An 86-year-old man was hospitalized urgently to our department because of his worsening hemoptysis. He had undergone open thoracic aortic grafting for the Stanford type B chronic aortic dissecting aneurysm 30 years earlier. Contrast enhanced computed tomography (CT) revealed the distal anastomotic aneurysm, leakage of the contrast medium around the distal anastomotic site.
View Article and Find Full Text PDFA 69-year-old man was hospitalized urgently to the department of cardiology, with the progressive general malaise. On admission, his blood pressure was 80/42 mmHg, his white cell count 13,700/µl, and C-reactive protein 25.55 mg/dl suggesting existence of aggressive infection with impaired circulation.
View Article and Find Full Text PDFTo prevent pulmonary embolism due to deep venous thrombosis (DVT), we have treated 611 patients undergoing orthopedic surgery of the lower extremities with our protocol including pre- and postoperative ultrasonic venous screening and anticoagulant therapy if necessary. A total of 118 patients (19.3%) developed DVT.
View Article and Find Full Text PDFPurpose: We report a technique to place Gore-TAG (TAG) precisely just below the origin of the neck vessel without overstenting.
Technique: Before deploying TAG, retrograde insertion of the protection sheath through the left subclavian artery (LSCA), or the left common carotid artery (LCCA), into the aortic arch was accomplished. The proximal flare portion of TAG catheter was positioned to touch or partially cross the protection sheath.
Ann Thorac Cardiovasc Surg
December 2005
A 61-year-old man presented with consistent hemolytic anemia 15 months after ascending and total arch replacement for DeBakey I type acute aortic dissection. The cause of hemolysis turned out to be mechanical damage of red blood cells at the inverted felt of the proximal anastomosis. Reoperation of resection of the felt and repair of the proximal anastomosis successfully resolved this problem.
View Article and Find Full Text PDFAn 87-year-old man underwent aorto-bifemoral bypass using a bifurcated Bionit II knitted Dacron graft for high aortic occlusion in 1987 at another hospital. In November, 2004, he was admitted to our institution because of difficulty in walking due to swelling and tenderness in the right groin. Computed tomography (CT) scan indicated bilateral aneurysms of the grafts in the groins.
View Article and Find Full Text PDFAnn Thorac Cardiovasc Surg
June 2005
We report a rare case of severe hemolytic anemia accompanied by moderate renal insufficiency after mitral valve repair. Although the degree of the residual mitral regurgitation was less than 1+ during the first three weeks after the operation, the maximum lactate dehydrogenase (LDH) was up to 7,430 U/l and the minimum hemoglobin was 4.9 g/dl.
View Article and Find Full Text PDFAn 83-year-old woman was transferred to our hospital because of pacing failure and suspected ventricular perforation by a permanent pacing lead. She had undergone permanent pacemaker implantation 5 months previously. Chest radiography showed the pacing lead running out of the cardiac shadow.
View Article and Find Full Text PDF