Publications by authors named "Kilian Reising"

Olecranon fractures are most frequently stabilized by tension band wiring (TBW), which unfortunately leads to relevant implant removal rates due to K-wire migration and soft tissue irritation. As lag screw osteosynthesis (LSO) might be a gentle and effective alternative in simple fracture patterns, the goal of the present study was to biomechanically compare LSO with TBW in simple olecranon fractures at a cadaver model. A simple olecranon fracture (Mayo type IIA) was created in eight pairs of human cadaver elbows, which were pairwise fixed by either TBW or two transcortical 4.

View Article and Find Full Text PDF

Background: In the treatment of unstable olecranon fractures, anatomically preshaped locking plates exhibit superior biomechanical results compared with tension band wiring. However, posterior plating (PP) still is accompanied by high rates of plate removal because of soft-tissue irritation and discomfort. Meanwhile, low-profile plates precontoured for collateral double plating (DP) are available and enable muscular soft-tissue coverage combined with angular-stable fixation.

View Article and Find Full Text PDF

Background: Biodegradable implants have gained increasing importance for the fixation of simple displaced radial head fractures to supersede implant removal and to minimize cartilage destruction. Commonly used polylactide pins still lead to higher rates of secondary loss of reduction compared with metal implants. Alternatively, implants made from a magnesium alloy meanwhile are available in a pin design that hypothetically could perform better than polylactide pins.

View Article and Find Full Text PDF

Background: Displaced fractures of the humeral capitellum are commonly treated operatively and fixed by titanium screws (TSs) either directly or indirectly. In the case of direct transcartilaginous fixation, biodegradable screws with the ability to be countersunk can be favorable regarding implant impingement and cartilage destruction. Hence, the goal of this study was to biomechanically compare headless compression screws made from titanium with a biodegradable equivalent made from a magnesium alloy.

View Article and Find Full Text PDF

For radial head osteosynthesis, biodegradable implants are gaining in importance to minimize cartilage destruction and implant impingement and to supersede implant removal. Since loss of reduction and pseudarthrosis remain challenging complications, new implants should at least provide comparable biomechanical properties as commonly used metal implants. The objective of this study was to compare the treatment by polylactide pins to titanium screws and to quantify the produced cartilage defects.

View Article and Find Full Text PDF

Background And Purpose: Unstable pelvic fractures frequently require emergency stabilization using a C-clamp or external (CC/EF) fixation. However, the effectiveness of this intervention and associated complications are still a matter of debate.

Patients And Methods: The analysis used data available from the German Pelvic Trauma Registry to study general complications, infections and mortality after primary stabilization using CC/EF in 5,499 patients (n = 957 with vs n = 4,542 without).

View Article and Find Full Text PDF

Background: Correct positioning of the cup is an important factor in total hip arthroplasty. Assessing its position from a plain anteroposterior pelvic radiograph is known to be hampered by systemic errors. This study focuses on developing a correction method to adjust for these potential sources of error and to eliminate them based on a 3D geometric analysis.

View Article and Find Full Text PDF

The aim of this study was to evaluate and compare the diagnostic accuracy, the inter-rater agreement and raters' certainty of cone beam computed tomography (CBCT) and radiography for the detection of scaphoid fractures. Our hypothesis is that the CBCT has a higher diagnostic accuracy for scaphoid fractures than radiography. We retrospectively analysed patients who underwent both radiography and CBCT examinations within 4 days to rule out a scaphoid fracture over a 2-year period in our institution.

View Article and Find Full Text PDF

Background: Fractures of the proximal humerus in patients under the age of 18 years show a low incidence; existing clinical studies only comprise small patient numbers. Different treatment methods are mentioned in the literature but a comparison of the outcome of these methods is rarely made. Up to now, no evidence-based algorithm for conservative and operative treatment is available.

View Article and Find Full Text PDF

Introduction: Many publications, mainly from other countries, suggest that the treatment of seriously injured children might be better in specialised paediatric trauma centres than in general trauma centres. Data from Germany are not available yet, but those from abroad were used for the recommendations made by the German Association for Trauma Surgery (DGU) on the topic of paediatric trauma in the "White Paper on Trauma Care". The goal of this study was to analyse whether the outcome of severely injured children is dependent on treatment level and on the availability of a paediatric surgeon based on the given data.

View Article and Find Full Text PDF

Background: Osseous healing of distal lower leg fractures can be prolonged and is often associated with wound healing problems because of the marginal soft - tissue and vascular supply in this area. Postoperative complications are frequent, and according to the literature, open reduction and plate fixation is thought to be associated with higher complication rates. The objective of this study was to evaluate the most common postoperative complications following intramedullary nailing or plate osteosynthesis of distal lower leg injuries with a focus on combined tibio-fibular fractures.

View Article and Find Full Text PDF

Background: There is little information on the pubic symphysis' normal CT appearance in children.

Objective: We sought to generate age-, gender- and maturity-related symphyseal width appearances in CT scans.

Materials And Methods: Pelvic CT scans performed for any reason during a 6-year period in patients younger than 18 years were retrospectively analyzed.

