Introduction: Emergency department (ED) patients are frequently ventilated with excessively large tidal volumes for predicted body weight based on height, which has been linked to poorer patient outcomes. We hypothesized that supplying tape measures to respiratory therapists (RT) would improve measurement of actual patient height and adherence to a lung-protective ventilation strategy in an ED-intensive care unit (ICU) environment.
Methods: On January 14, 2019, as part of a ventilator-associated pneumonia prevention bundle in our ED-based ICU, we began providing RTs with tape measures and created a best practice advisory reminding them to record patient height.