Publications by authors named "Kevin Gillmann"

Prcis: In this retrospective study, nonpenetrating deep sclerectomy (NPDS) and penetrating deep sclerectomy (PDS) interventions showed similar >90% complete success rates at 1-year postsurgery. However, NPDS achieved a superior safety profile in terms of best-corrected visual acuity (BCVA) recovery and rates of post-surgical complications.

Objective: Comparing the surgical outcomes of 2 surgical techniques: NPDS and PDS.

View Article and Find Full Text PDF
Article Synopsis
  • The study analyzes the long-term effects of iStent technologies on glaucoma progression, focusing on visual field changes and intraocular pressure (IOP) reduction.
  • Out of fifteen identified studies involving 1115 eyes, the implantation of iStent devices led to an average IOP reduction of 26.6% over a follow-up period of nearly 38 months.
  • The findings indicate that the mean rate of visual field progression for patients using iStent was -0.024 dBs/year, comparable to healthy eyes and less than progression rates in those treated with medication for glaucoma.
View Article and Find Full Text PDF

Purpose: Measuring and controlling intraocular pressure (IOP) provide the foundation for glaucoma treatment. Self-tonometry has been proposed as an alternative to measure IOP throughout the entire day better. The novel EYEMATE-SC sensor (Implandata) is implanted in the suprachoroidal space to enable contactless continual IOP monitoring.

View Article and Find Full Text PDF

Background: The purpose of this study is to evaluate the outcome of deep sclerectomy (DS) as a secondary procedure following failed ab-interno XEN gel stent implantation in patients with open-angle glaucoma. Methods: Prospective, single-center, non-randomized, interventional study. Consecutive eyes that underwent mitomycin C (MMC) augmented XEN gel stent surgery, with uncontrolled intraocular pressure (IOP) or signs of disease progression, were included to undergo MMC-augmented DS.

View Article and Find Full Text PDF

Objectives: To describe the efficacy and safety of goniotomy with trabecular meshwork excision using the Kahook Dual Blade (KDB, New World Medical Inc., Rancho Cucamonga, CA) in patients with severe or refractory glaucoma.

Methods: This retrospective multicentre case series reports on 40 eyes with severe or refractory open-angle glaucoma that underwent standalone or combined KDB goniotomy and were followed for 12 months post-operatively in the United-States, Mexico and Switzerland.

View Article and Find Full Text PDF

Purpose: In response to the spread of COVID-19 in Switzerland, ophthalmology practices implemented a variety of preventive measures in order to minimise the risk of contamination to their patients and staff. Yet, some studies suggested that over a quarter of all glaucoma patients never returned to the clinic after the first lockdown eased. This raises the question of the factors influencing Patients' likelihood to keep their appointments in this COVID-19 era.

View Article and Find Full Text PDF

Purpose: To evaluate long-term intraocular temperature (IOT) variations in eyes with primary open-angle glaucoma (POAG) using an intraocular telemetric sensor.

Methods: This prospective, open-label, multicentre observational study analysed the IOT variations in 22 eyes of 22 patients with POAG. All enrolled patients underwent implantation of an intraocular pressure (IOP) sensor during cataract surgery.

View Article and Find Full Text PDF

Aim And Background: The present case report describes a novel surgical technique combining XEN gel stent implantation and deep sclerectomy: XEN-augmented deep sclerectomy (XEN-DS).

Case Description: An active 96-year-old Caucasian woman suffering from pseudoexfoliative glaucoma (PEXG) presented with intraocular pressure (IOP) of 24 mm Hg and a double arcuate visual field defect [mean deviation (MD) -9.6 dB] in her only functional eye despite maximal medical therapy.

View Article and Find Full Text PDF

Background/aim: The aim of this study was to assess the difference in outcome between the first-operated and the second-operated eyes after nonpenetrating deep sclerectomy (DS), and to identify potential success predictors for the second eye.

Methods: This single-surgeon, retrospective study analyzed the outcomes of all bilateral nonsimultaneous DS with at least 24 months of follow-up. Its main outcome measure was surgical success, defined as unmedicated intraocular pressure (IOP) ≤15 mm Hg associated with a relative reduction ≥20%.

View Article and Find Full Text PDF

Purpose: The aim of this study was to analyse the safety profile and efficacy of ab interno viscocanaloplasty (ABiC) through to 12 months post-operatively.

Methods: In this retrospective study, the medical records of all patients who underwent ABiC between September 2015 and December 2019 were analysed. Complete success was defined as a 12-month reduction in intraocular pressure (IOP) ≥ 20% from baseline with no concomitant medications.

View Article and Find Full Text PDF

Purpose: Intravitreal injections (IVIs) may create transient intraocular pressure (IOP) elevation. This report describes continuous IOP fluctuations following multiple IVI measured with a permanent implantable sensor.

Patients And Methods: We report the case of a 49-year-old white glaucomatous male with refractory macular edema secondary to central retinal vein occlusion in his left eye who underwent deep sclerectomy combined with the implantation of a suprachoroidal tonometry sensor.

View Article and Find Full Text PDF

The recent advent of continuous intraocular pressure (IOP) telemetry has led to an increased awareness of the importance of IOP fluctuations, and theories have emerged that IOP variations could play as much a role in glaucoma progression as the mean level of IOP. The aim of the present study was to evaluate the direct effect of common daily activities on IOP-related profiles. Primary open-angle glaucoma and glaucoma suspect patients were prospectively enrolled from specialist clinics at the University of California San Diego (UCSD), USA.

