Objectives: The purpose of the present prospective case series was to investigate the clinical and radiological outcome of one-piece zirconia implants fabricated from 3Y-TZP with a moderately roughened endosseous surface (Sa = 1.24 μm) to support three-unit fixed dental prostheses (FDP) after five years in function.
Materials And Methods: Twenty-seven patients received a total of 54 implants in a one-stage surgery with immediate provisionalization.
The present study investigated the in vivo aging of yttria-stabilized zirconia (YSZ) oral implants (ZiUnite®) removed after 37 to 181 months. These implants featured a porous zirconia surface to enhance osseointegration. They were placed in prospective clinical investigations and had to be explanted due to peri‑implant bone breakdown.
View Article and Find Full Text PDF: The objective of this study was to compare the trueness and precision of three intraoral scanners (IOSs) for the digitization of dentate and edentulous maxillectomy and mandibulectomy defects in artificial models. Four representative defect models-a dentate and an edentulous maxillectomy model and a dentate and an edentulous mandibulectomy model-were used for digital scanning. After a reference scan of each model, they were scanned with three IOSs: CEREC AC Omnicam, True Definition, and cara TRIOS 3.
View Article and Find Full Text PDFObjectives: Single midline implants in the edentulous mandible can be used to support existing complete dentures to improve patients' satisfaction and masticatory efficiency. The impact on patients' dietary habits and the influence of the loading protocol of the implants was the subject of this study.
Materials And Methods: In this prospective randomized clinical trial, edentulous patients with existing complete dentures in both jaws were treated with a single midline implant in the mandible.
Objectives: There is a paucity of data on the outcome of fixed tooth- and implant-supported porcelain-fused-to-metal (PFM) and ceramic-based (CB) restorations fabricated during undergraduate dental education. Therefore, this retrospective study examined the outcome of fixed restorations placed in patients participating in an undergraduate program.
Methods: Patient records were searched for data on fixed PFM and CB restorations.
Preclinical and clinical research on two-piece zirconia implants are warranted. Therefore, we evaluated the in vitro fracture resistance of such a zirconia oral implant system. The present study comprised 32 two-piece zirconia implants and abutments attached to the implants using a titanium ( = 16) or a zirconia abutment screw ( = 16).
View Article and Find Full Text PDFFyn, Blk, and Lyn are part of a group of proteins called Src family kinases. They are crucial in controlling cell communication and their response to the growth, changes, and immune system. Blocking these proteins with inhibitors can be a way to treat diseases where these proteins are too active.
View Article and Find Full Text PDFObjectives: Surface characteristics of implant reconstructions determine the gingival fibroblast (GF) response and thus soft tissue integration (STI). However, for monolithic implant reconstructions it is unknown whether the (hybrid) ceramic biomaterial type and its surface treatment affect GF response. Therefore, this investigation examined the influence of the implant reconstruction biomaterials hybrid ceramic (HC), lithium disilicate ceramic (LS), 4 and 5 mol% yttria partially stabilized zirconiumdioxide ceramics (4/5Y-PSZ) and their surface treatment - machining, polishing or glazing - on surface characteristics and GF response.
View Article and Find Full Text PDFProtein tyrosine phosphatases (PTPs) are the class of dephosphorylation enzymes that catalyze the removal of phosphate groups from tyrosine residues on proteins responsible for various cellular processes. Any disbalance in signal pathways mediated by PTPs leads to various disease conditions like diabetes, obesity, cancers, and autoimmune disorders. Amongst the PTP superfamily, PTP1B, SHP2, Cdc25, and LMW-PTP have been prioritized as druggable targets for developing medicinal agents.
View Article and Find Full Text PDFCancer is indeed considered a hazardous and potentially life-threatening disorder. The JAK/STAT pathway is an important intracellular signaling cascade essential for many physiological functions, such as immune response, cell proliferation, and differentiation. Dysregulation of this pathway aids in the progression and development of cancer.
View Article and Find Full Text PDFUnlabelled: The purpose of the present study was to assess the fracture resistance of a two-piece alumina-toughened zirconia implant system with a carbon-reinforced PEEK abutment screw.
Methods: Thirty-two implants with screw-retained zirconia abutments were divided into four groups of eight samples each. Group 0 (control group) was neither loaded nor aged in a chewing simulator; group H was hydrothermally aged; group L was loaded with 98 N; and group HL was subjected to both hydrothermal aging and loading in a chewing simulator.
The use of hybrid abutment crowns bonded extraorally to a titanium bonding base has aesthetic and biological benefits for the prosthetic rehabilitation of oral implants. The objective of this study was to evaluate the effects of luting agents between a zirconium dioxide crown and the titanium bonding base on crown/abutment retention and the subsequent durability of the prosthetic superstructure. Fifty-six implant abutment samples, all restored with a lower first premolar zirconium dioxide crown, were used and divided into seven groups ( = 8/group) according to the type of luting agent used: group 1, SpeedCEM Plus; group 2, Panavia SA Cement Universal; group 3, Panavia V5; group 4, RelyX Unicem 2 Automix; group 5, VITA ADIVA IA-Cem; group 6, Ketac CEM; and group 7, Hoffmann's Phosphate Cement.
