Biochim Biophys Acta
November 1995
Voltage-activated and spontaneous chloride-channel activity was studied in melanoma cell-line A2058 by patch-clamp technique. Whole-cell and inside-out patch recordings carried out with leak subtraction show voltage-activated chloride-conductance. In addition, a large leak-type conductance typical of epithelial cells was found in whole-cell experiments.
View Article and Find Full Text PDFThe usefulness of proton NMR spectroscopy of human blood plasma for cancer research has been extensively studied in recent years. Two main starting points have been offered by Fossel et al. (N.
View Article and Find Full Text PDFA lineshape fitting model was constructed for classifying the overlapping information in the 1H NMR spectrum of human blood plasma. A reliable assignment of the overlapping fatty acid (-CH2-)n and -CH3 resonances of the various lipoproteins (VLDL, very low density lipoprotein; LDL, low density lipoprotein; HDL high density lipoprotein) is introduced, and for the first time detailed characteristics (chemical shifts, half linewidths, and relative intensities) of the individual lipoprotein components were obtained directly from the whole plasma spectrum. This was achieved by combining the constructed lineshape fitting model and the proper 400 MHz proton NMR measurements from blood plasma of a healthy donor, from fractions of the different lipoproteins, and from plasma samples in which the lipoprotein fractions were separately added.
View Article and Find Full Text PDFThe 1H NMR spectra of the lipid region of human plasma from healthy adults, neonates, and patients with malignant and nonmalignant tumors have been recorded on a JNM-GX400 FT spectrometer operating at 399.6 MHz for protons. The chemical shifts of methylene and methyl groups of plasma lipids were measured with respect to the higher field component of the methyl proton resonance of the lactate molecule.
View Article and Find Full Text PDFStructural chromosome aberrations were analysed in the peripheral blood lymphocytes of 15 children, aged 1 to 13 years, before, immediately after, 24 hours after and 6 to 8 months after cardioangiographic examination. Statistically significant increases were only demonstrated in the frequency of gaps (p less than 0.05) and, consequently, in the frequency of aberrant cells (p less than 0.
View Article and Find Full Text PDFScand J Work Environ Health
April 1984
In an evaluation of the possible chromosome damage caused by cytostatic agents 11 nurses with long-term exposure to such agents were studied. Five laboratory workers and 11 hospital clerks served as referents. The number of chromosomally aberrant lymphocytes was significantly higher in the group of nurses than in the group of laboratory workers or hospital clerks.
View Article and Find Full Text PDFThe T1 and T2 relaxation times of pathological tissues can be different from those of normal tissues. It seems that the NMR relaxation times are of great significance in tissue characterization and tumour localization with help of NMR imaging.
View Article and Find Full Text PDFTo establish which constituents of blood influence the NMR relaxation time T1 of water protons in malignant blood diseases, 55 blood samples were studied (20 from healthy donors and 35 from patients with leukaemia, myelofibrosis and multiple myeloma). Relaxation time measurements were performed at 19.8 MHz resonance frequency and at a temperature of 33 +/- 1 degree C.
View Article and Find Full Text PDFThe CRE concept is not applicable to the assessment of the effect of combined radiotherapy when external and intracavitary radiations are given alternately and with unequal doses. Because of the numerous recurrences, we had to change our radiation treatment schemes for carcinoma cervix uteri, and we attempted, on a theoretical basis, to acquire the same biological effects as Joslin with his own method. In the comparison of different schemes we used as slightly modified approximate CRE and the "nominal dose" presented by Kellerer.
View Article and Find Full Text PDFOwing to contamination by long-lived radio-isotopes, the residual activity of an old 99Mo-99mTc generator may be large enough to prevent its disposal. The long-lived impurities of one generator were determined by energy spectrum and half-life measurements. In this generator 46Sc, 51Cr, 60 Co, 92mNb, 95Nb and 124Sb nuclides were found.
View Article and Find Full Text PDFEur J Nucl Med
August 1980
The MTFs of three different gamma camera systems have been measured using two methods. In one method a step function was used as the object and the calculations were made by means of a pocket calculator. This method has been compared with a conventional line source method, where a computer is needed in performing the calculations.
View Article and Find Full Text PDFMicrodosimetry has been a fast growing field in dosimetry during the last years. We have measured and calculated microdosimetric quantities which are important in correlation between the energy deposited in microscopic volumes and the biological effect. We have measured the energy distribution spectra in volumes with diameters of 1 and 2 mum and calculated the dose mean of specific energy and the mean event number per unit absorbed dose for the radioisotopes: 60Co, 137Cs, 99Tcm, 125J and the beta emitter 90Sr.
View Article and Find Full Text PDFMeasurements of gonad doses in intravenous urography (IVU) was performed on 47 children and in micturition cysto-urethrography (MCU) on 57 children. Ionization chamber dosimeters were placed rectally in girls and fixed on the scrotum in boys. Gonad dose ranged from 27 mrad to 201 mrad in girls and from 7 mrad to 112 mrad in boys during IVU; during MCU doses ranged from 53 mrad to 1900 mrad in girls and form 24 mrad to 309 mrad in boys.
View Article and Find Full Text PDFActa Radiol Oncol Radiat Phys Biol
March 1980
The accuracy of computerized dose planning depends essentially on the computer program. The quickest and simplest way to assess the accuracy of a commercial program is to compare the results of the computer calculations with measured values. The present report deals with the accuracy of the RADPLAN dose planning program in different situations easy to control.
View Article and Find Full Text PDFStrahlentherapie
November 1978
Nuclear magnetic relaxation times T1 and T2 of cell water protons in benign and malignant uterine cervical tissue (37 samples taken from 22 patients) were measured using a resonance frequency of 19.8 MHz. The means of relaxation times recorded for malignant tissue were (mean +/- S.
View Article and Find Full Text PDFHippuran renography indicates kidney function as reflected in a substance handled mainly by the tubules. The working conditions of the kidneys undergo a fundamental change at birth with the cessation of placenta circulation, and these organs become responsible for waste elimination. 131I-hippuran renography was performed on foetal and newborn lambs using a gamma camera and a computer.
View Article and Find Full Text PDFBasic Res Cardiol
October 1977
A simplified single-plane angiocardiographic method for the measurement of the left ventricular volumes in the reindeer heart has been developed, on the assumption that the left ventricle forms half a revolution ellipsoid. On the basis of a study of 30 ventricular casts the following formulae were constructed for the calculation of the left ventricular volume (VLV) in end-diastole (D) and end-systole (S): VLVD = 0.60 k3a2l - 3.
View Article and Find Full Text PDFOPNE HUNDRED AND SIXTY-FOUR PATIENTS WITH GYNECOLOGICAL CARCINOMAS (104 ca colli uteri, 60 cacorporis uteri) were examined retrospectively two to seven years after combined internal-external radiotherapy. Thirty-seven per cent of the patients displayed mild intestinal symptoms during the therapy. The frequency of symptoms remained unchanged after the termination of therapy, though they tended to become more severe.
View Article and Find Full Text PDFThe authors have measured proton relaxation times of gynecological cancer. T1 and T2 of human tumours are longer than proton relaxation times of corresponding normal tissues. Radiotherapy changes also proton relaxation times T1 and T2 in tissue.
View Article and Find Full Text PDF