Publications by authors named "Keson Beng-Choon Tan"

Purpose: To investigate the rotational load fatigue performance of different implant diameters and abutment platforms of a one-size implant-abutment (OSIA) connection system.

Materials And Methods: Narrow-, regular-, and wide-diameter implants were tested with regular base (RB/WB) abutments of an OSIA system (BLX, Straumann). Wide-diameter implants (WDIs) were also tested with wide base (WB) abutments.

View Article and Find Full Text PDF

Purpose: This in vitro study investigated the effect of implant geometry and diameter on the rotational load fatigue performance of an implant system with an internal conical connection with microthreads.

Materials And Methods: Regular (4.2 mm) and wide-diameter (4.

View Article and Find Full Text PDF

Statement Of Problem: Some contemporary articulator systems claim to be highly precise in their interchangeability, with tolerances below 10 μm in vertical error; however, the claims have not been independently verified.

Purpose: The purpose of this study was to investigate the interchangeability of calibrated semiadjustable articulators in service over time.

Material And Methods: A calibrated mounting articulator served as the master articulator, while the test groups were used articulators with a minimum of 1-year use by predoctoral dental students (n=10); used articulators with a minimum of 1-year use by prosthodontic residents (n=10); and new articulators (n=10).

View Article and Find Full Text PDF

Purpose: To study the effect of implant angulation on 3D linear and absolute angular distortions of implant analogs in printed resin models and conventional stone casts.

Materials And Methods: Three sectional master models with two implants with total inter-implant angulations of 0°, 10°, and 20° were fabricated. For each master model, five conventional stone casts (CS) and printed resin models (PM) were fabricated (n = 5).

View Article and Find Full Text PDF

Purpose: To compare the esthetic outcomes of anterior implant-supported single crowns as evaluated by patients and clinicians of different specialties.

Materials And Methods: A total of 133 patients with 138 implant-supported crowns were recalled from the National Dental Centre Singapore Implant Registry to rate the esthetic outcomes of their restorations using a visual analog scale (VAS) questionnaire. Patients with crowns in the maxillary or mandibular canine-to-canine region with a contralateral natural tooth and minimum time in function of 6 months were recruited.

View Article and Find Full Text PDF

Purpose: Titanium-zirconium (Ti-Zr) alloy has been developed to strengthen the implant body, but clinically relevant information is still limited. The aim of this in vitro study was to compare the rotational load fatigue performance of implant-abutment connections in narrow-diameter (3.3-mm) and regular-diameter (4.

View Article and Find Full Text PDF

Objectives: Erosive tooth wear (ETW) is defined as the irreversible chemo-mechanical loss of dental hard tissues without plaque or bacteria and has been a growing phenomenon in the general population worldwide. The aim of this study was to determine the prevalence of ETW and the associated risk factors among young military personnel in Singapore.

Materials And Methods: This cross-sectional study consisted of a questionnaire and clinical examination of military personnel between 18 and 25 years.

View Article and Find Full Text PDF

Statement Of Problem: In the implant digital workflow, scan bodies provide the 3D position of digital implants in the virtual dental arch. However, limited evidence is available on scan body accuracy, selection, and usage.

Purpose: The purpose of this in vitro study was to evaluate the 3D positional accuracy of 4 intraoral and 6 laboratory scan body systems to the implants and laboratory replicas of an implant system under various torque magnitudes.

View Article and Find Full Text PDF

Purpose: To study the effect of implant analog system, print orientation, and analog holder radial offset on 3D linear and absolute angular distortions of implant analogs in 3D printed resin models.

Materials And Methods: A sectional master model simulating a 2-implant, 3-unit fixed prosthesis in a partially edentulous jaw was fabricated. Three implant analog systems for 3D printed resin models-Straumann (ST), Core3DCentres (CD) and Medentika (MD)-were tested.

View Article and Find Full Text PDF

Purpose: To visually and spectrophotometrically determine the differences in the shades of maxillary anterior implant crowns and peri-implant soft tissues compared to a natural teeth control group.

Materials And Methods: A total of 44 patients restored with single implant-supported restorations were assessed after at least 6 months in function. Images of the implant crowns, peri-implant soft tissues, and their controls were captured using a spectrophotometer (SpectroShade Micro, Medical High Technologies).

View Article and Find Full Text PDF

Purpose: To evaluate the survival and success rates of post-and-core restorations supporting fixed dental prostheses (FDPs) after a mean time in function of 7 years and to assess the incidences of biologic and technical complications.

Materials And Methods: Patients from the National Dental Center Singapore (NDCS) with endodontically treated premolars restored with post-retained FDPs from 2007 to 2009 were recruited from the Endodontic Registry and evaluated by three clinicians. A total of 265 patients with 329 treated premolars were examined clinically.

View Article and Find Full Text PDF

Purpose: This study compared the three-dimensional (3D) accuracy of conventional impressions with digital impression systems (intraoral scanners and dental laboratory scanners) for two different interimplant distances in maxillary edentulous arches.

Materials And Methods: Six impression systems comprising one conventional impression material(Impregum), two intraoral scanners (TRIOS and True Definition), and three dental laboratory scanners (Ceramill Map400, inEos X5, and D900) were evaluated on two completely edentulous maxillary arch master models (A and B) with six and eight implants, respectively. Centroid positions at the implant platform level were derived using either physical or virtual probe hits with a coordinate measuring machine.

