Low-density lipoprotein (LDL) apheresis is effective and safe for patients with diabetes, proteinuria, and dyslipidemia. Diabetes mellitus is accompanied by ocular microvascular complications like retinal neovascularization or diabetic macular edema. These are leading causes of blindness and can be mediated by abnormal vessel growth and increased vascular permeability due to elevated levels of vascular endothelial growth factor (VEGF) in diabetic patients.
View Article and Find Full Text PDFBackground: To evaluate if a combination therapy with micropulse diode laser (MPL) shows non-inferiority on visual acuity (BCVA) within 12 months in comparison to standard therapy, i.e. intravitreal injection of ranibizumab alone.
View Article and Find Full Text PDFJ Cataract Refract Surg
August 2005
Purpose: To investigate the reliability of corneal topography measurements using the Orbscan II topography system (Bausch & Lomb) not only referring to a normal cohort but also to different refractive conditions.
Setting: Department of Ophthalmology, Ruprecht-Karls-University of Heidelberg, Heidelberg, Germany.
Methods: Eighty patients (mean age 46.
J Cataract Refract Surg
February 2005
Purpose: To assess the correlation between continuous curvilinear capsulorhexis (CCC) size and visual outcomes in patients with an accommodating intraocular lens (IOL).
Setting: Heidelberg IOL and Refractive Surgery Research Group, Department of Ophthalmology, Ruprecht-Karls-University of Heidelberg, Heidelberg, Germany.
Methods: Nineteen eyes had phacoemulsification and implantation of a 1CU accommodating IOL (HumanOptics AG).
J Cataract Refract Surg
November 2003
Purpose: To evaluate the anterior chamber depth (ACD) according to refractive status, assess the reliability of repeated ACD measurements using the Orbscan II Topography System (Bausch and Lomb), compare Orbscan II and IOLMaster (Carl Zeiss Meditec AG) ACD measurements, and investigate the correlation between refraction, axial length (AL), and ACD.
Setting: Department of Ophthalmology, Ruprecht-Karls-University of Heidelberg, Heidelberg, Germany.
Methods: In this clinical study, 60 patients with a mean age of 43.
Purpose: To quantitatively evaluate and compare intraocular lenses (IOLs) with a round or sharp optic edge design for posterior capsule opacification (PCO).
Study Design: Prospective comparative observational case series. PARTICIPANTS/MATERIALS: Photographs from 174 eyes were analyzed for PCO at the Department of Ophthalmology, Ruprecht-Karls-University of Heidelberg, Heidelberg, Germany.