Publications by authors named "Kevin Wolfe"

Background: The Organ Care System (OCS) (Transmedics, Andover, MA) reduces cold ischemic time of donor hearts by producing a normothermic beating state during ex vivo perfusion, enabling extended ex situ intervals, which potentially increases donor pool. We aimed to compare outcomes in utilization of OCS and conventional cold storage technique.

Methods: Consecutive heart transplants following brain death at our institution between May 2022 and July 2023 were analyzed.

View Article and Find Full Text PDF

Key Points: Simultaneous heart–kidney transplant is associated with high rates of kidney graft failure which are worse when compared with kidney transplant alone. The major causes of kidney graft failure in simultaneous heart–kidney transplant recipients were patient death and primary nonfunction of kidney graft.

Background: The indications and outcomes of simultaneous heart–kidney transplantation (SHKT) remain suboptimally defined.

View Article and Find Full Text PDF

Calcific aortic valve disease (CAVD) is a debilitating condition for which there are limited therapeutic options aside from valve replacement. As such, it is crucial to explore alternative management strategies for CAVD. Non-steroidal anti-inflammatory drugs (NSAIDs), particularly celecoxib, have been the subject of debate in the literature regarding their potential impact on CAVD.

View Article and Find Full Text PDF

Unlabelled: Scarcity of donor hearts continues to be a challenge for heart transplantation (HT). The recently Food and Drug Administration-approved Organ Care System (OCS; Heart, TransMedics) for ex vivo organ perfusion enables extension of ex situ intervals and thus may expand the donor pool. Because postapproval real-world outcomes of OCS in HT are lacking, we report our initial experience.

View Article and Find Full Text PDF

Background: In heart transplantation (HT), peripheral veno-arterial extracorporeal membranous oxygenation (VA-ECMO) is utilized preoperatively as a direct bridge to HT or postoperatively for primary graft dysfunction (PGD). Little is known about wound complications of an arterial VA-ECMO cannulation site which can be fatal.

Methods: From 2009 to 2021, outcomes of 80 HT recipients who were supported with peripheral VA-ECMO either preoperatively or postoperatively were compared based on the site of arterial cannulation: axillary (AX: N = 49) versus femoral artery (FA: N = 31).

View Article and Find Full Text PDF

Retinal prosthetic devices can significantly and positively impact the ability of visually challenged individuals to live a more independent life. We describe a visual processing system which leverages image analysis techniques to produce visual patterns and allows the user to more effectively perceive their environment. These patterns are used to stimulate a retinal prosthesis to allow self guidance and a higher degree of autonomy for the affected individual.

View Article and Find Full Text PDF

Wide complex tachycardia is not uncommon in patients with underlying structural heart disease and reduced ejection fraction. It is important to make the correct diagnosis as it carries prognostic and clinical implications. We present a case of a challenging wide complex rhythm detected on remote telemetry monitoring.

View Article and Find Full Text PDF

Background: Craniomaxillofacial reconstruction with patient-specific, customized craniofacial implants (CCIs) is ideal for skeletal defects involving areas of aesthetic concern-the non-weight-bearing facial skeleton, temporal skull, and/or frontal-forehead region. Results to date are superior to a variety of "off-the-shelf" materials, but require a protocol computed tomography scan and preexisting defect for computer-assisted design/computer-assisted manufacturing of the CCI. The authors developed a craniomaxillofacial surgical assistance workstation to address these challenges and intraoperatively guide CCI modification for an unknown defect size/shape.

View Article and Find Full Text PDF

Cranioplasty treats and repairs cranial defects with a custom craniofacial implant (CCI). Typically, surgeons know the defect size prior to surgery. Recent efforts consider single-stage cranioplasty-performing the bony resection and fixating the CCI in a single operation.

View Article and Find Full Text PDF

Snake-like manipulators with a large, open lumen can offer improved treatment alternatives for minimally-and less-invasive surgeries. In these procedures, surgeons use the manipulator to introduce and control flexible tools in the surgical environment. This paper describes a predictive algorithm for estimating manipulator configuration given tip position for nonconstant curvature, cable-driven manipulators using energy minimization.