View Article and Find Full Text PDF

Purpose: To address the unmet need of continuous IOP monitoring, a Pressure-Measuring Contact Lens (PMCL) was developed to measure IOP in millimeters of mercury (mmHg) continuously over 24 hours. The present study assessed the reliability of the novel PMCL.

Methods: In this prospective open-label clinical study, healthy and open-angle glaucoma (OAG) subjects were fitted with the PMCL, and pneumatonometry was performed on study eyes (in absence of the PMCL) and on fellow eyes before, during, and after provocative tests.

View Article and Find Full Text PDF

Objectives: To determine the effect of laser trabeculoplasty on peripapillary retinal nerve fibre layer thickness (RNFL), fovea avascular zone (FAZ), peripapillary and macular vessel density (VD) in glaucoma using with optical coherence tomography angiography (OCT-A).

Methods: This was a prospective observational study performed at the Glaucoma Research Centre, Montchoisi Clinic, Lausanne, Switzerland. Thirty-seven eyes with primary open-angle glaucoma from 21 patients were included.

View Article and Find Full Text PDF

Introduction: Pseudoexfoliative glaucoma (PEXG) is the most common cause of secondary open-angle glaucoma worldwide. It is more aggressive and often more resistant to conventional treatments than primary open-angle glaucoma, yet there is currently no clear consensus on best management practices. This review explores current literature on PEXG to assess the safety and efficacy of currently available surgical techniques, and discusses clinical considerations on the diagnosis and management of the disease.

View Article and Find Full Text PDF

Glaucoma management has changed dramatically over the last decades, through clinical advances and technological revolutions. This review discusses the latest innovations and challenges faced in the field around three major axes: minimally-invasive glaucoma surgery (MIGS), implantable sensors and injectable therapeutics. Indeed, the vast number of recently developed MIGS techniques has not only provided clinicians with a wide range of therapeutic options, but they have also enabled them to adjust their therapies more finely which may have contributed a more patient-centric decision-making process.

View Article and Find Full Text PDF

Purpose: To evaluate the 3-year treatment outcomes of XEN 45 gel stent in open-angle glaucoma patients.

Methods: In this prospective, single-centre interventional study, consecutive eyes with uncontrolled intraocular pressure (IOP) or signs of disease progression despite medical treatment underwent XEN implantation either alone or combined with phacoemulsification (Phaco + XEN).

Main Outcome Measures: Surgical success was defined as 'complete' when 36-month unmedicated IOP was ≤15 mmHg with a relative IOP reduction ≥ 20% from medicated baseline, while the definition of qualified success allowed no more medications than at baseline.

View Article and Find Full Text PDF

Aim: To investigate the reliability of anterior chamber angle (ACA) measurements in narrow angles and assess the effect of laser peripheral iridotomy (LPI) on these measurements using novel swept-source optical coherence tomography (SS-OCT) technology.

Materials And Methods: In this prospective observational study, patients with gonioscopically narrow angles were enrolled and scheduled for prophylactic LPI. Twelve ACA sections were obtained in each eye using SS-OCT (ANTERION, Heidelberg Engineering, Germany) before and after Nd:YAG LPI.

View Article and Find Full Text PDF

Purpose: The last decade has witnessed an unprecedented growth in glaucoma treatment options through the introduction of minimally invasive glaucoma surgeries (MIGS). The aim of the present review is to provide an understanding of the currently available MIGS and to examine what data are currently available to guide treatment choice.

Design: Meta-analysis and systematic review of randomized and non-randomized control trials.

View Article and Find Full Text PDF

Background/aims: To better understand seasonal and weekday intraocular pressure (IOP) variations, long-term daily IOP measurements were assessed in patients with glaucoma using an intraocular telemetric sensor.

Methods: This prospective, open-label, multicentre observational study analysed the IOP variation patterns in 22 eyes of 22 patients with primary open-angle glaucoma (67.8±6.

View Article and Find Full Text PDF

Purpose: Scarce data are available on the symmetry of 24-hour intraocular pressure (IOP) variations between fellow eyes of glaucoma patients, and such evidence could have profound consequences on the interpretation of monocular therapeutic trials. The objective is to evaluate the intereye correlation of continuously measured circadian IOP-related patterns in untreated glaucoma patients.

Methods: In this single-center prospective study, a total of 29 untreated patients with open-angle glaucoma underwent bilateral ambulatory 24-hour monitoring of IOP-related patterns using a contact lens sensor (CLS; SENSIMED Triggerfish).

View Article and Find Full Text PDF

Precis: The surgical outcome of iStent inject devices is associated with device protrusion within the anterior chamber. Schlemm canal (SC) dilatation has a prognostic value. iStent inject devices do not move within the first year after implantation.

View Article and Find Full Text PDF

Aim: The aim of this report is to explore the risk factors of XEN stent obstruction, suggesting the need for a stricter control of these factors and highlighting areas for further research.

Background: Despite its proven effectiveness and safety profile, XEN gel stents (Allergan Plc, Dublin, Ireland) can become obstructed. The causes and predicting factors for such obstructions still require further research.

View Article and Find Full Text PDF

Aim: Glaucoma drainage device (GDD) failure is usually rectified by the replacement of the entire device or using a tube extender, both of which were associated with postoperative complications. To minimize these risks, we developed a technique to replace the failing section of a tube while keeping the filtration plate in place, and without resorting to an extender clip.

Background: We describe the case of a 69-year-old man, whose left posttraumatic glaucoma was initially treated with a XEN-augmented Baerveldt procedure.

View Article and Find Full Text PDF