Aim: To evaluate the predictive value of preoperative echocardiographic parameters for occurrence of VAs in patients with preexisting ICD undergoing LVAD implantation.
Methods And Results: All consecutive patients (n = 264) with previous ICD who underwent LVAD surgery between May 2011 and December 2019 at our institution were included. The patients were predominantly male (89%) with NICM (59%) and a mean age of 59 ± 10 years.
The placement of cardiovascular implantable electronic devices (CIED) comes with a risk of adverse events (AE). AE comprise complications associated with the procedure and the device. CIED infection is a severe AE.
View Article and Find Full Text PDFIntroduction: Infection is a significant complication of cardiac implantable electronic device (CIED) therapy. The European TauroPace™ Registry investigates the safety and efficacy of TauroPace™ (TP), an antimicrobial solution containing taurolidine, designed to prevent CIED infections.
Methods: This multicenter study included patients undergoing CIED procedures at participating centers where TP was used as a disinfectant for external hardware surfaces and an antiseptic for irrigating surgical sites.
Purpose Of Review: Cardiovascular magnetic resonance (CMR) imaging excels in providing detailed three-dimensional anatomical information together with excellent soft tissue contrast and has already become a valuable tool for diagnostic evaluation, electrophysiological procedure (EP) planning, and therapeutical stratification of atrial or ventricular rhythm disorders. CMR-based identification of ablation targets may significantly impact existing concepts of interventional electrophysiology. In order to exploit the inherent advantages of CMR imaging to the fullest, CMR-guided ablation procedures (EP-CMR) are justly considered the ultimate goal.
View Article and Find Full Text PDFAims: Simplified ablation technologies for pulmonary vein isolation (PVI) are increasingly performed worldwide. One of the most common complications following PVI are vascular access-related complications. Lately, venous closure systems (VCSs) were introduced into clinical practice, aiming to reduce the time of bed rest, to increase the patients' comfort, and to reduce vascular access-related complications.
View Article and Find Full Text PDFAims: High-power-short-duration (HPSD) ablation is an effective treatment for atrial fibrillation but poses risks of thermal injuries to the oesophagus and vagus nerve. This study aims to investigate incidence and predictors of thermal injuries, employing machine learning.
Methods And Results: A prospective observational study was conducted at Leipzig Heart Centre, Germany, excluding patients with multiple prior ablations.
Fully CMR-guided electrophysiological interventions (EP-CMR) have recently been introduced but data on the optimal CMR imaging protocol are scarce. This study determined the clinical utility of 3D non-selective whole heart steady-state free precession imaging using compressed SENSE (nsWHcs) for automatic segmentation of cardiac cavities as the basis for targeted catheter navigation during EP-CMR cavo-tricuspid isthmus ablation. Fourty-two consecutive patients with isthmus-dependent right atrial flutter underwent EP-CMR radiofrequency ablations.
View Article and Find Full Text PDFBackground: Cardiac implantable electronic device (CIED) placement comes with certain complications. CIED infection is a severe adverse event related to CIED placement. In randomised controlled trials, the preoperative intravenous administration of antibiotics and the adjunctive use of an antibiotic mesh envelope resulted in significant reduction in infections related to cardiac implantable electronic devices.
View Article and Find Full Text PDFPacing Clin Electrophysiol
June 2023
Background: We recently described a novel pacemaker-mediated arrhythmia in Abbott cardiac implantable electronic devices (CIED), called pseudo-RNRVAS, that mimics repetitive non-reentrant ventriculoatrial synchrony (RNRVAS), but can appear in patients with ventriculoatrial (VA) block. It is caused by sinus-p-waves, trapped in the post-ventricular atrial refractory period (PVARP), which mimic VA conduction. The p-waves are followed by atrial pacing during the myocardial refractory time, which can trigger atrial fibrillation (AF).
View Article and Find Full Text PDFAims: Data on safety and efficacy of a non-fasting strategy in minimal invasive cardiac procedures are lacking. We assessed a non-fasting strategy compared with a fasting strategy regarding patient's well-being and safety in elective cardiac implantable electronic device (CIED) procedures.
Methods And Results: In this randomized, single-blinded clinical trial, 201 patients (non-fasting = 100, fasting = 101) with a mean age of 72.
