Individual ion mass spectrometry (IMS) is the Orbitrap-based extension of the niche mass spectrometry technique known as charge detection mass spectrometry (CDMS). While traditional CDMS analysis is performed on in-house-built instruments such as the electrostatic linear ion trap, IMS extends CDMS analysis to Orbitrap analyzers, allowing charge detection analysis to be available to the scientific community at large. IMS simultaneously measures the mass-to-charge ratios (m/z) and charges (z) of hundreds to thousands of individual ions within one acquisition event, creating a spectral output directly into the mass domain without the need for further spectral deconvolution.
View Article and Find Full Text PDFJ Am Soc Mass Spectrom
December 2024
Top-down mass spectrometry (TDMS) of intact proteins and antibodies enables direct determination of truncations, sequence variants, post-translational modifications, and disulfides without the need for any proteolytic cleavage. While mass deconvolution of top-down tandem mass spectra is typically used to identify fragment masses for matching to candidate proteoforms, larger molecules such as monoclonal antibodies can produce many fragment ions, making spectral interpretation challenging. Here, we explore an alternative approach for proteoform spectral matching that is better suited for larger protein analysis.
View Article and Find Full Text PDFModern mass spectrometry technology allows for extensive sequencing of the ~ 25 kDa subunits of monoclonal antibodies (mAbs) produced by IdeS proteolysis followed by disulfide bond reduction, an approach known as middle-down mass spectrometry (MD MS). However, the spectral congestion of tandem mass spectra of large polypeptides dramatically complicates fragment ion assignment. Here, we report the development and benchmark of an MD MS strategy based on the combination of different ion fragmentation techniques with proton transfer charge reduction (PTCR) to simplify the gas-phase sequencing of mAb subunits.
View Article and Find Full Text PDFLiquid chromatography-mass spectrometry (LC-MS) intact mass analysis and LC-MS/MS peptide mapping are decisional assays for developing biological drugs and other commercial protein products. Certain PTM types, such as truncation and oxidation, increase the difficulty of precise proteoform characterization owing to inherent limitations in peptide and intact protein analyses. Top-down MS (TDMS) can resolve this ambiguity via fragmentation of specific proteoforms.
View Article and Find Full Text PDFExisting mass spectrometric assays used for sensitive and specific measurements of target proteins across multiple samples, such as selected/multiple reaction monitoring (SRM/MRM) or parallel reaction monitoring (PRM), are peptide-based methods for bottom-up proteomics. Here, we describe an approach based on the principle of PRM for the measurement of intact proteoforms by targeted top-down proteomics, termed proteoform reaction monitoring (PfRM). We explore the ability of our method to circumvent traditional limitations of top-down proteomics, such as sensitivity and reproducibility.
View Article and Find Full Text PDFThe molecular identification of tissue proteoforms by top-down mass spectrometry (TDMS) is significantly limited by throughput and dynamic range. We introduce AutoPiMS, a single-ion MS based multiplexed workflow for top-down tandem MS (MS) directly from tissue microenvironments in a semi-automated manner. AutoPiMS directly off human ovarian cancer sections allowed for MS identification of 73 proteoforms up to 54 kDa at a rate of <1 min per proteoform.
View Article and Find Full Text PDFBlood serum and plasma are arguably the most commonly analyzed clinical samples, with dozens of proteins serving as validated biomarkers for various human diseases. Top-down proteomics may provide additional insights into disease etiopathogenesis since this approach focuses on protein forms, or proteoforms, originally circulating in blood, potentially providing access to information about relevant post-translational modifications, truncations, single amino acid substitutions, and many other sources of protein variation. However, the vast majority of proteomic studies on serum and plasma are carried out using peptide-centric, bottom-up approaches that cannot recapitulate the original proteoform content of samples.
View Article and Find Full Text PDFAnalysis of intact proteins by mass spectrometry enables direct quantitation of the specific proteoforms present in a sample and is an increasingly important tool for biopharmaceutical and academic research. Interpreting and quantifying intact protein species from mass spectra typically involves many challenges including mass deconvolution and peak processing as well as determining optimal spectral averaging parameters and matching masses to theoretical proteoforms. Each of these steps can present informatic hurdles, as parameters often need to be tailored specifically to the data sets.
View Article and Find Full Text PDFNative mass spectrometry has recently moved alongside traditional structural biology techniques in its ability to provide clear insights into the composition of protein complexes. However, to date, limited software tools are available for the comprehensive analysis of native mass spectrometry data on protein complexes, particularly for experiments aimed at elucidating the composition of an intact protein complex. Here, we introduce ProSight Native as a start-to-finish informatics platform for analyzing native protein and protein complex data.
