have not been explained well in a unified manner. Here, we propose a recurrent neural network model to process categorical information of stimuli, which approximately realizes a hierarchical Bayesian estimation on stimuli.
View Article and Find Full Text PDFThe glare illusion refers to brightness enhancement and the perception of a self-luminous appearance that occurs when a central region is surrounded by a luminance gradient. The center region appears to be a light source, with its light dispersing into the surrounding region. If the luminous edge is critical for generating the illusion, modulating the perceived luminance of the image, and switching its appearance from luminous to nonluminous, would have a strong impact on lightness and brightness estimation.
View Article and Find Full Text PDFHumans can visually recognize material categories of objects, such as glass, stone, and plastic, easily. However, little is known about the kinds of surface quality features that contribute to such material class recognition. In this paper, we examine the relationship between perceptual surface features and material category discrimination performance for pictures of materials, focusing on temporal aspects, including reaction time and effects of stimulus duration.
View Article and Find Full Text PDFWell-trained experts in pearl grading have been thought to evaluate pearls according to their glossiness, interference color, and shape. However, the characteristics of their evaluations are not fully understood. Using pearl grading experiments, we investigate the consistency of novice (i.
View Article and Find Full Text PDFThe spatial luminance relationship between shading patterns and specular highlight is suggested to be a cue for perceptual translucency (Motoyoshi, 2010). Although local image features are also important for translucency perception (Fleming & Bulthoff, 2005), they have rarely been investigated. Here, we aimed to extract spatial regions related to translucency perception from computer graphics (CG) images of objects using a psychophysical reverse-correlation method.
View Article and Find Full Text PDFDichromacy is a color vision defect in which one of the three cone photoreceptors is absent. Individuals with dichromacy are called dichromats (or sometimes "color-blind"), and their color discrimination performance has contributed significantly to our understanding of color vision. Macaque monkeys, which normally have trichromatic color vision that is nearly identical to humans, have been used extensively in neurophysiological studies of color vision.
View Article and Find Full Text PDFIt has been argued that when an observer moves, a contingent retinal-image motion of a stimulus would strengthen the perceived glossiness. This would be attributed to the veridical perception of three-dimensional structure by motion parallax. However, it has not been investigated whether the effect of motion parallax is more than that of retinal-image motion of the stimulus.
View Article and Find Full Text PDF