Publications by authors named "Khoa D Tran"

A simple grinding method using polyvinylpyrrolidone (PVP) as a capping agent is introduced to synthesize CoFeO nanoparticles. The effects of calcination temperature (ranging from 450 to 850 °C) on the structural, morphological, physical, and optical properties of the materials are investigated using various techniques, including thermogravimetric analysis/differential scanning calorimetry (TGA/DSC), powder X-ray diffraction (PXRD), transmission electron microscopy (TEM), N adsorption isotherm, ultraviolet-visible diffuse reflectance spectroscopy (UV-vis DRS), and vibrating sample magnetometry (VSM). The presence of PVP significantly suppresses the agglomeration of the materials, resulting in a nanocrystalline size of 18 nm for a sample calcined at 650 °C, which is approximately 38% smaller than that of the sample synthesized without PVP.

View Article and Find Full Text PDF

Background: The debate continues among craniofacial surgeons regarding the effectiveness of strip craniectomy (SC) compared with cranial vault remodeling (CVR) in achieving optimal functional and aesthetic outcomes in patients with single-suture craniosynostosis. This study aimed to compare long-term patient-reported outcomes (PROs) between SC and CVR procedures at a single institution using the validated FACE-Q Craniofacial module.

Methods: Patients older than or equal to 8 years of age and parents of patients younger than 8 years of age who underwent SC or CVR for single-suture craniosynostosis were eligible.

View Article and Find Full Text PDF
Article Synopsis
  • Moebius syndrome (MoS) is a rare condition that affects facial movement and causes problems with closing the eyelids, making it hard for people to fully blink.
  • A study was done with 15 people at a conference to learn about their experiences living with this condition, and they discussed how it affects their daily lives and how society sees them.
  • The researchers noted that many participants felt a mix of challenges, like social stigma, and had different opinions on surgery, but many also showed a strong sense of self-acceptance about their situation.
View Article and Find Full Text PDF

Purpose: We evaluate the quality and feasibility of preloading Descemet stripping automated endothelial keratoplasty (DSAEK) grafts into a modified EndoGlide Ultrathin system for graft injection.

Methods: DSAEK grafts were prepared by experienced processing technicians at 2 separate locations, loaded into a modified EndoGlide Ultrathin, and placed in storage media. Grafts processed at one location were shipped cross-country overnight to the other location and were examined on arrival for positioning within the modified EndoGlide Ultrathin.

View Article and Find Full Text PDF

Purpose: To evaluate the efficacy and safety of sterile corneal allograft ring segments implantation for the treatment of keratoconus by analyzing long-term visual, refractive, and tomographic clinical outcomes.

Methods: This prospective study included 62 eyes of 49 patients with keratoconus who underwent corneal allograft ring segments implantation at Istanbul Medipol University Faculty of Medicine between February 2020 and August 2022. Surgical outcomes using the Istanbul nomogram were evaluated in patients preoperatively and postoperatively at 1 month, 6 months, 1 year, and 3 years.

View Article and Find Full Text PDF

High-performance production of green hydrogen gas is necessary to develop renewable energy generation technology and to safeguard the living environment. This study reports a controllable engineering approach to tailor the structure of nickel-layered double hydroxides via doped and absorbed platinum single atoms (Pt) promoted by low electronegative transition metal (Mn, Fe) moieties (Pt-Mn,Fe-Ni LDHs). We explore that the electron donation from neighboring transition metal moieties results in the well-adjusted -band center with the low valence states of Pt and Pt, thus optimizing adsorption energy to effectively accelerate the H release.

View Article and Find Full Text PDF

In this study, twenty-five yeast strains were isolated from soil samples collected in the gold mining ore in Gia Lai, Vietnam. Among them, one isolate named GL1 could highly tolerate Cu up to 10 mM, and the isolates could also grow in a wide range of pH (3-7), and temperature (10-40 °C). Dried biomass of GL1 was able to remove Cu effectively up to 90.

