Publications by authors named "Kouz K"

Background: Hypotension is associated with organ injury and death in surgical and critically ill patients. In clinical practice, treating hypotension remains challenging because it can be caused by various underlying haemodynamic alterations. We aimed to identify and independently validate endotypes of hypotension in big datasets of surgical and critically ill patients using unsupervised deep learning.

View Article and Find Full Text PDF

Background: Intraoperative hypotension is associated with acute kidney injury (AKI). Clinicians thus frequently use vasopressors, such as norepinephrine, to maintain blood pressure. However, vasopressors themselves might promote AKI.

View Article and Find Full Text PDF

Study Objective: We hypothesize that personalized perioperative blood pressure management maintaining intraoperative mean arterial pressure (MAP) above the preoperative mean nighttime MAP reduces perfusion-related organ injury compared to maintaining intraoperative MAP above 65 mmHg in patients having major non-cardiac surgery. Before testing this hypothesis in a large-scale trial, we performed this bicentric pilot trial to determine a) if performing preoperative automated nighttime blood pressure monitoring to calculate personalized intraoperative MAP targets is feasible; b) in what proportion of patients the preoperative mean nighttime MAP clinically meaningfully differs from a MAP of 65 mmHg; and c) if maintaining intraoperative MAP above the preoperative mean nighttime MAP is feasible in patients having major non-cardiac surgery.

Design: Bicentric pilot randomized trial.

View Article and Find Full Text PDF

Purpose: There are different techniques for ultrasound-guided central venous catheter (CVC) insertion. When using the conventional syringe-on-needle technique, the syringe needs to be removed from the needle after venous puncture to pass the guidewire through the needle into the vein. When, alternatively, using the wire-in-needle technique, the needle is preloaded with the guidewire, and the guidewire-after venous puncture-is advanced into the vein under real-time ultrasound guidance.

View Article and Find Full Text PDF

Background: It remains unknown whether there is a causal relationship between intraoperative hypotension and postoperative neurocognitive disorders. We tested the hypothesis that personalised-compared to routine-intraoperative blood pressure management reduces the incidence of postoperative neurocognitive disorders in patients having major noncardiac surgery.

Methods: In this single-centre trial, 328 elective major noncardiac surgery patients were randomly allocated to receive personalised blood pressure management (i.

View Article and Find Full Text PDF

The current S1 guidelines on the intraoperative clinical application of hemodynamic monitoring in patients scheduled for noncardiac surgery are presented based on a case report under the aspect of an optimized intraoperative anesthesiological management. The S1 guidelines were developed with the aim of identifying the questions on the intraoperative hemodynamic monitoring and management which are important for the routine daily clinical practice, to discuss them in a guideline group and to answer them based on the current state of scientific knowledge. The guidelines were written under the auspices of the German Society of Anesthesiology and Intensive Care Medicine (DGAI) and published by the AWMF in 2023 under the register number 001/049.

View Article and Find Full Text PDF

Intraoperative hypotension is common and associated with organ injury. Hypotension can not only occur during surgery, but also thereafter. After surgery, most patients are treated in post-anesthesia care units (PACU).

View Article and Find Full Text PDF

During surgery, various haemodynamic variables are monitored and optimised to maintain organ perfusion pressure and oxygen delivery - and to eventually improve outcomes. Important haemodynamic variables that provide an understanding of most pathophysiologic haemodynamic conditions during surgery include heart rate, arterial pressure, central venous pressure, pulse pressure variation/stroke volume variation, stroke volume, and cardiac output. A basic physiologic and pathophysiologic understanding of these haemodynamic variables and the corresponding monitoring methods is essential.

View Article and Find Full Text PDF

Study Objective: Processed electroencephalography (pEEG) may help clinicians optimize depth of general anesthesia. Avoiding excessive depth of anesthesia may reduce intraoperative hypotension and the need for vasopressors. We tested the hypothesis that pEEG-guided - compared to non-pEEG-guided - general anesthesia reduces the amount of norepinephrine needed to keep intraoperative mean arterial pressure above 65 mmHg in patients having vascular surgery.

View Article and Find Full Text PDF

Haemodynamic monitoring and management are cornerstones of perioperative care. The goal of haemodynamic management is to maintain organ function by ensuring adequate perfusion pressure, blood flow, and oxygen delivery. We here present guidelines on "Intraoperative haemodynamic monitoring and management of adults having non-cardiac surgery" that were prepared by 18 experts on behalf of the German Society of Anaesthesiology and Intensive Care Medicine (Deutsche Gesellschaft für Anästhesiologie und lntensivmedizin; DGAI).

View Article and Find Full Text PDF

Mobile health diagnostics have demonstrated effectiveness in detecting and managing chronic diseases. This method comparison study aims to assess the accuracy and precision of the previously evaluated OptiBP™ technology over a four-week study period. This device uses optical signals recorded by placing a patient's fingertip on a smartphone's camera to estimate blood pressure (BP).

