Publications by authors named "Kenny Ong Kheng Yee"

Background: The NEURON (Neuropsychiatry and Neuromodulation Unit) electroconvulsive therapy electroencephalogram (ECT-EEG) Algorithmic Rating Scale (NEARS) is a step-by-step approach to ictal electroencephalogram visual pattern recognition of seizure adequacy based on recruitment, amplitude, symmetry, duration and degree of post-ictal suppression. The objectives of this clinical audit were to determine the degree of agreement on the NEARS operational criteria between two neuropsychiatrists, the reliability of electroconvulsive therapy practitioners' administration of NEARS during ECT procedures and the correlation of NEARS scores with Clinical Global Impression scale scores after each ECT treatment session.

Methods: Systematic random sampling was conducted.

View Article and Find Full Text PDF