This study aimed to determine the effect of photobiomodulation therapy induced by semiconductor laser irradiation on human dental pulp stem cell (hDPSC) proliferation and their differentiation into odontoblast-like cells (OLCs). The effects of various semiconductor laser irradiation conditions on hDPSCs were examined. Three groups were evaluated: a single laser irradiation at 6 h post-seeding, multiple laser irradiations up to four times every 4 days after the first dose, and a control with no laser irradiation.
View Article and Find Full Text PDFThis study aimed to assess the impact of different laser irradiation modes and photosensitizer types on the bactericidal efficacy of antimicrobial photodynamic therapy (aPDT). Dentin plates were prepared by sectioning the crown dentin of bovine teeth infected with (n = 11). Nine aPDTs involving the combination of three 1% solutions of photosensitizers (brilliant blue, BB; acid red, AR; and methylene blue, MB) and three irradiation modes of semiconductor lasers (50 mW for 120 s, 100 mW for 60 s, and 200 mW for 30 s) were performed for each infected dentin plate, and the control consisted of the specimens not applied with aPDT.
View Article and Find Full Text PDFThe aim of this study was to investigate the effect of laser irradiation to computer-aided design/computer-aided fabrication (CAD/CAM) resin blocks coated with a silane coupling agent on the bond strength between resin blocks and composite resin. The CAD/CAM resin blocks used in this study were Cerasmart 300 (GC) and Vita Enamic (Vita); they were cut into plates and then subjected to a series of treatments. After processing with a silane coupling agent, treatment with a semiconductor laser was performed at 3.
View Article and Find Full Text PDFAntimicrobial photodynamic therapy (aPDT) used to sterilize carious dentin may irritate pulp tissues because of tissue-penetrating laser and singlet oxygen generation. This study aimed to assess the effects of aPDT on rat pulp tissues. A cavity formed in a rat maxillary first molar was treated with aPDT.
View Article and Find Full Text PDFThe aim of this study was to clarify the effect of universal adhesive (UA) viscosity on the bond strength of resin composite to dentin prepared with Er:YAG laser. Four experimental UAs (SI-1, SI-2, SI-3, and SI-4) were developed by adding 1, 2, 3, and 4 wt/% nanosilica to BeautyBond Xtreme (Shofu), respectively. BeautyBond Xtreme was used as a control (SI-0).
View Article and Find Full Text PDFThis study aimed to clarify the effects of strontium (Sr), borate (BO), and silicate (SiO) on cell proliferative capacity, the induction of differentiation into odontoblast-like cells (OLCs), and substrate formation of human dental pulp stem cells (hDPSCs). Sr, BO, and SiO solutions were added to the hDPSC culture medium at three different concentrations, totaling nine experimental groups. The effects of these ions on hDPSC proliferation, calcification, and collagen formation after 14, 21, and 28 days of culture were evaluated using a cell proliferation assay, a quantitative alkaline phosphatase (ALP) activity assay, and Alizarin Red S and Sirius Red staining, respectively.
View Article and Find Full Text PDFThe purpose of this study was to examine toothbrush-induced abrasion of resin composite restorations fabricated with flowable resin composites of different viscosities in vitro. In this study, six types of flowable resin composites with different flowability (Beautifil Flow F02, F02; Beautifil Flow F10, F10; Beautifil Flow Plus F00, P00; Beautifil Flow Plus F03, P03; Beautifil Flow Plus X F00, X00; and Beautifil Flow Plus X F03, X03) were used. For the toothbrush abrasion test, the standard cavity (4 mm in diameter and 2 mm in depth) formed on the ceramic block was filled with each flowable resin composite (n = 10) and brushed for up to 40,000 strokes in a suspension containing commercial toothpaste under the conditions of 500 g load, 60 strokes/min, and 30 mm stroke distance.
View Article and Find Full Text PDFThe purpose of this multicenter clinical study was to compare the mid-term clinical effectiveness of direct resin composite restorations using one-step or two-step self-etch adhesives (1-SEAs or 2-SEAs). In total, 352 restorations of class I-V cavities and non-carious cervical lesions in vital teeth (1-SEAs; 52 cases, 2-SEAs; 300 cases) were placed at nine university hospitals and evaluated according to the modified USPHS criteria at baseline, and after 1, 2, and 3 years. The recall rates were 86.
