The Canadian Organization of Medical Physicists (COMP), in close partnership with the Canadian Partnership for Quality Radiotherapy (CPQR) has developed a series of Technical Quality Control (TQC) guidelines for radiation treatment equipment. These guidelines outline the performance objectives that equipment should meet in order to ensure an acceptable level of radiation treatment quality. The TQC guidelines have been rigorously reviewed and field tested in a variety of Canadian radiation treatment facilities.
View Article and Find Full Text PDFIn external beam radiation therapy (EBRT), skin dose measurement is important to evaluate dose coverage of superficial target volumes. Treatment planning systems (TPSs) are often inaccurate in this region of the patient, so in vivo measurements are necessary for skin surface dose estimation. In this work, superficial dose distributions were measured using radiochromic translucent poly(vinyl alcohol) cryogels.
View Article and Find Full Text PDFChest wall radiation therapy treatment delivery was monitored using a 5 mm thick radiochromic poly(vinyl alcohol) cryogel that also provided buildup material. The cryogels were used to detect positioning errors and measure the impact of shifts for a chest wall treatment that was delivered to a RANDO phantom. The phantom was shifted by ± 2, ± 3, and ± 5 mm from the planned position in the anterior/posterior (A/P) direction; these shifts represent setup errors and the uncertainty associated with lung filling during breath-hold.
View Article and Find Full Text PDFHigh-grade dysplasia (HGD) in Barrett’s esophagus (BE) poses increased risk for developing esophageal adenocarcinoma. To date, early detection and treatment of HGD regions are still challenging due to the sampling error from tissue biopsy and relocation error during the treatment after histopathological analysis. In this study, CP-A (metaplasia) and CP-B (HGD) cell lines were used to investigate the “seek-and-treat” potential using 5-aminolevulinic acid-induced protoporphyrin IX (PpIX).
View Article and Find Full Text PDFA stable cryogel dosimeter was prepared using ferrous benzoic xylenol orange (FBX) in a transparent poly-(vinyl alcohol) (PVA) cryogel matrix. Dose response was evaluated for different numbers of freeze-thaw cycles (FTCs), different concentrations of PVA, and ratios of water/dimethyl sulfoxide. Linear relationships between dose and absorbance were obtained in the range of 0-1000 cGy for all formulations.
View Article and Find Full Text PDFPhotodynamic Therapy (PDT) provides an opportunity for treatment of various invasive tumors by the use of a cancer targeting photosensitizing agent and light of specific wavelengths. However, real-time monitoring of drug localization is desirable because the induction of the phototoxic effect relies on interplay between the dosage of localized drug and light. Fluorescence emission in PDT may be used to monitor the uptake process but fluorescence intensity is subject to variability due to scattering and absorption; the addition of fluorescence lifetime may be beneficial to probe site-specific drug-molecular interactions and cell damage.
View Article and Find Full Text PDFThe time-resolved fluorescence of photosensitizers (PSs) of varying hydrophobicities, di-and tetrasulfonated Al phthalocyanines (Al-2 and Al-4), and Photochlor (HPPH), was investigated in liposomes used as cell-mimetic models. Using frequency-and time-domain apparatus, the fluorescence lifetime, tau(fluo), was compared for PSs free in aqueous solution and in a liposome-associated state at varied temperatures (25 to 78 degrees C) and oxygen concentrations (0-190 microM). The analysis of tau(fluo) revealed different decay behaviors for the free-solution and liposome-confined PSs, most significantly for the lipophilic HPPH.
View Article and Find Full Text PDFThe effect of photodynamic therapy treatments depends on the concentration of photosensitizer at the treatment site; thus a simple method to quantify concentration is desirable. This study compares the concentration of a fluorophore and sensitizer, aluminum phthalocyanine tetrasulfonate (AlPcS4), measured by two simple fluorescence-based techniques in vivo to post mortem chemical extraction and fluorometric assay of those tissues: skin, muscle, fascia, liver, and kidney (cortex and medulla). Fluorescence was excited and detected by a single optical fiber, or by an instrument that measured the ratio of the fluorescence and excitation reflectance.
View Article and Find Full Text PDFSteady-state diffusion theory models of fluorescence in tissue have been investigated for recovering fluorophore concentrations and fluorescence quantum yield. Spatially resolved fluorescence, excitation and emission reflectance Carlo simulations, and measured using a multi-fibre probe on tissue-simulating phantoms containing either aluminium phthalocyanine tetrasulfonate (AlPcS4), Photofrin meso-tetra-(4-sulfonatophenyl)-porphine dihydrochloride The accuracy of the fluorophore concentration and fluorescence quantum yield recovered by three different models of spatially resolved fluorescence were compared. The models were based on: (a) weighted difference of the excitation and emission reflectance, (b) fluorescence due to a point excitation source or (c) fluorescence due to a pencil beam excitation source.
View Article and Find Full Text PDFQuantifying fluorescent compounds in turbid media such as tissue is made difficult by the effects of multiple scattering and absorption of the excitation and emission light. The approach that we used was to measure fluorescence using a single 200-microm optical fiber as both the illumination source and the detector. Fluorescence of aluminum phthalocyanine tetrasulfonate (AlPcS4) was measured over a wide range of fluorophore concentrations and optical properties in tissue-simulating phantoms.
View Article and Find Full Text PDF