View Article and Find Full Text PDF

Purpose: The aim of this study was to examine endothelial cell loss (ECL) associated with preloaded Descemet stripping automated endothelial keratoplasty (DSAEK) grafts loaded into 3 carriers of different size and shape.

Methods: Thirty-six donor corneas were prepared for DSAEK and loaded into an EndoGlide Ultrathin (control) (2.0 mm × 3.

View Article and Find Full Text PDF

Purpose: The aim of this study was to compare the performance of Kerasave and Optisol-GS for hypothermic corneal storage for 14 days.

Methods: This study was a prospective laboratory investigation. Mate corneas were recovered into Kerasave or Optisol-GS (27 pairs) and stored at 2°C to 8°C for 14 days.

View Article and Find Full Text PDF

Purpose: To evaluate the clinical feasibility and visual outcomes of allograft corneal ring segment implantation for the treatment of keratoconus.

Methods: This case series, included forty-four eyes of 32 patients with a 6-month follow-up. All cases were treated according to the Istanbul nomogram.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to determine whether manipulation of preloaded single-scroll Descemet membrane endothelial keratoplasty (DMEK) grafts within the fluid column of an injector can safely and reliably result in formation of double-scroll DMEK grafts and whether there are differential effects on younger versus older donor tissue.

Methods: Pairs of DMEK grafts prepared from older (65-80 years) and younger (48-64 years) donors were preloaded into a Straiko modified Jones tube. One member of the pair was manipulated within the fluid column to form a double-scroll graft, and the other remained unmanipulated.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to determine whether controlled balanced salt solution (BSS) bursts during graft preparation can safely promote formation of a double-scrolled Descemet membrane endothelial keratoplasty (DMEK) graft in younger donor tissue.

Methods: DMEK grafts prepared from young donor tissue (average age, 55 years; range, 39-66 years) were floated in BSS to spontaneously form scrolls (N = 10 pairs). Controlled BSS bursts were used to promote double-scroll (DS) formation in 1 member of each pair.

View Article and Find Full Text PDF

Purpose: The aim of this study was to determine whether loading a Descemet membrane endothelial keratoplasty (DMEK) graft using a drop-in procedure results in more endothelial cell loss (ECL) than the standard suction procedure.

Methods: Pairs of donor corneas with equivalent preprocessing endothelium were prepared using the standard protocol of our eye bank. One member of each pair was loaded into an injector using the standard suction protocol.

View Article and Find Full Text PDF

Purpose: To ascertain whether death-to-preservation time (DPT) is associated with donor endothelial cell density (ECD), primary graft failure (PGF), and infection.

Methods: Donor corneas aged older than 10 years with ECD 2000 to 4500 cells/mm2 were procured between 2011 and 2018 by a single eye bank. Donor corneas were analyzed retrospectively for the main outcome measures of PGF, infection, and ECD.

View Article and Find Full Text PDF

Purpose: To evaluate the effects of electron-beam (E-beam) irradiation on the human cornea and the potential for E-beam sterilization of Boston keratoprosthesis (BK) devices when pre-assembled with a donor cornea prior to sterilization.

Methods: Human donor corneas and corneas pre-assembled in BK devices were immersed in recombinant human serum albumin (rHSA) media and E-beam irradiated at 25 kGy. Mechanical (tensile strength and modulus, and compression modulus), chemical, optical, structural, and degradation properties of the corneal tissue after irradiation and after 6 months of preservation were evaluated.

View Article and Find Full Text PDF

Electron beam (E-beam) irradiation is an attractive and efficient method for sterilizing clinically implantable medical devices made of natural and/or synthetic materials such as poly(methyl methacrylate) (PMMA). As ionizing irradiation can affect the physicochemical properties of PMMA, understanding the consequences of E-beam sterilization on the intrinsic properties of PMMA is vital for clinical implementation. A detailed assessment of the chemical, optical, mechanical, morphological, and biological properties of medical-grade PMMA after E-beam sterilization at 25 and 50 kiloGray (kGy) is reported.

View Article and Find Full Text PDF

Purpose: To investigate stamp visibility and endothelial cell loss (ECL) after the application of an orientation mark to Descemet membrane endothelial keratoplasty (DMEK) grafts supported by an air bubble.

