Publications by authors named "Kenneth J Cavanaugh"

Objective: This observational cohort study examined outcomes after peripheral vascular intervention (PVI) with paclitaxel coated devices (PCD) and non-PCD, and evaluated heterogeneity of treatment effect in populations of interest.

Methods: The study included patients undergoing percutaneous transluminal angioplasty and or stent placement between 1 October 2015 and 31 December 2018 in the Vascular Quality Initiative Registry linked to Medicare claims. It determined differences in patient mortality and ipsilateral major amputation after PVI with PCD and non-PCD using Kaplan-Meier analyses and Cox regressions with inverse probability weighting in three cohorts: (A) patients treated for femoropopliteal or infrapopliteal occlusive disease with or without any other concurrent treatment (n = 11 452); (B) those treated for isolated superficial femoral or popliteal artery disease (n = 5 519); and (C) patients with inclusion criteria designed to approximate RCT populations (n = 2 278).

View Article and Find Full Text PDF

Successful translation of new and innovative medical products from concept to clinical use is a complex endeavor that requires understanding and overcoming a variety of challenges. In particular, regulatory pathways and processes are often unfamiliar to academic researchers and start-ups, and even larger companies. Growing evidence suggests that the successful translation of ideas to products requires collaboration and cooperation between clinicians, researchers, industry, and regulators.

View Article and Find Full Text PDF

Background: Retrievable filters are increasingly implanted for prophylaxis in patients without pulmonary embolism (PE) but who may be at transient risk. These devices are often not removed after the risk of PE has diminished. This study employs decision analysis to weigh the risks and benefits of retrievable filter use as a function of the filter's time in situ.

View Article and Find Full Text PDF

We measured stretch-induced changes in transepithelial permeability in vitro to uncharged tracers 1.5-5.5 A in radius to identify a critical stretch threshold associated with failure of the alveolar epithelial transport barrier.

View Article and Find Full Text PDF

Mechanical ventilation with high tidal volumes has been shown to contribute to the formation or worsening of interstitial and alveolar edema. Previously we showed that application of large biaxial deformations in vitro perturbs the concentration and distribution of functional tight junction proteins in alveolar epithelial cells. Using a novel method, we determined that applied epithelial strain increases paracellular permeability in a dose- and rate-dependent manner.

View Article and Find Full Text PDF