View Article and Find Full Text PDFThe high-throughput quantification of intact proteoforms using a label-free approach is typically performed on proteins in the 0-30 kDa mass range extracted from whole cell or tissue lysates. Unfortunately, even when high-resolution separation of proteoforms is achieved by either high-performance liquid chromatography or capillary electrophoresis, the number of proteoforms that can be identified and quantified is inevitably limited by the inherent sample complexity. Here, we benchmark label-free quantification of proteoforms of by applying gas-phase fractionation (GPF) via field asymmetric ion mobility spectrometry (FAIMS).
View Article and Find Full Text PDFDeconvolution from intact protein mass-to-charge spectra to mass spectra is essential to generate interpretable data for mass spectrometry (MS) platforms coupled to ionization sources that produce multiply charged species. Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) can be used to analyze intact proteins in multiwell microtiter plates with speed matching small molecule analyses (at least 1 Hz). However, the lack of compatible deconvolution software has limited its use in high-throughput screening applications.
View Article and Find Full Text PDFThe effectiveness of any proteomics database search depends on the theoretical candidate information contained in the protein database. Unfortunately, candidate entries from protein databases such as UniProt rarely contain all the post-translational modifications (PTMs), disulfide bonds, or endogenous cleavages of interest to researchers. These omissions can limit discovery of novel and biologically important proteoforms.
View Article and Find Full Text PDFThe successful prospective incorporation of in vitro transporter kinetics in physiologically based pharmacokinetic (PBPK) models to describe drug disposition remains challenging. Although determination of scaling factors to extrapolate in vitro to in vivo transporter kinetics has been facilitated by quantitative proteomics, no robust assessment comparing membrane recoveries between different cells/tissues has been made. HEK293 cells overexpressing OCT2, MATE1, and MATE2K or human kidney cortex were homogenized and centrifuged to obtain the total membrane fractions, which were subsequently subjected to liquid-liquid extraction followed by centrifugation and precipitation to isolate plasma membrane fractions.
View Article and Find Full Text PDFObtaining extensive sequencing of an intact protein is essential in order to simultaneously determine both the nature and exact localization of chemical and genetic modifications which distinguish different proteoforms arising from the same gene. To effectively achieve such characterization, it is necessary to take advantage of the analytical potential offered by the top-down mass spectrometry approach to protein sequence analysis. However, as a protein increases in size, its gas-phase dissociation produces overlapping, low signal-to-noise fragments.
View Article and Find Full Text PDFProtein fragmentation is a critical component of top-down proteomics, enabling gene-specific protein identification and full proteoform characterization. The factors that influence protein fragmentation include precursor charge, structure, and primary sequence, which have been explored extensively for collision-induced dissociation (CID). Recently, noticeable differences in CID-based fragmentation were reported for native versus denatured proteins, motivating the need for scoring metrics that are tailored specifically to native top-down mass spectrometry (nTDMS).
View Article and Find Full Text PDFAn Orbitrap-based ion analysis procedure determines the direct charge for numerous individual protein ions to generate true mass spectra. This individual ion mass spectrometry (IMS) method for charge detection enables the characterization of highly complicated mixtures of proteoforms and their complexes in both denatured and native modes of operation, revealing information not obtainable by typical measurements of ensembles of ions.
View Article and Find Full Text PDFCharge detection mass spectrometry (CDMS) is mainly utilized to determine the mass of intact molecules. Previous applications of CDMS have determined the mass-to-charge ratio and the charge of large polymers, DNA molecules, and native protein complexes, from which corresponding mass values could be assigned. Recent advances have demonstrated that CDMS using an Orbitrap mass analyzer yields the reliable assignment of integer charge states that enables individual ion mass spectrometry (IMS) and spectral output directly into the mass domain.
View Article and Find Full Text PDFMulticellular tumor spheroids have been increasingly used by researchers to produce more physiologically relevant experimental environments. However, tracking of spheroid growth and treatment-induced volume reduction has not been readily adopted. Here, squamous carcinoma cells were seeded at different starting cell numbers with growth and reduction kinetics monitored using live cell imaging.
View Article and Find Full Text PDFTop-down proteomics studies intact proteoform mixtures and offers important advantages over more common bottom-up proteomics technologies, as it avoids the protein inference problem. However, achieving complete molecular characterization of investigated proteoforms using existing technologies remains a fundamental challenge for top-down proteomics. Here, we benchmark the performance of ultraviolet photodissociation (UVPD) using 213 nm photons generated by a solid-state laser applied to the study of intact proteoforms from three organisms.
View Article and Find Full Text PDFJ Am Soc Mass Spectrom
November 2019
Charge detection mass spectrometry (CDMS) of low-level signals is currently limited to the analysis of individual ions that generate a persistent signal during the entire observation period. Ions that disintegrate during the observation period produce reduced frequency domain signal amplitudes, which lead to an underestimation of the ion charge state, and thus the ion mass. The charge assignment can only be corrected through an accurate determination of the time of ion disintegration.
View Article and Find Full Text PDF