Objectives: The purpose of this study was to define anterior mitral leaflet (AML) length and mitral ring characteristics associated with LVOT obstruction and PVL following MViR.

Background: Transcatheter Mitral Valve in Ring (MViR) procedural complications including parvalvular leak (PVL) and left ventricular outflow tract (LVOT) obstruction are frequent.

Methods: Clinical records, computer tomographic scans (CTs) and echocardiograms of consecutive MViR patients were retrospectively reviewed for anterior mitral leaflet length, CT-simulated neoLVOT, and aortomitral angle among patients with and without MViR-induced LVOT obstruction.

View Article and Find Full Text PDF

Background: There is a rich literature on insurance coverage and its impacts on health care. Many recent studies have examined the impacts of the Affordable Care Act (ACA) and found that it had positive effects on health insurance coverage and health care usage. Most of the literature, however, has focused on insurance coverage at a single point in time, while research on insurance instability is underrepresented, even though it could significantly impact health outcomes.

View Article and Find Full Text PDF

Prolyl aminodipeptidase (PepX) is an enzyme that hydrolyzes peptide bonds from the N-terminus of substrates when the penultimate amino-acid residue is a proline. Prolyl peptidases are of particular interest owing to their ability to hydrolyze food allergens that contain a high percentage of proline residues. PepX from Lactobacillus helveticus was cloned and expressed in Escherichia coli as an N-terminally His-tagged recombinant construct and was crystallized by hanging-drop vapor diffusion in a phosphate buffer using PEG 3350 as a precipitant.

View Article and Find Full Text PDF

Objectives: The purpose of this study was to evaluate the safety and efficacy of valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) for stentless bioprosthetic aortic valves (SBAVs) and to identify predictors of adverse events.

Background: ViV TAVR in SBAVs is associated with unique technical challenges and risks.

Methods: Clinical records and computer tomographic scans were retrospectively reviewed for procedural complications, predictors of coronary obstruction, mortality, and echocardiographic results.

View Article and Find Full Text PDF

Objective: The study objective was to analyze factors associated with left ventricular mass regression in patients undergoing aortic valve replacement with a newer bioprosthesis, the Trifecta valve pericardial bioprosthesis (St Jude Medical Inc, St Paul, Minn).

Methods: A total of 444 patients underwent aortic valve replacement with the Trifecta bioprosthesis from 2007 to 2009 at 6 US institutions. The clinical and echocardiographic data of 200 of these patients who had left ventricular hypertrophy and follow-up studies 1 year postoperatively were reviewed and compared to analyze factors affecting left ventricular mass regression.

View Article and Find Full Text PDF

Minocycline, a derivative of tetracycline, is a broad-spectrum antibiotic used in the treatment of various infections. Black discolouration of the skin, teeth, bones and the thyroid gland are sequelae of long-term minocycline therapy. We report an unusual case of minocycline-induced pigmentation of the aortic valve and sinuses of Valsalva.

View Article and Find Full Text PDF

Paravalvular aortic insufficiency (AI) is observed in the majority of patients undergoing transcatheter aortic valve replacement (TAVR). While paravalvular AI is most commonly modest following TAVR, moderate or severe AI was seen in 10.5% and 6.

View Article and Find Full Text PDF

Background And Aim Of The Study: The American College of Cardiology/American Heart Association (ACC/AHA) guidelines recommend a three-month administration of warfarin following bioprosthetic valve replacement (BVR). However, strong evidence supporting this recommendation is lacking, making process variation likely.

Methods: In the ANSWER Registry, a total of 386 patients who had received either Epic or Biocor BVRs between May 2007 and August 2008 at 40 centers was enrolled.

View Article and Find Full Text PDF

Background: The St Jude Medical Epic heart valve (St Jude Medical, Inc, St Paul, Minn) is a tricomposite glutaraldehyde-preserved porcine bioprosthesis. The St Jude Medical Biocor porcine bioprosthesis is the precursor valve to the St Jude Medical Epic valve. The Epic valve is identical to the Biocor valve except that it is treated with Linx AC ethanol-based calcium mitigation therapy.

View Article and Find Full Text PDF

Percutaneous closure of an atrial septal defect has become increasingly popular among interventional cardiologists. With this relatively new technology being more widespread, it is important to acknowledge any device-related complications. We report a case of severe bronchospasm secondary to a metal allergy after an atrial septal defect device closure requiring device removal.

View Article and Find Full Text PDF

Objective: Risk of morbidity and mortality after coronary artery bypass graft surgery (CABG) is higher in patients with clinical diabetes mellitus (DM). We evaluated whether outcomes are affected by postoperative hyperglycemia in CABG patients independent of preoperative DM diagnosis.

Research Design And Methods: A total of 2297 consecutive CABG patients were studied.

View Article and Find Full Text PDF

Objective: This study compares clinical results of the standard Maze III operation, a highly effective treatment for atrial fibrillation, to less complex variations of the Maze III operation utilizing unipolar and bipolar radiofrequency ablation and pulmonary vein isolation.

Methods: Records were reviewed of 377 patients who had operations for treatment of atrial fibrillation at a single institution over a 10-year period. Standard Maze III was performed in 220 patients, unipolar radiofrequency Maze III in 60, bipolar radiofrequency Maze III in 65, and radiofrequency pulmonary vein isolation in 32.

View Article and Find Full Text PDF

Background: Determining which pretransplantation (TX) characteristics predict the development of chronic renal dysfunction (CRD) or death after heart TX would enable more accurate risk assessment at the time of candidate evaluation.

Methods: A cohort of 278 patients underwent TX in three hospitals between 1993 and 2002. Predictive models for CRD (serum creatinine consistently above 2 mg/dL) and allograft loss (death or re-TX) were constructed using logistic and Cox regression, respectively.

View Article and Find Full Text PDF

Background: A variety of indications (eg, prosthetic heart valves, atrial fibrillation, etc.) exist for the use of unfractionated heparin (UFH) and enoxaparin (ENOX) in the early postoperative period following open-heart surgery. However, the overall postoperative risk for hemorrhage from the use of UFH and ENOX are not known.

View Article and Find Full Text PDF

Background: Enoxaparin has become an attractive therapy for use during acute coronary syndrome (ACS) because of its potential superior efficacy over unfractionated heparin (UFH), its longer activity, and its subcutaneous route of administration. However, because a significant number of patients presenting with ACS may be sent directly to open heart surgery while still on anticoagulation, it is important to understand any potential bleeding risks that may be associated with the use of enoxaparin under these circumstances.

Methods: From 1998 to 2001, 1159 consecutive patients presenting with an acute coronary syndrome who received either UFH (n=1008) or enoxaparin (n=151) before proceeding to open heart surgery for urgent therapy during the same hospitalization were included in this study.

View Article and Find Full Text PDF

Transverse sternal nonunion is a complication of sternal fracture or partial sternotomy, and requires surgical treatment. Three patients with repeated failure of standard sternal repair were treated with a technique using metal plates and autogenous bone graft, which resulted in bone union in all patients. Metal plating of the sternum, accompanied by autogenous bone graft, is an effective method of treating transverse sternal nonunion.

View Article and Find Full Text PDF

Background: The Artificial Valve Endocarditis Reduction Trial (AVERT) was designed to compare endocarditis rates in Silzone versus conventional valves. Recruitment ended January 21, 2000, because of higher rates of paravalvular leakage in patients receiving the Silzone prosthesis. The present analysis determined late event rates that might be used in the management of approximately 36,000 patients who have received the Silzone prosthesis.

View Article and Find Full Text PDF