We developed an algorithm for automatically analyzing scattering-based light sheet microscopy (sLSM) images of anal squamous intraepithelial lesions. We developed a method for automatically segmenting sLSM images for nuclei and calculating seven features: nuclear intensity, intensity slope as a function of depth, nuclear-to-nuclear distance, nuclear-to-cytoplasm ratio, cell density, nuclear area, and proportion of pixels corresponding to nuclei. 187 images from 80 anal biopsies were used for feature analysis and classifier development.
View Article and Find Full Text PDFDemand for anal cancer screening is expected to rise following the recent publication of the Anal Cancer-HSIL Outcomes Research trial, which showed that treatment of high-grade squamous intraepithelial lesions significantly reduces the rate of progression to anal cancer. While screening for human papillomavirus-associated squamous lesions in the cervix is well established and effective, this is less true for other sites in the lower anogenital tract. Current anal cancer screening and prevention rely on high-resolution anoscopy with biopsies.
View Article and Find Full Text PDFBackground: Previous research suggested that the method of adjustment and forced choice variants of the subjective visual vertical (SVV) produce comparable estimates of both bias and variability. However, variants of the SVV that utilize a method of adjustment procedure are known to be heavily influenced by task parameters, including the stimulus rotation speed, which was not accounted for in previous SVV research comparing the method of adjustment to forced-choice.
Objective: The aim of the present study was to determine if (1) the SVV with a forced-choice procedure produces both bias and variability estimates that are comparable to those obtained using a method of adjustment procedure, (2) to see if rotation speed impacts the comparability of estimates and (3) quantify correlations between the estimates produced by different procedures.
Homoeostatic metaplasticity is a neuroprotective physiological feature that counterbalances Hebbian forms of plasticity to prevent network destabilization and hyperexcitability. Recent animal models highlight dysfunctional homoeostatic metaplasticity in the pathogenesis of Alzheimer's disease. However, the association between homoeostatic metaplasticity and cognitive status has not been systematically characterized in either demented or non-demented human populations, and the potential value of homoeostatic metaplasticity as an early biomarker of cognitive impairment has not been explored in humans.
View Article and Find Full Text PDFWhen making decisions, people naturally ask two implicit questions: how soon can I make a decision, and how certain am I? In perception, people's confidence (how certain?) shows a nonmonotonic relationship with response time (how soon?), such that choice confidence can either increase or decrease with response time. Although a frontoparietal network has been implicated as a neural substrate that binds choice confidence and action (e.g.
View Article and Find Full Text PDFHumans can subjectively yet quantitatively assess choice confidence based on perceptual precision even when a perceptual decision is made without an immediate reward or feedback. However, surprisingly little is known about choice confidence. Here we investigate the dynamics of choice confidence by merging two parallel conceptual frameworks of decision making, signal detection theory and sequential analyses (i.
View Article and Find Full Text PDFWhen making perceptual decisions, humans have been shown to optimally integrate independent noisy multisensory information, matching maximum-likelihood (ML) limits. Such ML estimators provide a theoretic limit to perceptual precision (i.e.
View Article and Find Full Text PDFPrior studies show that visual motion perception is more precise than vestibular motion perception, but it is unclear whether this is universal or the result of specific experimental conditions. We compared visual and vestibular motion precision over a broad range of temporal frequencies by measuring thresholds for vestibular (subject motion in the dark), visual (visual scene motion) or visual-vestibular (subject motion in the light) stimuli. Specifically, thresholds were measured for motion frequencies spanning a two-decade physiological range (0.
View Article and Find Full Text PDFVestibular perceptual thresholds are defined by a dynamic sensory system. To capture these dynamics, thresholds were previously fit as a function of frequency. In this paper, we compare fits using two published models with two new models.
View Article and Find Full Text PDFVestibular symptoms caused by migraine, referred to as vestibular migraine, are a frequently diagnosed but poorly understood entity. Based on recent evidence that normal subjects generate vestibular-mediated percepts of head motion and reflexive eye movements using different mechanisms, we hypothesized that percepts of head motion may be abnormal in vestibular migraine. We therefore measured motion detection thresholds in patients with vestibular migraine, migraine patients with no history of vestibular symptoms, and normal subjects using the following paradigms: roll rotation while supine (dynamically activating the semicircular canals); quasi-static roll tilt (statically activating the otolith organs); and dynamic roll tilt (dynamically activating the canals and otoliths).
View Article and Find Full Text PDFThe stereocilium is the basic sensory unit of nature's mechanotransducers, which include the cochlear and vestibular organs. In noisy environments, stereocilia display high sensitivity to miniscule stimuli, effectively dealing with a situation that is a design challenge in micro systems. The gating spring hypothesis suggests that the mechanical stiffness of stereocilia bundle is softened by tip-link gating in combination with active bundle movement, contributing to the nonlinear amplification of miniscule stimuli.
View Article and Find Full Text PDF