Publications by authors named "Kortesniemi M"

Radiology is now predominantly a digital medium and this has extended the flexibility, efficiency and application of medical imaging. Achieving the full benefit of digital radiology requires images to be of sufficient quality to make a reliable diagnosis for each patient, while minimising risks from radiation exposure, and so involves a careful balance between competing objectives. When an optimisation programme is undertaken, a knowledge of patient doses from surveys can be valuable in identifying areas needing attention.

View Article and Find Full Text PDF

Artificial intelligence (AI) applications are becoming increasingly common in radiology. However, ensuring reliable operation and expected clinical benefits remains a challenge. A systematic testing process aims to facilitate clinical deployment by confirming software applicability to local patient populations, practises, adherence to regulatory and safety requirements, and compatibility with existing systems.

View Article and Find Full Text PDF

The effect of mammography measurement conditions was investigated to evaluate their impact on measurement uncertainties in clinical practice. The most prominent physical X-ray beam quantities i.e.

View Article and Find Full Text PDF

Purpose: A quality control (QC) system for dual-energy CT (DECT) was developed. The scope of the QC system was to monitor both the constancy of the CT images and the software used in calculating the DECT derived maps. Longitudinal analysis was based on a standard imaging protocol, a commercial multi-energy phantom, and a semi-automatic analysis tool.

View Article and Find Full Text PDF

Objective: Indication-specific optimum field-of-views (FOVs) have been assessed for CBCT scans of impacted maxillary canines and mandibular third molars, as 40∅ × 35 mm and 35∅ × 35 mm, respectively. The objective was to investigate possible changes in absorbed organs and effective doses, for these two imaging indications, performing CBCT examinations with optimum FOV sizes instead of commonly used FOVs. Additionally, radiation exposure-induced cancer risk was calculated for both imaging indications with optimum FOVs.

View Article and Find Full Text PDF

Purpose: This study aimed to develop a deep learning (DL) method for noise quantification for clinical chest computed tomography (CT) images without the need for repeated scanning or homogeneous tissue regions.

Methods: A comprehensive phantom CT dataset (three dose levels, six reconstruction methods, amounting to 9240 slices) was acquired and used to train a convolutional neural network (CNN) to output an estimate of local image noise standard deviations (SD) from a single CT scan input. The CNN model consisting of seven convolutional layers was trained on the phantom image dataset representing a range of scan parameters and was tested with phantom images acquired in a variety of different scan conditions, as well as publicly available chest CT images to produce clinical noise SD maps.

View Article and Find Full Text PDF

Purpose: Automatic image analysis algorithms have an increasing role in clinical quality assurance (QA) in medical imaging. Although the implementation of QA calculation algorithms may be straightforward at the development level, actual deployment of a new method to clinical routine may require substantial additional effort from supporting services. We sought to develop a multimodal system that enables rapid implementation of new QA analysis methods in clinical practice.

View Article and Find Full Text PDF

Metabolomics has rapidly been adopted as one of the key methods in nutrition research. This review focuses on the recent developments and updates in the field, including the analytical methodologies that encompass improved instrument sensitivity, sampling techniques and data integration (multiomics). Metabolomics has advanced the discovery and validation of dietary biomarkers and their implementation in health research.

View Article and Find Full Text PDF

Background: The purpose of this study was to determine whether radiological measurements of radial fracture position made in cone beam computed tomography (CBCT) projection images are comparable to those made on traditional radiographs and could potentially substitute them.

Methods: Sixteen patients with fractures of the distal radius referred for radiographs were recruited for an additional CBCT scan which was performed immediately afterwards. Projection images and volumetric data were saved from the CBCT scans.

View Article and Find Full Text PDF

Cone beam computed tomography (CBCT) may provide essential additional image guidance to endovascular abdominal aneurysm repair (EVAR) operations but also significant radiation exposure to patients if scans are not carefully optimized. The purpose of our study was to define the image quality requirements for intraoperative EVAR CBCT imaging and to optimize the CBCT exposure parameters accordingly. A Multi-Energy CT phantom simulating a large patient was used by replacing the central phantom cylinder with a custom water-filled insert including an EVAR stent.

View Article and Find Full Text PDF

Enzyme-assisted aqueous extraction (EAAE) is a green, and scalable method to produce oil and protein hydrolysates from fish. This study investigated the role of different parameters on emulsion formation, oil recovery, and the composition of crude oil during EAAE of Baltic herring (Clupea harengus membras). Fatty acid compositions, lipid classes, tocopherols, and oxidation status of the EAAE crude oils were studied.

View Article and Find Full Text PDF

Non-grapefruits with unique sensory properties and potential health benefits provide added value to fruit wine production. This study aimed to explore consumers' fruit wine preferences and descriptors for the varied fruit wines. First, 234 consumers participated in an online survey concerning their preferences for different wines (grape, blueberry, hawthorn, goji, , and apricot).

View Article and Find Full Text PDF

Anthocyanins, the red-orange to blue-violet colorants present in fruits, vegetables, and tubers, have antidiabetic properties expressed via modulating energy metabolism, inflammation, and gut microbiota. Acylation of the glycosyl moieties of anthocyanins alters the physicochemical properties of anthocyanins and improves their stability. Thus, acylated anthocyanins with probiotic-like property and lower bioavailability are likely to have different biological effects from nonacylated anthocyanins on diabetes.