View Article and Find Full Text PDF

Background: Symptoms of Temporomandibular Disorders (TMD) could affect oral health-related quality of life (OHRQoL) and psychological distress.

Objective: This study aims to determine the prevalence of TMD symptoms, and impact of type and number of TMD symptoms on OHRQoL and psychological states among Asian military personnel.

Method: The study was conducted across 12 military dental centres using self-administered questionnaire comprising demographical data, DC/TMD symptom questionnaire, OHIP-14 and DASS-21.

View Article and Find Full Text PDF

Aims: To determine the prevalence of sleep bruxism (SB) in adult obstructive sleep apnea (OSA) patients, to assess the association between SB and OSA in terms of sleep macrostructure and respiratory parameters, and to determine possible OSA risk factors for SB.

Methods: Type I polysomnographic data of 147 adult OSA patients (mean age 44.6 ± 12.

View Article and Find Full Text PDF

Purpose: To evaluate the 3D static articulation accuracy of 3 model scanner-CAD systems (Ceramill Map400 [AG], inEos X5 [SIR], Scanner S600 Arti [ZKN]) using a coordinate measuring machine (CMM). Trueness and precision for each system will be reported in Part I.

Materials And Methods: The master model simulated a single crown opposing a 3-unit fixed dental prosthesis.

View Article and Find Full Text PDF

Purpose: Accurate maxillomandibular relationship transfer is important for CAD/CAM prostheses. This study compared the 3D-accuracy of virtual model static articulation in three laboratory scanner-CAD systems (Ceramill Map400 [AG], inEos X5 [SIR], Scanner S600 Arti [ZKN]) using two virtual articulation methods: mounted models (MO), interocclusal record (IR).

Materials And Methods: The master model simulated a single crown opposing a 3-unit fixed partial denture.

View Article and Find Full Text PDF

Purpose: Prior studies have defined the accuracy of intraoral scanner (IOS) systems but the accuracy of the digital static interocclusal registration function of these systems has not been reported. This study compared the three-dimensional (3D) accuracy of the digital static interocclusal registration of 3 IOS systems using the buccal bite scan function.

Materials And Methods: Three IOS systems compared were 3M True Definition Scanner (TDS), TRIOS Color (TRC), and CEREC AC with CEREC Omnicam (CER).

View Article and Find Full Text PDF

This report describes the clinical and technical aspects in the oral rehabilitation of an edentulous patient with knife-edge ridge at the mandibular anterior edentulous region, using implant-retained overdentures. The application of computer-aided design and computer-aided manufacturing (CAD/CAM) in the fabrication of the overdenture framework simplifies the laboratory process of the implant prostheses. The Nobel Procera CAD/CAM System was utilised to produce a lightweight titanium overdenture bar with locator attachments.

View Article and Find Full Text PDF

Objective:: This study investigated the Weibull parameters and 5% fracture probability of direct, indirect composites, and CAD/CAM composites.

Material And Methods:: Discshaped (12 mm diameter x 1 mm thick) specimens were prepared for a direct composite [Z100 (ZO), 3M-ESPE], an indirect laboratory composite [Ceramage (CM), Shofu], and two CAD/CAM composites [Lava Ultimate (LU), 3M ESPE; Vita Enamic (VE), Vita Zahnfabrik] restorations (n=30 for each group). The specimens were polished, stored in distilled water for 24 hours at 37°C.

View Article and Find Full Text PDF

Statement Of Problem: In spite of its importance in prosthesis precision and quality, the 3-dimensional repositioning accuracy of cast mounting systems has not been reported in detail.

Purpose: The purpose of this study was to quantify the 3-dimensional repositioning accuracy of 6 selected cast mounting systems. Five magnetic mounting systems were compared with a conventional screw-on system.

View Article and Find Full Text PDF

Statement Of Problem: The marginal fit of crowns is a concern for clinicians, and there is no conclusive evidence of any one margin configuration yielding better results than others in terms of marginal fit.

Purpose: The purpose of this study was to evaluate the marginal fit with respect to gap and overhang of Y-TZP (yttria-stabilized tetragonal zirconia polycrystals) ceramic crowns and compare them with lithium disilicate pressable and complete metal crowns. The influence of margin configuration on the marginal fit was also evaluated.

View Article and Find Full Text PDF

Statement Of Problem: The minimum amount of resistance form required for the success of a clinical crown is unknown.There is little information on the fatigue performance of complete coverage restorations on natural tooth preparations cemented with different luting cements.

Purpose: The purpose of this study was to evaluate the effect of tooth preparation height and luting agent on resistance form using unidirectional load fatigue testing.

View Article and Find Full Text PDF

Statement Of Problem: Resin cements have gained popularity over the past few years because of their improved physical properties. There is a need to test these cements under fatigue loading, as there is growing recognition that fatigue testing is more clinically relevant than traditional monotonic static tests.

Purpose: This study investigated the load-fatigue performance of complete gold crowns cemented with 4 types of resin cement.

View Article and Find Full Text PDF

Introduction: Healthcare workers (HCWs) were at the frontline during the battle against Severe Acute Respiratory Syndrome (SARS). Understanding their fears and anxieties may hold lessons for handling future outbreaks, including acts of bioterrorism.

Method: We measured risk perception and impact on personal and work life of 15,025 HCWs from 9 major healthcare institutions during the SARS epidemic in Singapore using a self-administered questionnaire and Impact of Events Scale and analyzed the results with bivariate and multivariate statistics.

View Article and Find Full Text PDF