Annu Int Conf IEEE Eng Med Biol Soc
November 2021
This paper describes the application of a proposed spiral coil to the transformer of a transcutaneous energy transfer system for a totally implantable artificial heart. To reduce the number of rectifier components in the power receiving circuit, the shape of the power receiving transformer was reviewed. The results indicated that the power transmission efficiency between the transformers was almost the same as that of the receiving transformer with the same shape.
View Article and Find Full Text PDFThe electromagnetic compatibility of implantable or wearable medical devices has often been evaluated using human phantoms to electrically mimic biological tissues. However, no currently existing test fixture can measure the electrical characteristics of gel-like materials. In this paper, we report the development of a new test fixture that consists of a coaxial tube whose outer conductor is divided along the axial direction into two sections, which facilitates filling and removal of gel-like materials in order to measure their electrical characteristics.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
August 2015
Human body communication (HBC) is a new communication technology that has presented potential applications in health care and elderly support systems in recent years. In this study, which is focused on a wearable transmitter and receiver for HBC in a body area network (BAN), we performed electromagnetic field analysis and simulation using the finite difference time domain (FDTD) method with various models of the human body. Further we redesigned a number of impedance-matched electrodes to allow transmission without stubs or transformers.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
August 2015
Transcutaneous energy transmission is useful for improving patient quality of life and for supplying energy to implantable devices noninvasively. To supply highly efficient energy transmission through the skin, it is necessary to increase the coupling factor between the coils and increase the inductance of each coil. In this study, the optimal shape required for the coils to increase the coupling factor was investigated.
View Article and Find Full Text PDFWhen patients are fitted with a totally implantable artificial heart (TAH), they need to be implanted with two additional devices: one for the transmission of energy and one for information. However, this is a cumbersome process that affects the quality of life of the recipient. Therefore, we investigated the use of electromagnetic coupling for the transmission of energy and information and the possibility of unifying two transcutaneous transformers for the simultaneous transmission of energy and information.
View Article and Find Full Text PDFTranscutaneous energy transmission (TET) that uses electromagnetic induction between the external and internal coils of a transformer is the most promising method to supply driving energy to a totally implantable artificial heart without invasion. Induction-heating (IH) cookers generate magnetic flux, and if a cooker is operated near a transcutaneous transformer, the magnetic flux generated will link with the external and internal coils of the transcutaneous transformer. This will affect the performance of the TET and the artificial heart system.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
April 2009
We proposed the calculation method of the ventilation threshold using the noncontact respirometry under pedal stroke motion. By the simultaneous measurement with the expiration gas analyzer, we examined the effectiveness of the proposal method. There was high correlation over 0.
View Article and Find Full Text PDFThis paper reports on the electromagnetic influences on the analysis of biological tissue surrounding a prototype energy transmission system for a wireless capsule endoscope. Specific absorption rate (SAR) and current density were analyzed by electromagnetic simulator in a model consisting of primary coil and a human trunk including the skin, fat, muscle, small intestine, backbone, and blood. First, electric and magnetic strength in the same conditions as the analytical model were measured and compared to the analytical values to confirm the validity of the analysis.
View Article and Find Full Text PDFThis paper reports on the current density and specific absorption rate (SAR) analysis of biological tissue surrounding an air-core transcutaneous transformer for an artificial heart. The electromagnetic field in the biological tissue is analyzed by the transmission line modeling method, and the current density and SAR as a function of frequency, output voltage, output power, and coil dimension are calculated. The biological tissue of the model has three layers including the skin, fat, and muscle.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
March 2008
This paper reports on the electromagnetic influences on the analysis of biological tissue surrounding a prototype energy transmission system for a wireless capsule endoscope. Specific absorption rate (SAR) and current density were analyzed by electromagnetic simulator in a model consisting of primary coil and a human trunk including the skin, fat, muscle, small intestine, blood and backbone. SAR and current density as a function of frequency and output power were analyzed.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
March 2008
We proposed the non-contact measurement method of the respiratory movement under pedal stroke motion, by the application of optical technique. By the simultaneous measurement with the expiration gas analyzer, we examined the effectiveness of the proposal method. As the results, we clarified that the calculated value obtained by our proposal method is highly correlated with the tidal volume expiration measured by the expiration gas analyzer.
View Article and Find Full Text PDFThis paper reports on the specific absorption rate (SAR) and the current density analysis of biological tissue surrounding an air-core type of transcutaneous transformer for an artificial heart. The electromagnetic field in the biological tissue surrounding the transformer was analyzed by the transmission-line modeling method, and the SAR and current density as a function of frequency (200k-1 MHz) for a transcutaneous transmission of 20 W were calculated. The model's biological tissue has three layers including the skin, fat and muscle.