Aims: Highly polished stems with force-closed design have shown satisfactory clinical results despite being related to relatively high early migration. It has been suggested that the minimal thickness of cement mantles surrounding the femoral stem should be 2 mm to 4 mm to avoid aseptic loosening. The line-to-line cementing technique of the femoral stem, designed to achieve stem press-fit, challenges this opinion.

View Article and Find Full Text PDF

Background: The line-to-line cementing technique is proposed to create a press-fit in the femoral canal, which is contrary to modern cementing techniques. The term 'French paradox' has been used to describe the acceptable results associated with this technique. It has been suggested that the quality of the mantle may not be satisfactory, predisposing to early failure and aseptic loosening.

View Article and Find Full Text PDF