View Article and Find Full Text PDFThis study aimed to investigate the effect of the multi-ion releasing paste (MP) on the acid resistance of the enamel surface of an extracted human tooth. Five kinds of MP were prepared according to the content (wt%) of S-PRG fillers: 0 wt% (MP0, control), 1 wt% (MP1), 5 wt% (MP5), 20 wt% (MP20), and 30 wt% (MP30). The buccal coronal surfaces of the extracted anterior teeth were polished with each kind of MP for 1 min.
View Article and Find Full Text PDFThe present study aimed to evaluate the dentin bond strengths of all-in-one adhesives in combination with flowable-resin-composites of different manufacturers. The materials used in this study were two all-in-one adhesives (BeautiBond Multi, BM, and Clearfil Bond SE ONE, SE) and four flowable resin composites (Clearfil Majesty ES Flow, CME; Estelite Flow Quick, EFQ; MI Flow II, MIF; and Beautifil Flow Plus F03, BFP). By combining each all-in-one adhesive and flowable resin composite, eight experimental groups were established.
View Article and Find Full Text PDFThe purpose of this study was to examine the effects of combining specific adhesive materials and various surface treatments on bonding durability and microleakage of vertically fractured roots. Adhesive models were prepared using bovine lower incisors. The experiment included the following five groups: SB-G group (control) (10% citric acid with 3% ferric chloride solution (10-3 solution) + an adhesive resin cement (4-META/MMA-TBB; Super-Bond)), EC group (self-cure bonding agent (UB) + core composite resin (EC)), EC-G group (10-3 solution + UB + EC), EC-P group (40% phosphate solution + UB + EC), and EC-E group (18% ethylenediaminetetraacetic acid (EDTA) solution + UB + EC).
View Article and Find Full Text PDFObjective: This study aimed to evaluate the effect of direct pulp capping using an experimental self-adhesive resin for direct pulp capping (SRD) containing silica and surface pre-reacted glass-ionomer (S-PRG) filler on pulpal healing and to monitor the dentin bridge formation in rat pulp 2-4 weeks after operation.
Methods: Five types of SRDs (SRD-0: S-PRG fillers 0 wt%; SRD-1: S-PRG fillers 9.1 wt%; SRD-2: S-PRG fillers 18.
The aim of this study was to examine the effect of various surface treatments on the bond strength of a resin luting agent and the surface roughness and surface energy of computer-aided design and computer-aided manufacturing (CAD/CAM) materials. Four types of CAD/CAM blocks (Shofu Block HC: BHC; GC Cerasmart: CER; VITA Enamic: ENA; and Lava Ultimate: LAV) were used. All blocks were randomly divided into eight groups based on the surface treatment as follows: no surface treatment (C), airborne-particle abrasion (AA), hydrofluoric acid etching (HA), silane coupling agent application (SL), AA/SL, HA/SL, AA/HA, and AA/HA/SL.
View Article and Find Full Text PDFThis study aimed to examine bactericidal effects of a new antimicrobial photodynamic therapy (aPDT) on dentin plates infected with Lactobacillus acidophilus (L. acidophilus). First, we measured the amount of reactive oxygen species (ROS) produced when new photosensitizer (PS), acid red (AR), and brilliant blue (BB) were irradiated with a semiconductor laser.
View Article and Find Full Text PDFThe purpose of the present study was to examine the effects of silane coupling treatment and airborne-particle abrasion (APA) on shear bond strength (SBS) between photo-cured bulk-fill flowable composite resin and 12% silver-palladium-copper-gold (Ag-Pd-CuAu) alloy using self-adhesive resin cement. The six experimental groups were compared using two-way analysis of variance (ANOVA) followed by Tukey Kramer's post-hoc test to compare SBS values among the six groups at a 95% confidence level. The SBS of APA groups was significantly higher than non-APA groups.
View Article and Find Full Text PDFThis report shows the healing process of an exposed pulp carbonised by CO laser irradiation prior to the application of a capping material. Six intact teeth from four volunteers were irradiated by CO laser and randomly capped with either an adhesive resin (SE bond) (n = 3) or calcium hydroxide-based cement (Dycal) (n = 3). The laser was operated in super-pulsed mode (power output, 0.