View Article and Find Full Text PDFThe use of computerized optical impression making (COIM) for the fabrication of removable dentures for partially edentulous jaws is a rising trend in dental prosthetics. However, the accuracy of this method compared with that of traditional impression-making techniques remains uncertain. We therefore decided to evaluate the accuracy of COIM in the context of partially edentulous jaws in an in vivo setting.
View Article and Find Full Text PDFThe aim of this in vitro study was to evaluate the long-term stability of one-piece diameter reduced zirconia oral implants under the influence of loading and artificial aging in a chewing simulator as well as the fracture load in a static loading test. Thirty-two one-piece zirconia implants with a diameter of 3.6 mm were embedded according to the ISO 14801:2016 standard.
View Article and Find Full Text PDFThe intention of this 5-year prospective cohort investigation was to clinically and radiographically investigate the outcomes of a one-piece zirconia implant system for single tooth replacement. Sixty-five patients received a total of 66 single-tooth implants. All implants immediately received temporary restorations and were finally restored with all-ceramic crowns.
View Article and Find Full Text PDFObjectives: This study aimed to describe a disability-simulating learning unit (DSLU) to raise dental students' awareness of the special needs of patients with disabilities as well as to measure the effect of the DSLU on ableism.
Methods: A DSLU among final-year undergraduate dental students (n = 33), was developed and evaluated. The students were randomly divided into two groups (Group I, n = 17; Group II, n = 16).
Background: When dental patients seek care, treatments are not always successful,that is patients' oral health problems are not always eliminated or substantially reduced. Identifying these patients (treatment non-responders) is essential for clinical decision-making. Group-based trajectory modeling (GBTM) is rarely used in dentistry, but a promising statistical technique to identify non-responders in particular and clinical distinct patient groups in general in longitudinal data sets.
View Article and Find Full Text PDFThe objective was to investigate the clinical and radiological outcome of one-piece zirconia oral implants to support three-unit fixed dental prostheses (FDP) after three years in function. Twenty-seven patients were treated with a total of 54 implants in a one-stage surgery and immediate provisionalization. Standardized radiographs were taken at implant placement, after one year and after three years, to evaluate peri-implant bone loss.
View Article and Find Full Text PDFStatement Of Problem: Making conventional facial impressions can be uncomfortable for the patient and complicated for the prosthodontist. Using facial scanners to digitize faces is an alternative approach. However, the initial costs of the equipment have prevented their widespread use in dental practice, and the accuracy of ear scanning is unclear.
View Article and Find Full Text PDFAs the use of zirconia-based nano-ceramics is rising in dentistry, the examination of possible biological effects caused by released nanoparticles on oral target tissues, such as bone, is gaining importance. The aim of this investigation was to identify a possible internalization of differently sized zirconia nanoparticles (ZrNP) into human osteoblasts applying Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS), and to examine whether ZrNP exposure affected the metabolic activity of the cells. Since ToF-SIMS has a low probing depth (about 5 nm), visualizing the ZrNP required the controlled erosion of the sample by oxygen bombardment.
View Article and Find Full Text PDFPurpose: To compare the feasibility and accuracy of using intraoral scanners to digitize a maxillary defect model simulating various trismus conditions.
Materials And Methods: Four intraoral scanners were used to digitize a maxillary defect model simulating four different degrees of trismus (mouth opening = 10, 20, 30, and 40 mm), and the scanned areas were compared. The scans were also superimposed on each other for precision analysis and on reference data for trueness analysis using 3D evaluation software.
Objective: To investigate the fracture strength and potential phase transformation of an injection-molded two-piece zirconia implant restored with a zirconia abutment after loading and/or aging.
Methods: Thirty-two two-piece zirconia implants (4.0 mm diameter) restored with zirconia abutments were embedded according to ISO 14801 and divided into four groups (n = 8/group): Three groups were either exclusively hydrothermally treated (group HT; 85°C), dynamically loaded (group DL; 10 cycles; 98 N), or subjected to both treatments simultaneously (group DL/HT).
Polyether ether ketone (PEEK) has been introduced into implant dentistry as a viable alternative to current implant abutment materials. However, data on its physico-mechanical properties are still scarce. The present study sought to shed light on this topic utilizing an ex vivo chewing simulator model.
View Article and Find Full Text PDFPurpose: Based on the excellent long-term data, dental implants made of titanium are considered the international implantological standard for replacing missing teeth. However, ceramic implants made of zirconia (ZrO) have experienced a renaissance in the last 15 years due to constant innovations in materials and products, with material properties and soft tissue- and osseointegration behavior comparable to those of titanium. However, one limitation concerning ceramic implants is the lack of reliable long-term data, especially in the case of two-piece implant systems.
View Article and Find Full Text PDF