View Article and Find Full Text PDF

Background: Horizontal instability impairs clinical outcome following acute acromioclavicular joint (ACJ) reconstruction and may be caused by insufficient healing of the superior acromioclavicular ligament complex (ACLC). However, characteristics of acute ACLC injuries are poorly understood so far. Purposes of this study were to identify different ACLC tear types, assess type-specific prevalence and determine influencing cofactors.

View Article and Find Full Text PDF

Background: Several different surgical techniques are used in the treatment of olecranon fractures. Tension band wiring is one of the most preferred options by surgeons worldwide. The concept of this technique is to transform a tensile force into a compression force that adjoins two surfaces of a fractured bone.

View Article and Find Full Text PDF

Introduction: The prevalence of paediatric pelvic injury is low, yet they are often indicative of accompanying injuries, and an instable pelvis at presentation is related to long-term poor outcome. Judging diastasis of the sacroiliac joint in paediatric pelvic computed tomography is challenging, as information on their normal appearance is scarce. We therefore sought to generate age- and gender-related standard width measurements of the sacroiliac joint in children for comparison.

View Article and Find Full Text PDF

Background: Currently, closed reduction and percutaneous pinning are considered the treatment of choice for displaced supracondylar humerus fractures. However, indications exist for the use of external fixation with Schanz screws. In this in vitro study, we evaluate the biomechanical properties of a new variation for external fixation and compare them to an established construct.

View Article and Find Full Text PDF

To compare the visualization of cortical fractures, cortical defects, and orthopedic screws in a dedicated extremity flat-panel computed tomography (FPCT) scanner and a multidetector computed tomography (MDCT) scanner.We used feet of European roe deer as phantoms for cortical fractures, cortical defects, and implanted orthopedic screws. FPCT and MDCT scans were performed with equivalent dose settings.

View Article and Find Full Text PDF

Introduction: Prospective collected data of the TraumaRegister DGU(®) were analyzed to derive survival rates and predictors for non-survival in the children who had suffered traumatic cardiorespiratory arrest. Different time points of resuscitation efforts (only preclinical, in the emergency room (ER) or preclinical+ER) were analyzed in terms of mortality and neurological outcome.

Methods: The database of the TraumaRegister DGU(®) comprising 122,742 patients from 1993 to 2013 was analyzed.

View Article and Find Full Text PDF

Background: Closed reduction and percutaneous pinning is regarded as the treatment of choice for unstable supracondylar humerus fractures, but there are cases in which the use of external fixation is preferable.

Objective: The aim of this study was to investigate whether the method of external fixation could be considered as a stable alternative to percutaneous pinning and whether there was a difference in stability between two different external fixator constructs.

Methods: Eighteen synthetic humeri were allocated to three groups of six bones each.

View Article and Find Full Text PDF

Unlabelled: For the treatment of distal humerus an approach involving olecranon osteotomy is frequently preferred as it offers a clearer view, especially in cases of complex intraarticular fractures. It is however associated with the high risk of osteotomy-related complications such as nonunion, delayed healing, implant failure and migration of wires. The aim of the present study was to evaluate the stability of different new procedures that stabilize olecranon osteotomy compared with conventional tension band wiring.

View Article and Find Full Text PDF

Purpose: Our aim was to explore the effect of varying in vitro culture conditions on general chondrogenesis of minced cartilage (MC) fragments.

Methods: Minced, fibrin-associated, bovine articular cartilage fragments were cultured in vitro within polyurethane scaffold rings. Constructs were maintained either free swelling for two or four weeks (control), underwent direct mechanical knee-joint-specific bioreactor-induced dynamic compression and shear, or they were maintained free swelling for two weeks followed by two weeks of bioreactor stimulation.

View Article and Find Full Text PDF

Purpose: Aim of the study was the analysis of cytokine expression in ankle osteoarthritis (OA) hypothesizing age-dependent regulation patterns.

Methods: Forty-nine patients undergoing an arthroscopy of the ankle with different stages of chronic OA were prospectively included in a clinical trial comparing the group <18 years (n = 9, Ø15.1 ± 2.

View Article and Find Full Text PDF

Rationale And Objectives: The aim of this study was to evaluate if a dose-reduced, dose-neutral dual-energy computed tomographic (CT) virtual noncalcium technique can equally detect posttraumatic bone marrow lesions (BMLs) of the knee.

Materials And Methods: Fifty patients underwent DE CT imaging with either a standard dose (group A) or a dose equal to that of a single-energy CT scan (group B) (28% dose reduction) and magnetic resonance imaging for knee trauma workup. Calcium was virtually subtracted from the images.

View Article and Find Full Text PDF

In total hip replacement, patient placement in the lateral position is preferred by many surgeons. However, it complicates registration of the so-called pelvic coordinate system that is the standard reference for surgeons to measure cup orientation. This coordinate system comprises the anterior pelvic plane and the mid-sagittal plane, and it is conventionally registered on the basis of bony anatomical landmarks including the left and the right anterior superior iliac spine (ASIS).

View Article and Find Full Text PDF