View Article and Find Full Text PDF

Objectives: The IKORUS system (Vygon, Écouen, France) allows continuous monitoring of the urethral perfusion index (uPI) using a photoplethysmographic sensor mounted near the base of the balloon of a dedicated urinary catheter. We aimed to test the hypothesis that the uPI decreases during off-pump coronary artery bypass (OPCAB) surgery and to investigate the relationship between the uPI and macrocirculatory variables.

Design: Prospective observational study.

View Article and Find Full Text PDF

Flow-directed, balloon-tipped pulmonary artery catheters allow measuring cardiac output and other haemodynamic variables including intracardiac pressures. We propose classifying pulmonary artery catheters by generations and specifying additional measurement modalities. Based on the method used to measure cardiac output, pulmonary artery catheters can be classified into three generations: first-generation using intermittent pulmonary artery thermodilution; second-generation using a thermal filament for automated pulmonary artery thermodilution; and third-generation combining thermal filament-based automated pulmonary artery thermodilution and pulmonary artery pulse wave analysis.

View Article and Find Full Text PDF

Background: Intraoperative hypotension is associated with organ injury. Current intraoperative arterial pressure management is mainly reactive. Predictive haemodynamic monitoring may help clinicians reduce intraoperative hypotension.

View Article and Find Full Text PDF

Hypotension can occur before, during, and after surgery and is associated with postoperative complications. Anesthesiologists should thus avoid profound and prolonged hypotension. A crucial part of avoiding hypotension is accurate and tight blood pressure monitoring.

View Article and Find Full Text PDF

Background: Finger-cuff methods allow noninvasive continuous arterial pressure monitoring. This study aimed to determine whether continuous finger-cuff arterial pressure monitoring helps clinicians reduce hypotension within 15 min after starting induction of anesthesia and during noncardiac surgery. Specifically, this study tested the hypotheses that continuous finger-cuff-compared to intermittent oscillometric-arterial pressure monitoring helps clinicians reduce the area under a mean arterial pressure of 65 mmHg within 15 min after starting induction of anesthesia and the time-weighted average mean arterial pressure less than 65 mmHg during noncardiac surgery.

View Article and Find Full Text PDF

Purpose Of Review: The measurement of cardiac output ( CO ) is important in patients with circulatory shock. Pulse wave analysis (PWA) estimates CO continuously and in real-time using the mathematical analysis of the arterial pressure waveform. We describe different PWA methods and provide a framework for CO monitoring using PWA in critically ill patients.

View Article and Find Full Text PDF

Background: Perioperative hemodynamic management aims to optimize organ perfusion pressure and blood flow-assuming this ensures that oxygen delivery meets cellular metabolic needs. Cellular metabolic needs are reflected by energy expenditure. A better understanding of energy expenditure under general anesthesia could help tailor perioperative hemodynamic management to actual demands.

View Article and Find Full Text PDF
Article Synopsis
  • Intraoperative hypotension is when patients' blood pressure drops during surgery, which can lead to serious health problems.
  • Researchers wanted to understand why this happens in patients undergoing major abdominal surgery by using a method called machine learning.
  • They discovered six different types of low blood pressure during surgery, which could help doctors give better treatments to patients experiencing these issues.
View Article and Find Full Text PDF

Background: Intraoperative hypotension is common in patients having non-cardiac surgery and is associated with serious complications and death. However, optimal intraoperative blood pressures for individual patients remain unknown. We therefore aim to test the hypothesis that personalized perioperative blood pressure management-based on preoperative automated blood pressure monitoring-reduces the incidence of a composite outcome of acute kidney injury, acute myocardial injury, non-fatal cardiac arrest, and death within 7 days after surgery compared to routine blood pressure management in high-risk patients having major abdominal surgery.

View Article and Find Full Text PDF

Background: The NICCI system (Getinge, Gothenburg, Sweden) is a new noninvasive haemodynamic monitoring system using a finger sensor.

Objectives: We aimed to investigate the performance of the NICCI system to measure blood pressure and pulse pressure variation compared with intra-arterial measurements.

Design: A prospective method comparison study.

View Article and Find Full Text PDF

Background: Hypotension during induction of anaesthesia is associated with organ injury. Continuous arterial pressure monitoring might help reduce hypotension. We tested the hypothesis that continuous intra-arterial compared with intermittent oscillometric arterial pressure monitoring reduces hypotension during induction of anaesthesia in noncardiac surgery patients.

View Article and Find Full Text PDF

Background: Arterial hypertension is a worldwide public health problem. While it is currently diagnosed and monitored non-invasively using the oscillometric method, having the ability to measure blood pressure (BP) using a smartphone application could provide more widespread access to hypertension screening and monitoring. In this observational study in intensive care unit patients, we compared blood pressure values obtained using a new optical smartphone application (OptiBP™; test method) with arterial BP values obtained using a radial artery catheter (reference method) in order to help validate the technology.

View Article and Find Full Text PDF