Quality improvement plays a major role in healthcare, and numerous approaches have been developed to implement changes. However, the reasons for success or failure of the methods applied often remains obscure. Normalization process theory, recently developed in sociology, provides a flexible framework upon which to construct quality improvement.
View Article and Find Full Text PDFBackground: Cardiac resynchronization therapy (CRT) is widely used in atrial fibrillation (AF) patients and could impact rhythm stability.
Hypothesis: We aimed to identify predictors of sinus rhythm (SR) stability or AF progression in a real-word cohort of CRT-AF patients.
Methods: From 330 consecutive implantable cardioverter-defibrillator implantations due to ischemic or dilated cardiomyopathy, 65 (20%) patients with AF history (paroxysmal, n = 32) underwent a CRT implantation with an atrial electrode and were regularly followed every 4-6 months.
Introduction: Cardiac perforation is a rare complication of cardiac implantable electronic device (CIED) implantation. Transvenous revision of perforated leads is associated with the risk of cardiac tamponade and death. Little is known about periprocedural complications and outcome of these patients.
View Article and Find Full Text PDFPurpose: Signal-averaged ECG (SAECG) can detect inhomogeneous myocardial conduction in patients presenting with ventricular tachycardia (VT) after myocardial infarction. Radiofrequency ablation (RFCA) aims at elimination of the endocardial late potentials and non-inducibility of VT. Previously, we demonstrated that abnormal SAECG at baseline can return to normal after a successful VT ablation.
View Article and Find Full Text PDFBackground: Optimal timing of the atrioventricular delay in cardiac resynchronization therapy (CRT) can improve synchrony in patients suffering from heart failure. The purpose of this study was to evaluate the impact of SyncAV™ on electrical synchrony as measured by vectorcardiography (VCG) derived QRS metrics during bi-ventricular (BiV) pacing.
Methods: Patients implanted with a cardiac resynchronization therapy (CRT) device and quadripolar left ventricular (LV) lead underwent 12‑lead ECG recordings.
Background: Combinations of coronary heart disease (CHD) and other chronic conditions complicate clinical management and increase healthcare costs. The aim of this study was to evaluate gender-specific relationships between CHD and other comorbidities.
Methods: We analyzed data from the German Health Interview and Examination Survey (DEGS1), a national survey of 8152 adults aged 18-79 years.
Background: There are only limited data about peri-interventional pain during cardiac electrophysiological procedures without analgosedation. In this study, peri-interventional pain and recollection of it after the intervention were evaluated.
Methods: A total of 101 patients (43 electrophysiological/ablation procedures and 58 device surgeries) reported pain on a numerical rating scale (NRS; 0-10) before (pre), during (peri), and after (post) the intervention.
Competitive sports and intensive exercise are associated with adverse outcomes in patients with arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C). This study aimed to assess the role of exercise on long-term results of radiofrequency catheter ablation (RFCA) therapy of ventricular tachycardia (VT) in patients with ARVD/C. Exercise participation was evaluated by telephone or in-person interviews in patients from our ARVD/C registry with previous VT ablation (38 patients, 26 males, age 52.
View Article and Find Full Text PDFThe advantages of upgrade to cardiac resynchronisation therapy (CRT) have not been explored as carefully as the outcomes of de novo CRT implantations. Furthermore selection criteria for patients with the potential to benefit the most from this therapy are unknown. Therefore, we analyzed the long term outcome and its predictors in a real-world cohort receiving a CRT upgrade from previous pacemaker (PM) and defibrillator devices (ICD).
View Article and Find Full Text PDFAims: Transvenous lead extraction for cardiac implantable electronic devices (CIED) is of growing importance. Nevertheless, the optimal anaesthetic approach, general anaesthesia vs. deep sedation (DS), remains unresolved.
View Article and Find Full Text PDFBackground: Patient-specific programming of cardiac resynchronization therapy (CRT) is often neglected, despite significant nonresponse rates. The device-based SyncAV CRT algorithm dynamically adjusts atrioventricular delays to the intrinsic AV interval, reduced by a programmable offset, to accommodate each patient's changing needs.
Objective: The purpose of this study was to evaluate the acute effect of biventricular (BiV) pacing enhanced by SyncAV on electrical synchrony in a broad patient population.