Optical spectroscopic imaging of biological systems has important applications in medical diagnosis, biochemistry, and image-guided surgery. Vibrational spectroscopy, such as Raman scattering, provides high chemical selectivity but is limited by weak signals and a large fluorescence background. Fluorescence imaging is often used by introducing specific dyes in biological systems to label different system parts and to increase the image contrast.
View Article and Find Full Text PDFAlterations in ocular blood flow have been implicated in mechanisms that lead to vision loss in patients with various ocular disorders such as diabetic retinopathy, glaucoma, and age-related macular degeneration. Assessment of retinal and choroidal blood flow is also a window to evaluate systemic diseases that affect microvasculature. Quantification and qualification of the blood flow in the retina and choroid help us understand pathophysiology, stratify disease risk, and monitor disease progression in these disorders.
View Article and Find Full Text PDFUnderstanding the delivered cellular dose of nanoparticles is imperative in nanomedicine and nanosafety, yet is known to be extremely complex because of multiple interactions between nanoparticles, their environment, and the cells. Here, we use 3-D reconstruction of agglomerates preserved by cryogenic snapshot sampling and imaged by electron microscopy to quantify the "bioavailable dose" that is presented at the cell surface and formed by the process of individual nanoparticle sequestration into agglomerates in the exposure media. Critically, using 20 and 40 nm carboxylated polystyrene-latex and 16 and 85 nm silicon dioxide nanoparticles, we show that abrupt, dose-dependent "tipping points" in agglomeration state can arise, subsequently affecting cellular delivery and increasing toxicity.
View Article and Find Full Text PDFErythrocyte abundance, mobility, and carrying capacity make them attractive as a platform for blood analyte sensing as well as for drug delivery. Sensor-loaded erythrocytes, dubbed erythrosensors, could be reinfused into the bloodstream, excited noninvasively through the skin, and used to provide measurement of analyte levels in the bloodstream. Several techniques to load erythrocytes, thus creating carrier erythrocytes, exist.
View Article and Find Full Text PDFCross-system comparisons of drug delivery vectors are essential to ensure optimal design. An in-vitro experimental protocol is presented that separates the role of the delivery vector from that of its cargo in determining the cell response, thus allowing quantitative comparison of different systems. The technique is validated through benchmarking of the dose-response of human fibroblast cells exposed to the cationic molecule, polyethylene imine (PEI); delivered as a free molecule and as a cargo on the surface of CdSe nanoparticles and Silica microparticles.
View Article and Find Full Text PDFBrillouin microspectroscopy is a powerful technique for noninvasive optical imaging. In particular, Brillouin microspectroscopy uniquely allows assessing a sample's mechanical properties with microscopic spatial resolution. Recent advances in background-free Brillouin microspectroscopy make it possible to image scattering samples without substantial degradation of the data quality.
View Article and Find Full Text PDFThe layer-by-layer modification of ≈5 nm mercaptocarboxylic acid stabilized gold nanoparticles was studied in an effort to illustrate effective means to overcome practical issues in handling and performing surface modification of such extremely small materials. To accomplish this, each layer deposition cycle was separated into a multi-step process wherein solution pH was controlled in two distinct phases of polyelectrolyte adsorption and centrifugation. Additionally, a solvent precipitation step was introduced to make processing more amenable by concentrating the sample and exchanging solution pH before ultracentrifugation.
View Article and Find Full Text PDFThe recombinant protein Ultrabithorax (Ubx), a Hox transcription factor, self-assembles into biocompatible materials that are remarkably extensible and strong. Here, we demonstrate that the strength of Ubx materials is due to intermolecular dityrosine bonds. Ubx materials auto-fluoresce blue, a characteristic of dityrosine, and bind dityrosine-specific antibodies.
View Article and Find Full Text PDFUnderstanding the effect of variability in the interaction of individual cells with nanoparticles on the overall response of the cell population to a nanoagent is a fundamental challenge in bionanotechnology. Here, we show that the technique of time-resolved, high-throughput microscopy can be used in this endeavor. Mass measurement with single-cell resolution provides statistically robust assessments of cell heterogeneity, while the addition of a temporal element allows assessment of separate processes leading to deconvolution of the effects of particle supply and biological response.
View Article and Find Full Text PDFWe have developed a low-cost technique using a conventional microwave oven to grow layered basic zinc acetate (LBZA) nanosheets (NSs) from a zinc acetate, zinc nitrate and HMTA solution in only 2 min. The as-grown crystals and their pyrolytic decomposition into ZnO nanocrystalline NSs are characterized by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), atomic force microscopy (AFM), X-ray diffraction (XRD) and photoluminescence (PL). SEM and AFM measurements show that the LBZA NSs have typical lateral dimensions of 1 to 5 μm and thickness of 20 to 100 nm.
View Article and Find Full Text PDFQuantum Dots (QDs) stabilized with dihydrolipoic acid (DHLA) were used as a template for layer-by-layer (LbL) modification to study the effect on the QD optical properties. We studied several different polyelectrolytes to determine that large quantities of monodisperse DHLA-QDs could only be obtained with the weak polyelectrolyte pair of poly(allylamine hydrochloride) (PAH) and poly(acrylic acid) (PAA). The key to this success was the development of a two-step method to split the LbL process into adsorption and centrifugation phases, which require different pH solutions for optimum success.