View Article and Find Full Text PDF

Background: A unique form of lead failure has been described in the Riata (8-F) and Riata ST (7-F) silicone defibrillation lead degradation of the outer insulation, resulting in the externalization of conductor cables.

Objective: To assess rates of lead revision due to lead failure in Riata leads affected by the Riata advisory.

Methods: Nineteen implantable cardioverter-defibrillator implant and follow-up centers were surveyed.

View Article and Find Full Text PDF

Several different mechanical models of double-helical nucleic-acid structures that have been presented in the literature are reviewed here together with a new analysis method that provides a reconciliation between these disparate models. In all cases, terminology and basic results from the theory of Lie groups are used to describe rigid-body motions in a coordinate-free way, and when necessary, coordinates are introduced in a way in which simple equations result. We consider double-helical DNAs and RNAs which, in their unstressed referential state, have backbones that are either straight, slightly precurved, or bent by the action of a protein or other bound molecule.

View Article and Find Full Text PDF

Background: It has been observed that replacement of an implantable cardioverter-defibrillator generator in response to a device advisory may be associated with a substantial rate of complications, including death. The risk of lead revision in response to a lead advisory has not been determined previously.

Methods And Results: Twenty-five implantable cardioverter-defibrillator implantation and follow-up centers from the Canadian Heart Rhythm Society Device Advisory Committee were surveyed to assess complication rates as a result of lead revisions due to the Sprint Fidelis advisory issued in October 2007.

View Article and Find Full Text PDF

The Canadian Heart Rhythm Society (CHRS) Device Advisory Committee was commissioned to respond to advisories regarding cardiac rhythm device and lead performance on behalf of the CHRS. In the event of an advisory, the Chair uses an e-mail network to disseminate advisory information to Committee members broadly representative of the Canadian device community. A consensus recommendation is prepared by the Committee and made available to all Canadian centres on the CHRS Web site after approval by the CHRS executive.

View Article and Find Full Text PDF

Many surgeons continue to actively pursue surgical approaches that are less invasive for their patients. This pursuit requires the surgeon to adapt to new instruments, techniques, technologies, knowledge bases, visual perspectives, and motor skills, among other changes. The premise of this paper is that surgeons adopting minimally invasive approaches are particularly obligated to maintain an accurate perception of their own competencies and learning needs in these areas (ie, self-efficacy).

View Article and Find Full Text PDF

Background/objective: The Canadian Heart Rhythm Society (CHRS) Device Advisory Committee was commissioned in 2006 to develop a mechanism for responding to advisories regarding cardiac rhythm device and lead performance.

Methods: In the event of an advisory, the Chair classifies the advisory as urgent, semi-urgent, or routine based on the nature of the threat to the patient and the number of patients affected. The Chair uses an e-mail network with the committee members to disseminate advisory information and to assemble a consensus recommendation.

View Article and Find Full Text PDF

Purpose: Pulmonary dysfunction commonly occurs following coronary artery bypass graft (CABG) surgery, increasing morbidity and mortality. We hypothesized that thoracic epidural anesthesia (TEA) would improve pulmonary function and would decrease complications in patients undergoing CABG surgery.

Methods: This prospective, randomized, controlled trial was conducted with Ethics Board approval.

View Article and Find Full Text PDF

Background: The Medtronic Sprint Fidelis family of leads has recently been the subject of a widespread advisory. Lead failure rates are estimated at 2.3% at 30 months, 2.

View Article and Find Full Text PDF

Atrial fibrillation (AF) is common during the course of acute myocardial infarction and is associated with left atrial (LA) dilatation. However, the role of LA depolarization abnormality on the electrocardiogram (ECG) in the setting of LA dilatation was not studied in this context. Patients admitted with non-ST-segment elevation myocardial infarction (NSTEMI) who developed new-onset AF (International Classification of Diseases, Ninth Revision code 427.

View Article and Find Full Text PDF