Publications by authors named "Kirill Skovorodko"

The aim of this study was to investigate the performance of eight digital radiography systems and to optimise the dose-image quality relationship for digital pelvis radiography. The study involved eight digital radiography systems used for general examinations at Vilnius University Hospital Santaros Klinikos. An anthropomorphic pelvic phantom (CIRS, US) was used to simulate a patient undergoing clinical pelvis radiography.

View Article and Find Full Text PDF

This article presents the protocol on Quality Controls in PET/CT and PET/MRI published online in May 2022 by the European Federation of Organisations for Medical Physics (EFOMP), which was developed by the Working group for PET/CT and PET/MRI Quality Control (QC) protocol. The main objective of this protocol was to comprehensively provide simple and practical procedures that may be integrated into clinical practice to identify changes in the PET/CT/MRI system's performance and avoid short- and long-term quality deterioration. The protocol describes the quality control procedures on radionuclide calibrators, weighing scales, PET, CT and MRI systems using selected and measurable parameters that are directly linked to clinical images quality.

View Article and Find Full Text PDF

The hands of nuclear medicine (NM) personnel involved in radiopharmaceutical preparation and administration can receive significant radiation doses. The dose distribution across the hand is nonuniform and the Hp(0.07) doses obtained by an individual passive ring dosimeter do not always present a real situation.

View Article and Find Full Text PDF

The activity of prescribed radiopharmaceuticals, which are administered for diagnostic and therapeutic purposes, strongly depends on the accuracy of the measuring equipment used in nuclear medicine. This study presents the current status of uncertainty measurements of activity meters used in Lithuanian hospitals. During 2016-2021, the Ionizing Radiation Metrology Laboratory of the Center for Physical Sciences and Technology, which is the National Metrology Institute, performed a comparison of activity meters in the nuclear medicine departments of Lithuanian hospitals.

View Article and Find Full Text PDF

Purpose: The aim of this study was to measure the occupational exposure using active personal dosimeters (APD) in the PET/CT department at different stages of the operation chain i.e. radiopharmaceutical arrival, activity preparation, dispensing, injection, patient positioning, discharge and compare the radiation exposure doses received using two automatic injection/infusion systems.

View Article and Find Full Text PDF