Methods: Eighteen DMEK grafts were prepared at an eye bank using a technique where an orientation mark was applied to the stromal surface of a DMEK graft that was supported by a small air bubble placed at the edge of the 2 endothelial surfaces of the graft. Grafts were evaluated at 2 and 5 days for stamp visibility and at 5 days with calcein-AM staining for ECL.

View Article and Find Full Text PDF

Purpose: To examine tissue loss rates, processing time, and primary graft failure (PGF) of "prestripped-only" Descemet membrane endothelial keratoplasty (DMEK) grafts at a single eye bank and how these parameters changed after the introduction of steps to preload tissue among experienced processors.

Methods: Tissue loss and processing time during DMEK graft preparation as well as PGF were analyzed retrospectively at a single eye bank between 2012 and 2018. Outcomes were assessed in consecutive grafts before and after the introduction of preloading to the eye bank's standard operating procedure.

View Article and Find Full Text PDF

Previous studies in have identified the cytoskeletal protein KHARON as being important for both flagellar trafficking of the glucose transporter GT1 and for successful cytokinesis and survival of infectious amastigote forms inside mammalian macrophages. KHARON is located in three distinct regions of the cytoskeleton: the base of the flagellum, the subpellicular microtubules, and the mitotic spindle. To deconvolve the different functions for KHARON, we have identified two partner proteins, KHAP1 and KHAP2, which associate with KHARON.

View Article and Find Full Text PDF

Purpose: To determine whether specific donor characteristics influence postoperative rebubble rate and 6-month endothelial cell loss (ECL) in Descemet membrane endothelial keratoplasty (DMEK).

Methods: A retrospective analysis of a consecutive series of 857 DMEK surgeries using eye bank-prepared donor tissue was performed between September 2013 and April 2018. DMEK graft characteristics including donor age, preoperative endothelial cell density (ECD), preservation time, death-to-preservation time, and donor diabetes status were analyzed for correlation with rebubble rate and 6-month postoperative ECL.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to evaluate how effective frozen amphotericin B is against the fungus Candida albicans when added to the eye preservation solution Optisol-GS.
  • Triplicate samples of Optisol-GS were inoculated with 10 colony-forming units of the fungus and supplemented with either freshly resuspended amphotericin B or that frozen for varying durations.
  • Results showed minimal differences in antifungal efficacy between freshly resuspended and overnight frozen amphotericin B, but the frozen for 4 weeks variant was still effective, achieving over 90% reduction in fungal growth within 6 hours and over 99% after 72 hours.
View Article and Find Full Text PDF

Purpose: To ascertain whether offsetting the Descemet membrane endothelial keratoplasty (DMEK) punch can expand the donor pool in conjunction with prepunched and preloaded services by recapturing the corneas otherwise excluded by the conventional central clear zone criteria.

Methods: In this retrospective review of corneas recovered and processed for DMEK by a single eye bank between March 2017 and October 2018, corneas failing to meet the conventional central clear zone requirement during initial evaluation (defined as an area in the central cornea where an 7.5- to 8.

View Article and Find Full Text PDF

Purpose: To examine barriers and facilitators to adoption of Descemet membrane endothelial keratoplasty (DMEK) for treatment of endothelial dysfunction.

Methods: Anonymous electronic surveys were emailed to surgeons ordering corneal transplant tissue in the past 18 months from 2 eye banks in the United States (US).

Results: Of 365 surgeons emailed, 118 (32%) completed the survey.

View Article and Find Full Text PDF

Purpose: To determine the concentration of amphotericin B that would be both effective against Candida albicans contamination and safe for corneal endothelial cells (CECs) in cold storage conditions.

Methods: Triplicate media cultures were inoculated with 10 colony-forming units (CFUs)/mL of C. albicans (American Type Culture Collection 10231), supplemented with amphotericin B (0-20 μg/mL), stored in cold conditions (2°C-8°C) for 72 hours, and analyzed quantitatively for CFUs.

View Article and Find Full Text PDF