Publications by authors named "Klonoff D"

Background: Continuous glucose monitoring (CGM) is a tool widely used in the treatment of patients with type 1 diabetes. The purpose of the current study was to evaluate whether accuracy and patient treatment satisfaction differ between the Enlite™ (Medtronic MiniMed, Inc., Northridge, CA) and Dexcom(®) (San Diego, CA) G4 PLATINUM CGM sensors.

View Article and Find Full Text PDF

Background: Previous studies have shown that heating the insulin injection site may accelerate insulin absorption. We investigated the pharmacological profile of insulin administered with InsuPatch, a local skin-heating device.

Methods: In this randomized, crossover study carried out in 56 subjects with type 1 diabetes treated with insulin pump [mean age 32 ± 13.

View Article and Find Full Text PDF

Background: The ASPIRE in-clinic study established that automatic suspension of insulin with the threshold suspend (TS) feature reduces the duration of induced hypoglycemia. The study's crossover design allowed the effects of antecedent hypoglycemia to be studied.

Subjects And Methods: The study enrolled 50 subjects who exercised until plasma glucose (YSI glucose and lactate analyzer; YSI, Inc.

View Article and Find Full Text PDF

Background: The Parkes error grid, which was developed in 1994, presented performance zones for blood glucose (BG) monitors with borders that were not mathematically specified at the time the grid was published.

Methods: In this article, we (1) review the history of the Parkes error grid, (2) present the never-before-published exact coordinates and specifications of the grid so that others may produce an exact replica of the original grid, and (3) discuss our suggestions how this metric should be applied.

Results: The new ISO15197:2013 guideline for system accuracy assessment of BG meters for patient self-measurement incorporates use of this metric for defining acceptable accuracy of BG monitors.

View Article and Find Full Text PDF

Blood glucose monitors (BGMs) are approved by regulatory agencies based on their performance during strict testing conducted by their manufacturers. However, after approval, there is uncertainty whether BGMs maintain the accuracy levels that were achieved in the initial data. The availability of inaccurate BGM systems pose a public health problem because their readings serve as a basis for treatment decisions that can be incorrect.

View Article and Find Full Text PDF

Nocturnal hypoglycemia is a barrier to therapy intensification efforts in diabetes. The Paradigm® Veo™ system may mitigate nocturnal hypoglycemia by automatically suspending insulin when a prespecified sensor glucose threshold is reached. ASPIRE (Automation to Simulate Pancreatic Insulin REsponse) In-Home (NCT01497938) was a multicenter, randomized, parallel, adaptive study of subjects with type 1 diabetes.

View Article and Find Full Text PDF

This paper discusses the results of a survey on the usability of a new half-unit insulin pen, JuniorSTAR (CE mark pending, under the responsibility of Haselmeier), in children with type 1 diabetes. Insulin pen devices have advantages over the traditional vial-and-syringe method of insulin delivery, including improved patient satisfaction and adherence, greater ease of use and superior accuracy, especially when delivering small doses of insulin. The accuracy and design of insulin pens is particularly important in the paediatric population.

View Article and Find Full Text PDF

Purpose: The purpose of this project was to determine how prevalent control solution calibration is in patients who perform self-monitoring of blood glucose (SMBG).

Methods: Eighteen patients with or parents of children with type 1 diabetes mellitus were surveyed to gauge patients' knowledge of control testing and the prevalence of its use. U.

View Article and Find Full Text PDF

Currently patients with diabetes comprise up to 25-30% of the census of adult wards and critical care units in our hospitals. Although evidence suggests that avoidance of hyperglycemia (>180 mg/dL) and hypoglycemia (<70 mg/dL) is beneficial for positive outcomes in the hospitalized patient, much of this evidence remains controversial and at times somewhat contradictory. We have recently formed a consortium for Planning Research in Inpatient Diabetes (PRIDE) with the goal of promoting clinical research in the area of management of hyperglycemia and diabetes in the hospital.

View Article and Find Full Text PDF

Background: The threshold-suspend feature of sensor-augmented insulin pumps is designed to minimize the risk of hypoglycemia by interrupting insulin delivery at a preset sensor glucose value. We evaluated sensor-augmented insulin-pump therapy with and without the threshold-suspend feature in patients with nocturnal hypoglycemia.

Methods: We randomly assigned patients with type 1 diabetes and documented nocturnal hypoglycemia to receive sensor-augmented insulin-pump therapy with or without the threshold-suspend feature for 3 months.

View Article and Find Full Text PDF

mHealth is an emerging concept in health care and uses mobile communications devices for health services and information. Mobile phones, patient monitoring devices, tablets, personal digital assistants, and other wireless devices can be part of mHealth systems. With mHealth systems, glucose data can now be automatically collected, transmitted, aggregated with other physiologic data, analyzed, stored, and presented as actionable information.

View Article and Find Full Text PDF

Underutilization of glucose data and lack of easy and standardized glucose data collection, analysis, visualization, and guided clinical decision making are key contributors to poor glycemic control among individuals with type 1 diabetes mellitus. An expert panel of diabetes specialists, facilitated by the International Diabetes Center and sponsored by the Helmsley Charitable Trust, met in 2012 to discuss recommendations for standardizing the analysis and presentation of glucose monitoring data, with the initial focus on data derived from continuous glucose monitoring systems. The panel members were introduced to a universal software report, the Ambulatory Glucose Profile, and asked to provide feedback on its content and functionality, both as a research tool and in clinical settings.

View Article and Find Full Text PDF

Abstract Underutilization of glucose data and lack of easy and standardized glucose data collection, analysis, visualization, and guided clinical decision making are key contributors to poor glycemic control among individuals with type 1 diabetes. An expert panel of diabetes specialists, facilitated by the International Diabetes Center and sponsored by the Helmsley Charitable Trust, met in 2012 to discuss recommendations for standardization of analysis and presentation of glucose monitoring data, with the initial focus on data derived from CGM systems. The panel members were introduced to a universal software report, the Ambulatory Glucose Profile (AGP), and asked to provide feedback on its content and functionality, both as a research tool and in clinical settings.

View Article and Find Full Text PDF

Objectives: The primary objective of this study was to investigate the dosing accuracy of the new prefilled FlexTouch insulin pen (FT) in comparison to conventional vial and syringe (V&S) when used by patients (Pts), caregivers (CG) and healthcare professionals (HCPs).

Methods: A total of 120 subjects participated in the trial (40 diabetes patients aged 61 ± 11 [mean ± SD] yrs, 20 caregivers [parents and other relatives], 20 physicians, and 40 nurses/certified diabetes educators). The participants were introduced to the devices in randomized order and were asked to perform injections of 5, 25, 43 and 79 IU doses into laboratory tubes.

View Article and Find Full Text PDF

Fluorescence represents a promising alternative technology to electrochemistry and spectroscopy for accurate analysis of glucose in diabetes; however, no implanted fluorescence glucose assay is currently commercially available. The method depends on the principle of fluorescence, which is the emission of light by a substance after absorbing light. A fluorophore is a molecule that will absorb energy of a specific wavelength and reemit energy at a different wavelength.

View Article and Find Full Text PDF