The aim of this study was to examine the settling of abutments into implants and the removal torque value under static loading. Five different implant-abutment connections were selected (Ext: external butt joint + two-piece abutment; Int-H2: internal hexagon + two-piece abutment; Int-H1: internal hexagon + one-piece abutment; Int-O2: internal octagon + two-piece abutment; Int-O1: internal octagon + one-piece abutment). Ten implant-abutment assemblies were loaded vertically downward with a 700 N load cell at a displacement rate of 1 mm/min in a universal testing machine.
View Article and Find Full Text PDFPurpose: With surgical modifications reflecting plate design differences of the specific rigid locking plate adding a metal wedge, uniplane high tibial osteotomy (HTO) has fewer lateral-hinge fractures and fewer plate irritations than biplane HTO.
Methods: Uniplane HTO with a rigid locking plate adding a metal wedge was compared with biplane HTO with a rigid locking plate including a proximal D-hole. For comparison, the HTO patients' medical records and radiological results in a single institution were retrospectively reviewed.
Purpose: High fibular osteotomy (HFO) is a simple surgical technique to reduce pain and improve function in patients with osteoarthritis via fibular osteotomy. We report short-term results of HFO and mesenchymal cell induced chondrogenesis (MCIC) for the treatment of osteoarthritis of knee with varus deformity.
Patients And Methods: 45 symptomatic patients with 14 males and 31 females age ranging from 40 to 75 years were treated by HFO and MCIC.
Purpose: The purpose of this review is to compare the clinical and radiological outcomes between open and closed wedge distal femoral varus osteotomy (DFO).
Methods: A literature search of online databases (MEDLINE, EMBASE, and Cochrane Library database) was made in addition to manual search of major orthopedic journals. Data were searched from the time period of January 1990 to October 2016.
This study describes the pharmacodynamic interaction between propofol and remifentanil. Sixty patients who were scheduled for elective surgery under general anaesthesia (30 males/30 females) were enrolled. Patients were randomly allocated to receive one of 15 combinations of drug levels.
View Article and Find Full Text PDFThe role of atypical bacteria and the effect of antibiotic treatments in acute bronchitis are still not clear. This study was conducted at 22 hospitals (17 primary care clinics and 5 university hospitals) in Korea. Outpatients (aged ≥ 18 yr) who had an acute illness with a new cough and sputum (≤ 30 days) were enrolled in 2013.
View Article and Find Full Text PDFPurpose: The aim of this study was to evaluate and compare the settling of abutments into implants and the removal torque values (RTVs) before and after cyclic loading.
Materials And Methods: Five different implant-abutment connections were tested: Ext = external butt joint + two-piece abutment; Int-H2 = internal hexagon + two-piece abutment; Int-H1 = internal hexagon + one-piece abutment; Int-O2 = internal octagon + two-piece abutment; and Int-O1 = internal octagon + one-piece abutment. Ten abutments from each group were secured to their corresponding implants (total n = 50).
Knee Surg Sports Traumatol Arthrosc
October 2013
Purpose: A comparison has been made between navigation-assisted and conventional measured resection total knee arthroplasty (TKA), under the hypothesis that navigation assistance would improve the precision and consistency of component alignment and femoral component rotation.
Methods: The following radiographic parameters were measured: mechanical femorotibial angle, coronal and sagittal component angle, and femoral component rotation. Femoral condylar lift-off was checked by axial radiographs, and thresholds for outliers were set at 1.
Primary mycobacterial infections in the musculoskeletal system are rare with a limited number of published case reports. This report describes a case involving a primary musculoskeletal tuberculous abscess. A 62-year-old male patient who had a right total hip arthroplasty performed 8 years earlier, using metal-on-metal articulation presented with a 1-year history of non-tender masses on his right thigh.
View Article and Find Full Text PDFAim: Settling (embedment relaxation), which is the main cause for screw loosening, is developed by microroughness between implant and abutment metal surface. The objective of this study was to evaluate and compare the relationship between the level of applied torque and the settling of abutments into implants in external and internal implant-abutment connection.
Material And Methods: Five different implant-abutment connections were used (Ext, External butt joint + two-piece abutment; Int-H2, Internal hexagon + two-piece abutment; Int-H1, Internal hexagon + one-piece abutment; Int-O2, Internal octagon + two-piece abutment; Int-O1, Internal octagon + one-piece abutment).
Background/aims: Obesity is associated with the risk of colorectal cancer. However, there is a lack of information about the relationship between obesity and colorectal adenoma. We investigated whether general and abdominal obesity are risk factors for colorectal adenoma.
View Article and Find Full Text PDFThe Pd-catalyzed reaction of unsymmetrical alkynes with organoboronic acids gave a mixture of products and, whose ratios were controlled by the electronic as well as steric effects of the substrates.
View Article and Find Full Text PDFAngew Chem Int Ed Engl
February 2003