Publications by authors named "Kiyonari Inamura"

First, history of PACS (picture archiving and communication system for medical use) in Japan is described in two parts: in part 1, the early stage of PACS development from 1984 to 2002, and in part 2 the matured stage from 2002 to 2010. PACS in Japan has been developed and installed by local manufacturers by their own technology and demand from domestic hospitals. Part 1 mainly focuses on quantitative growth and part 2 on qualitative change.

View Article and Find Full Text PDF

The aim of this study is to clarify the change over time in the elements of work (job elements) and their features, as well as the relationship between job elements and the type of job, job class, and the role of the hospital they are performed in. A time-motion study was conducted on the medical staff in the surgical wards of two hospitals. An analysis of roles bys by (a) type or class of job type, and (b) hospital function was conducted.

View Article and Find Full Text PDF

The purposes of this study were first to develop a system which statistically tests results of radiotherapy and which automatically acquires an optimal discrete-valued attribute by dividing and grouping continuous-valued attributes, and second to find the optimal range of values such as tumor dose by taking account of the conditions and statistics in ROGAD (Radiation Oncology Greater Area Database), a multi-institutional database in Japan. Our ultimate goal is to assist clinical decision making for every patient. In this research, two algorithms for acquiring a boundary value were developed without detecting false boundaries or accidental errors of acquired boundaries.

View Article and Find Full Text PDF
Article Synopsis
  • The Radiation Oncology Greater Area Database (ROGAD) was established in 1991 by the Japanese Society for Therapeutic Radiology and Oncology to improve treatment strategies and planning by analyzing radiotherapy data.* -
  • ROGAD collected over 13,000 cases from 325 facilities between 1992 and 2001, highlighting its role in quality assurance and the assessment of new technologies in radiation therapy.* -
  • To accommodate different facility protocols, the Virtual Private Database System (VPDS) was created, allowing oncologists to manage data as if it were exclusive to their facility while still being part of the overarching ROGAD system.*
View Article and Find Full Text PDF

We designed a new medical information event model and developed a time-oriented data warehouse based on the model. Here, the medical information event in a basic data unit is handled by a medical information system. The timing of decision making and treatment for a patient in the processing of his medical information is sometimes very critical.

View Article and Find Full Text PDF

The target of our study is to establish the methodology for analyzing level of security requirements, for searching suitable security measures and for optimizing security distribution to every portion of medical practice. Quantitative expression must be introduced to our study as possible for the purpose of easy follow up of security procedures and easy evaluation of security outcomes or results. Results of system analysis by fault tree analysis (FTA) clarified that subdivided system elements in detail contribute to much more accurate analysis.

View Article and Find Full Text PDF

There are many cases in which picture archiving and communication systems (PACS) are built with old-type existing modalities with no DICOM output. One of the methods for interfacing them to the PACS is to implement video capture (/ frame grabber) equipment. This equipment takes analog video signal output from medical imaging modalities, and amplitude of the video signal is A/D converted and supplied to the PACS.

View Article and Find Full Text PDF

Present status of development of flat panel detectors and their clinical application in the world have been surveyed, and future trends are also explored especially in the field of material researches and methods of manufacturing. Also the importance of role of medical physicists on user side is described because characteristic physics measurement of a detector assembly is unavoidable and essential in quality assurance in clinical routine and acceptance test in hospitals. Even though physics measurements and clinical evaluations on flat panel detectors have shown remarkable progress and advances in these several years, future problems of cost down in manufacturing and quality assurance to prevent individual differences between detector assemblies must be resolved.

View Article and Find Full Text PDF

First, history of PACS in Japan from 1982 to 2002 has been investigated. By 2002 total of 1468 PACS units have been installed. Of these, 1174 are small-size PACS with less than four image display terminals, 203 are medium-size with 5-14 terminals, and 91 are large-size with 15 up to 1300 terminals.

View Article and Find Full Text PDF
Article Synopsis
  • A method was developed to prefetch medical images in a hospital's PACS by creating rules for selecting relevant examinations based on practical data.
  • The approach utilized a decision tree algorithm and was tested using extensive data from Osaka University Hospital, covering over 58,000 consultation reservations and 600,000 examination histories.
  • The results showed a selection sensitivity of around 0.8 for correctly identifying consultations where images were requested, and a specificity of about 0.7 for accurately excluding those without requests.
View Article and Find Full Text PDF
Article Synopsis
  • This study examines how the MPEG-2 compression method affects coronary angiography images, focusing on finding a high compression ratio that doesn't significantly impact the accuracy of stenosis severity assessment.
  • The research involved 44 digital cine angiographies, with three cardiologists evaluating both uncompressed and compressed images to compare results.
  • Findings indicated that a compression ratio of 80:1 had a significantly lower agreement in accuracy compared to a 40:1 ratio, establishing a foundation for future research on how image compression affects observer performance in medical imaging.
View Article and Find Full Text PDF