Background: This study investigated the utility of thromboelastometry (ROTEM) in assessing hypofibrinolysis among septic patients, specifically the association of hypofibrinolysis, as determined by ROTEM, with septic disseminated intravascular coagulation (DIC), organ dysfunction, and clinical outcomes.
Methods: This single-center, retrospective analysis included adult septic patients admitted to Saga University Hospital from 2013 to 2017, with available ROTEM data. Hypofibrinolysis was assessed using the lysis index at 60 min (LI60) in extrinsic thromboelastometry (EXTEM).
To conduct an appropriate medical interview, education and clinical experience are necessary. The usefulness of computer-based medical diagnostic support systems has been reported in medical interviewing. However, only a few reports have actually applied these systems and noted changes in the quality of the medical interview of residents.
View Article and Find Full Text PDFBackground: Patients with coronavirus disease 2019 (COVID-19) occasionally develop respiratory failure and coagulopathy. We aimed to determine whether coagulation abnormalities at admission and during the course of hospitalization can predict the liberation from respiratory support in critically ill patients with COVID-19 by combining the results of rotational thromboelastometry (ROTEM) with standard laboratory tests.
Methods: This single-center, retrospective, observational study included 31 consecutive adult patients with COVID-19 who were admitted to the intensive care unit (ICU) and who required respiratory support between April 2021 and August 2021.
Background: Hemorrhagic complications in patients with coronavirus 19 disease (COVID-19) are infrequent but associated with a prognosis. This study aimed to elucidate the risk factors for bleeding complications in patients with COVID-19 using rotational thromboelastometry (ROTEM) parameters and blood tests performed at admission.
Methods: In total, 31 patients with severe COVID-19 treated intensively at Saga University Hospital were included in this study.
Background: Delirium has been shown to prolong the length of intensive care unit stay, hospitalization, and duration of ventilatory control, in addition to increasing the use of sedatives and increasing the medical costs. Although there have been a number of reports referring to risk factors for the development of delirium, no model has been developed to predict delirium in trauma patients at the time of admission. This study aimed to create a scoring system that predicts delirium in trauma patients.
View Article and Find Full Text PDFAim: In healthy adults, there are sufficient amounts of antithrombin in the blood to regulate thrombin. However, the effects of high concentrations of antithrombin on dose-dependent anticoagulation and platelet function have not been reported. In this study, we assessed platelet function and blood coagulation following high-dose antithrombin supplementation .
View Article and Find Full Text PDFBackground: Hyperbaric oxygen (HBO2) therapy was introduced nearly 300 years ago. However, its effect on thrombus formation is unclear. This may be because platelet and coagulation functions are unstable, yielding variable results; hence, accurate measurement is difficult.
View Article and Find Full Text PDFThe effect of the flow path geometry of the impeller on the lift-off and tilt of the rotational axis of the impeller against the hydrodynamic force was investigated in a centrifugal blood pump with an impeller supported by a single-contact pivot bearing. Four types of impeller were compared: the FR model with the flow path having both front and rear cutouts on the tip, the F model with the flow path having only a front cutout, the R model with only a rear cutout, and the N model with a straight flow path. First, the axial thrust and the movement about the pivot point, which was loaded on the surface of the impeller, were calculated using computational fluid dynamics (CFD) analysis.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
September 2015
The effect of a cutout on the pump pressure-flow characteristics and the impeller stability was quantified using computational fluid dynamics analysis in order to provide good hemocompatibility of the monopivot extracorporeal circulation pump. As a result, the following findings were clarified. The pump pressure is lower in the cutout model than in the no-cutout model.
View Article and Find Full Text PDF