View Article and Find Full Text PDFIn this report, a technique for rapid synthesis of ZnO microstructures by microwave-assisted heating of precursors at hydrothermal conditions is demonstrated. Further, the reaction mechanism for the growth of ZnO microstructures is analyzed. An accelerated rate of reaction obtained using microwaves enables a dissolution-recrystallization mechanism for generation of one dimensional (1D) rod-like structures, thereby showing that time of reaction can be used to dictate ZnO microstructure morphology.
View Article and Find Full Text PDFThe Amsterdam discrete dipole approximation (ADDA) is used to study the effects of an inhomogeneous refractive index in the surrounding medium of a microspherical resonator on the quality and position of the whispering gallery modes (WGMs). The model consists of a polystyrene microsphere with a refractive index, n, of 1.587 surrounded by water (n=1.
View Article and Find Full Text PDFIncorporation of nanoparticles during the hierarchical self-assembly of protein-based materials can impart function to the resulting composite materials. Herein we demonstrate that the structure and nanoparticle distribution of composite fibers are sensitive to the method of nanoparticle addition and the physicochemical properties of both the nanoparticle and the protein. Our model system consists of a recombinant enhanced green fluorescent protein-Ultrabithorax (EGFP-Ubx) fusion protein and luminescent CdSe-ZnS core-shell quantum dots (QDs), allowing us to optically assess the distribution of both the protein and nanoparticle components within the composite material.
View Article and Find Full Text PDFWhen CdSe/ZnS-polyethyleneimine (PEI) quantum dots (QDs) are microencapsulated in polymeric microcapsules, human fibroblasts are protected from acute cytotoxic effects. Differences in cellular morphology, uptake, and viability were assessed after treatment with either microencapsulated or unencapsulated dots. Specifically, QDs contained in microcapsules terminated with polyethylene glycol (PEG) mitigate contact with and uptake by cells, thus providing a tool to retain particle luminescence for applications such as extracellular sensing and imaging.
View Article and Find Full Text PDFA need exists for a long-term, minimally-invasive system to monitor blood analytes. For certain analytes, such as glucose in the case of diabetics, a continuous system would help reduce complications. Current methods suffer significant drawbacks, such as low patient compliance for the finger stick test or short lifetime (i.
View Article and Find Full Text PDFTwo-photon-excited fluorescence and second-harmonic generation are characterized as a function of laser pulse duration as short as sub-10-fs. A comparative study is performed where pulse duration is varied by introducing dispersion, as reported previously, and by tailoring pulse spectral width and minimizing its time-bandwidth product (transform-limited pulses). Experimental data and calculations show that characterizing a two-photon signal with the two schemes to vary pulse duration measures different phenomena.
View Article and Find Full Text PDFForster resonance energy transfer (FRET) between quantum dot (QD) donors and red fluorescent protein (RFP)-tagged integrin acceptors in live cells is reported for the first time. A silica microsphere was coated with CdSeZnS QDs and mounted to the cantilever of an atomic force microscope (AFM). The QD microsphere is then conjugated with fibronectin to bind with RFP-alphav integrins expressed on the surface of HeLa cells.
View Article and Find Full Text PDFWe present a refractometric sensor based on quantum dot-embedded polystyrene microspheres. Optical resonances within a microsphere, known as whispering-gallery modes (WGMs), produce narrow spectral peaks. For sensing applications, spectral shifts of these peaks are sensitive to changes in the local refractive index.
View Article and Find Full Text PDFNew methods of biological analyte sensing are needed for development of miniature biosensors that are highly sensitive and require minimal sample preparation. One technique employs optical resonances, known as whispering gallery modes (WGMs), in spherical or cylindrical microstructures. The spectral positions of these resonant modes are very sensitive to the local refractive index and spectral shifts may be used to sense changes in the index.
View Article and Find Full Text PDFIEEE Trans Nanobioscience
March 2009
We report a novel technique of directly coating colloidal CdSe/ZnS core/shell quantum dots (QDs) with silk fibroin (SF), a protein derived from the Bombyx mori silk worm. The approach results in protein-modified QDs with little or no particle aggregation, and mitigates the issue of biocompatibility. QDs have desirable optical properties, such as narrow-band emission, broadband absorption, high quantum yield, and high resistance to photobleaching.
View Article and Find Full Text PDFMeasurements and predictions are reported to understand large variations in evanescent wave (EW) scattering intensities between different particles from the same batch of single mode, polydisperse colloids. Measured EW scattering intensity distributions are obtained for three different micrometer sized latex particles irreversibly deposited onto glass surfaces. Predicted EW scattering intensity distributions are obtained using measured particle size distributions as input in a Mie theory for the three-dimensional scattering of a sphere under EW illumination.
View Article and Find Full Text PDFWe explore the hypothesis that shape factors can be used as tools to probe disease progression in addition to being used for simple classification. We define and apply a new shape factor to digital images of tumor cross sections of progressive rat hepatoma. Using a number of standard pathological measures, each image is also associated with a "disease time," a continuous variable between 0 and 1 with 0 being disease initiation and 1 being a near-fatal condition.
View Article and Find Full Text PDF