View Article and Find Full Text PDFWe aimed at examining the effects of a percentage of air/water in spray on the cutting efficiency of Er,Cr:YSGG laser for enamel and dentin. The intensity and frequency of irradiation were 3.0 W and 20 Hz for the enamel surface and 2.
View Article and Find Full Text PDFThe relationship between wear resistance and filler size or filler loading was clarified for the universal resin composite; however, their relationship in flowable resin composites has not been clarified. The purpose of this study was to investigate the effect of filler size and filler loading on wear of experimental flowable resin composites by using a cyclic loading device. Nine experimental flowable resin composites consisting of three different sizes (70, 200 and 400 nm) and loading (50, 55 and 60 wt%) of filler were prepared.
View Article and Find Full Text PDFThe aim of this study was to evaluate the bactericidal effect of antimicrobial photodynamic therapy (aPDT) on an infected dentin model. Dentin plates were prepared from extracted human molars and infected through immersion in a solution of Streptococcus mutans. The nine experimental groups consisted of two laser irradiation groups (650 nm laser: 650 laser and 940 nm laser: 940 laser), two photosensitizer groups (methylene blue: MB, and azulenocyanine: Azc), four aPDT groups (650 nm laser irradiation of MB: 650 laser-MB, 650 nm laser irradiation of Azc: 650 laser-Azc, 940 nm laser irradiation of MB: 940 laser-MB and 940 nm laser irradiation of Azc: 940 laser-Azc) and a control.
View Article and Find Full Text PDFThe aim of this study was to histologically evaluate direct pulp capping using different all-in-one adhesives in rat teeth. Five all-in-one adhesives and a control material (MTA) were used. Each material was applied on the exposed pulp, and each cavity was subsequently restored with the resin composite.
View Article and Find Full Text PDFWe examined shear bond strengths (SBSs) of various tooth-coating-materials including the experimental materials to dentin and demineralization resistance of a fractured adhesive surface after the SBS testing. Three resin-type tooth-coating-materials (BC, PRG Barrier Coat; HC, Hybrid Coat II; and SF, Shield force plus) and two glass-ionomer-type tooth-coating-materials (CV, Clinpro XT Varnish; and FJ, Fuji VII) were selected. The experimental PRG Barrier Coat containing 0, 17, and 33 wt% S-PRG filler (BC0, BC17, and BC33, respectively) were developed.
View Article and Find Full Text PDFThe purpose of this study was to evaluate pulpal healing and reparative dentin formation after 14 and 28 days in exposed rat pulp directly capped with an experimentally developed all-in-one adhesive containing surface reaction-type pre-reacted glass-ionomer (S-PRG) filler. The four experimental groups and the control group were compared using the Kruskal-Wallis test, followed by the Steel-Dwass post-hoc test to compare the histopathological score. The Mann-Whitney U test was used to compare the histopathological score at 14 and 28 days for each observation item.
View Article and Find Full Text PDFThe purpose of this study was to examine three- and two-body wear values of flowable resin composites for posterior restorations, using a mechanical loading device. The cavities prepared on flattened extracted molars were restored with flowable resin composites (Clearfil Majesty LV: MLV, Estelite Flow Quick: EFQ, Beautifil Flow Plus F00: BFP, and MI Fill: MIF) using accompanying adhesive systems. A universal resin composite (Clearfil Majesty) was used as a control.
View Article and Find Full Text PDFWe aimed to examine the effect of various adhesive systems on the bond strength of composite resin to enamel or dentin prepared with erbium, chromium: yttrium scandium gallium garnet (Er,Cr:YSGG) laser. Each laser-cut enamel or dentin surface was treated with a bonding agent (SBB, Group 1); self-etching primer (SBP) and SBB (Group 2 and control); phosphoric-acid (KET), SBP and SBB (Group 3); KET, sodium-hypochlorite (ADG), SBP and SBB (Group 4); all-in-one adhesive (TSB, Group 5); or KET, ADG and TSB (Group 6). The control group was only polished with wet silicon carbide papers.
View Article and Find Full Text PDF