Purpose: To investigate the effect of selective retina therapy (SRT) on the release of AMD-relevant cell mediators, such as matrix metalloproteinases (MMPs), VEGF, and pigment epithelium derived factor (PEDF) using different laser spot sizes and densities.
Methods: Porcine RPE-choroid explants were treated with a pulsed 532 nm Nd:YAG laser using (1) large spot sizes, (2) small spot sizes with a high-density (hd) treatment, and (3) small spot sizes with a low-density (ld) treatment. Explants were cultivated in modified Ussing chambers.
Laser photocoagulation has been a treatment method for retinal diseases for decades. Recently, studies have demonstrated therapeutic benefits for subvisible effects. A treatment mode based on an automatic feedback algorithm to reliably generate subvisible and visible irradiations within a constant irradiation time is introduced.
View Article and Find Full Text PDFLaser photocoagulation is an established treatment for a variety of retinal diseases. However, when using the same irradiation parameter, the size and strength of the lesions are unpredictable due to unknown inter- and intraindividual optical properties of the fundus layers. The aim of this work is to investigate a feedback system to generate desired lesions of preselectable strengths by automatically controlling the irradiation time.
View Article and Find Full Text PDFPurpose: Conventional retinal photocoagulation produces irregular lesions and does not allow reliable control of ophthalmoscopically invisible lesions. We applied automatically controlled retinal photocoagulation, which allows to apply uniform lesions without titration, and aimed at five different predictable lesion intensities in a study on rabbit eyes.
Methods: A conventional 532-nm photocoagulation laser was used in combination with a pulsed probe laser.
Purpose: To correlate the long-term clinical effect of photocoagulation lesions after 6 months, as measured by their retinal damage size, to exposure parameters. We used optical coherence tomographic (OCT)-based lesion classes in order to detect and assess clinically invisible and mild lesions.
Methods: In this prospective study, 488 photocoagulation lesions were imaged in 20 patients.
Background And Objective: The rabbit is the most common animal model to study retinal photocoagulation lesions. We present a classification of retinal lesions from rabbits, that is based on optical coherence tomographic (OCT) findings, temperature data, and OCT-follow-up data over 3 months.
Materials And Methods: Four hundred eighty-six photocoagulation lesions (modified Zeiss Visulas® 532 nm CW laser, lesion diameter 133 µm, exposure duration 200 milliseconds or variable, power variable) were analyzed from six eyes of three chinchilla gray rabbits.
Purpose: To examine spectral domain optical coherence tomographic (OCT) and histological images from comparable retinal photocoagulation lesions in rabbits, and to correlate these images with comparable OCT images from patients.
Methods: 508 rabbit lesions were examined by HE-stained paraffin histology. 1019 rabbit lesions versus 236 patient lesions were examined by OCT, all at the time-points 1 hr, 1 week and 4 weeks after photocoagulation.
We conducted a study to correlate the retinal temperature rise during photocoagulation to the afterward detected tissue effect in optical coherence tomography (OCT). 504 photocoagulation lesions were examined in 20 patients. The retinal temperature increase was determined in real-time during treatment based on thermoelastic tissue expansion which was probed by repetitively applied ns laser pulses.
View Article and Find Full Text PDFLaser coagulation is a treatment method for many retinal diseases. Due to variations in fundus pigmentation and light scattering inside the eye globe, different lesion strengths are often achieved. The aim of this work is to realize an automatic feedback algorithm to generate desired lesion strengths by controlling the retinal temperature increase with the irradiation time.
View Article and Find Full Text PDFThe induced thermal damage in retinal photocoagulation depends on the temperature increase and the time of irradiation. The temperature rise is unknown due to intraocular variations in light transmission, scattering and grade of absorption in the retinal pigment epithelium (RPE) and the choroid. Thus, in clinical practice, often stronger and deeper coagulations are applied than therapeutically needed, which can lead to extended neuroretinal damage and strong pain perception.
View Article and Find Full Text PDFVisualizing retinal photocoagulation by real-time OCT measurements may considerably improve the understanding of thermally induced tissue changes and might enable a better reproducibility of the ocular laser treatment. High speed Doppler OCT with 860 frames per second imaged tissue changes in the fundus of enucleated porcine eyes during laser irradiation. Tissue motion, measured by Doppler OCT with nanometer resolution, was correlated with the temperature increase, which was measured non-invasively by optoacoustics.
View Article and Find Full Text PDFInvest Ophthalmol Vis Sci
June 2012
Purpose: Retinal laser photocoagulation carries the risk of overtreatment due to effect variation of identically applied lesions. The degree of coagulation depends on the induced temperature increase and on exposure time. We introduce temperature controlled photocoagulation (TCP), which uses optoacoustics to determine individually exposure times necessary to create reproducible lesions.
View Article and Find Full Text PDF