View Article and Find Full Text PDF

This study investigated the volatile composition and aromatic features of passion fruit wines using a combination of gas chromatography-quadrupole mass spectrometry (GC-qMS), gas chromatography-Orbitrap-mass spectrometry (GC-Orbitrap-MS), electronic nose (E-nose) and sensory evaluation. The results showed that these passion fruit wines possessed different aromatic features confirmed by E-nose. Seventeen sulfur compounds and seventy-eight volatiles were detected in these passion fruit wines using GC-Orbitrap-MS and GC-qMS, respectively.

View Article and Find Full Text PDF

The effect of nonacylated and acylated anthocyanins on urinary metabolites in diabetic rats was investigated. Nonacylated anthocyanins extract from bilberries (NAAB) or acylated anthocyanins extract from purple potatoes (AAPP) was given to Zucker diabetic fatty (ZDF) rats for 8 weeks at daily doses of 25 and 50 mg/kg body weight. H NMR metabolomics was applied to study alterations in urinary metabolites from three time points (weeks 1, 4, and 8).

View Article and Find Full Text PDF

Lead shields are commonly used in X-ray imaging to protect radiosensitive organs and to minimise patient's radiation dose. However, they might also complicate or interfere with the examination, and even decrease the diagnostic value if they are positioned incorrectly. In this study, the radiation dose effect of waist half-apron lead shield was examined via Monte Carlo simulations of postero-anterior (PA) chest radiography examinations using a female anthropomorphic phantom.

View Article and Find Full Text PDF

Docosahexaenoic acid (DHA) is essential for health but easily oxidized. Yet the influence of DHA's exact location (sn-1, sn-2, or sn-3) in triacylglycerols on oxidative stability is currently unknown. This is the first study comparing oxidative stability of DHA in regio- and enantiopure triacylglycerols with or without RRR-α-tocopherol.

View Article and Find Full Text PDF

Human milk is an intricate, bioactive food promoting infant health. We studied the composition of human milk samples collected over an 8-month lactation using H NMR metabolomics. A total of 72 human breast milk samples were collected from ten Chinese mothers at eight different time points.

View Article and Find Full Text PDF

Objectives: Patients with univentricular heart defects require lifelong imaging surveillance. Recent advances in non-invasive imaging have enabled replacing these patients' routine catheterisation. Our objective was to describe the safety and cost savings of transition of a tertiary care children's hospital from routine invasive to routine non-invasive imaging of low-risk patients with univentricular heart defects.

View Article and Find Full Text PDF

Purpose: To determine the effects of patient vertical off-centering when using organ-based tube current modulation (OBTCM) in chest computed tomography (CT) with focus on breast dose.

Materials And Methods: An anthropomorphic adult female phantom with two different breast attachment sizes was scanned on GE Revolution EVO and Siemens Definition Edge CT systems using clinical chest CT protocols and anterior-to-posterior scouts. Scans with and without OBTCM were performed at different table heights (GE: centered, ±6 cm, and ± 3 cm; Siemens: centered, -6 cm, and ± 3 cm).

View Article and Find Full Text PDF

Purpose: Computed tomography (CT) image noise is usually determined by standard deviation (SD) of pixel values from uniform image regions. This study investigates how deep learning (DL) could be applied in head CT image noise estimation.

Methods: Two approaches were investigated for noise image estimation of a single acquisition image: direct noise image estimation using supervised DnCNN convolutional neural network (CNN) architecture, and subtraction of a denoised image estimated with denoising UNet-CNN experimented with supervised and unsupervised noise2noise training approaches.

View Article and Find Full Text PDF

Purpose: The aim of this study was to investigate the eye lens and whole-body radiation doses to interventional radiology and cardiology staff in two Finnish hospitals.

Methods: Simultaneous measurements of personal dose equivalent quantities H(3) and H(10) were conducted in clinical conditions during different radiological and cardiological interventional procedures. In order to study the feasibility to estimate eye lens dose with H(10) measured over the protective apron or thyroid shield, the ratio between measured H(3) and H(10) was investigated.

View Article and Find Full Text PDF

DHA is most often used in supplements either in its triacylglycerol or ethyl ester form. Currently, there is only little published data on the differences in the oxidative stability and α-tocopherol response between the two lipid structures, as well as on the oxidation patterns of pure DHA. This study investigated the oxidative stability, α-tocopherol response and oxidation pattern of DHA incorporated in triacylglycerols and as ethyl esters with an untargeted approach after oxidation at 50 °C in the dark.

View Article and Find Full Text PDF

Anthocyanins have been shown to have prebiotic properties. This study investigated the impact of nonacylated anthocyanins and acylated anthocyanins on fecal and cecal metabolites and colonic gut microbiota in diabetic state using H nuclear magnetic resonance (NMR) metabolomics and metagenomic sequencing. Zucker diabetic fatty rats fed with high-fat diet were gavaged with nonacylated anthocyanins extracted from bilberries (NAAB) or acylated anthocyanins extracted from purple potatoes (AAPP) at daily doses of 25 and 50 mg/kg body weight for 8 weeks.

View Article and Find Full Text PDF

The sensory and chemical profiles of commercial bog bilberry (BB) wines were investigated using a multi-analytical approach. Sensory test included scaling and check-all-that-apply (CATA) method with questions on liking of BB wine. The sensory data was correlated with their volatile compound profiles determined using gas chromatography coupled with quadrupole and orbitrap mass spectrometry (GC-Quadrupole/Orbitrap-MS).

View Article and Find Full Text PDF