Publications by authors named "Kenigsberg D"

Background: Despite their improved safety, by and large, cardiac electrophysiology procedures including catheter ablation (CA), are presently performed in hospital outpatient departments.

Objective: This large multicenter study investigated the safety and outcomes associated with various cardiac electrophysiology procedures performed at 6 ambulatory surgery centers (ASCs), primarily during the coronavirus disease 2019 pandemic under the Center for Medicare and Medicaid Services Hospitals Without Walls program.

Methods: We retrospectively analyzed the outcomes from consecutive electrophysiology procedures performed in ASCs with same-day discharge, including transesophageal echocardiography, cardioversion, cardiac implantable electronic device (CIED) implantation, electrophysiology studies, and CA for atrial fibrillation (AF), atrial flutter (AFL)/supraventricular tachycardia, ventricular premature complexes (VPCs), and atrioventricular node.

View Article and Find Full Text PDF

Background: In recent years, there has been increased focus on the development of safe and effective strategies to minimize and ultimately eliminate fluoroscopy use in the electrophysiology lab due to the inherent risks to patients and staff associated with this imaging source. However, studies examining these innovative fluoroless strategies for pulmonary vein isolation (PVI) using catheters without direct 3D mapping system integration are lacking. We sought to develop a method to perform zero-fluoroscopy laser balloon PVI for patients with atrial fibrillation (AF), and to test the safety and efficacy of this approach.

View Article and Find Full Text PDF

Introduction: With the increasing adoption of left atrial appendage occlusion (LAAO) procedures and the eligibility of patients for pulmonary vein isolation (PVI) post device placement, we examined the feasibility and safety of laser balloon (LB) for PVI in patients with prior LAAO.

Methods: We retrospectively examined consecutive patients with paroxysmal or persistent, drug-resistant atrial fibrillation (AF) who underwent LB PVI, after Watchman FLX device implantation at Rush University Medical Center between January 2020 and December 2021.

Results: Seven patients (four persistent and three paroxysmal) with a mean age of 64 ± 11 years, predominantly male sex (86%), were included in the study.

View Article and Find Full Text PDF

Background: Persistent atrial fibrillation (AF) is associated with high recurrence rates of AF and atypical atrial flutters or tachycardia (AFT) postablation. Laser balloon (LB) ablation of the pulmonary vein (PV) ostia has similar efficacy as radiofrequency wide area circumferential ablation (RF-WACA); however, an approach of LB wide area circumferential ablation (LB-WACA) may further improve success rates.

Objective: To evaluate freedom from atrial tachyarrhythmia (AFT/AF) recurrence postablation using RF-WACA versus LB-WACA in persistent AF patients.

View Article and Find Full Text PDF

Catheter-based ablation techniques have a well-established role in atrial fibrillation (AF) management. The prevalence and impact of AF is increasing globally, thus mandating an emphasis on improving ablation techniques through innovation. One key area of ongoing evolution in this field is the use of laser energy to perform pulmonary vein isolation during AF catheter ablation.

View Article and Find Full Text PDF

Background: Pulmonary vein isolation (PVI) via catheter ablation is an approved therapy for patients with drug-refractory and symptomatic atrial fibrillation (AF). Furthermore, cryoballoon is now considered to be as effective as focal radiofrequency catheter ablation. This study examines the second-generation cryoballoon performance in a US multicenter review of real-world practices.

View Article and Find Full Text PDF

Background: Antitachycardia pacing (ATP) in implantable cardioverter-defibrillators (ICD) decreases patient shock burden but has recognized limitations. A new automated ATP (AATP) based on electrophysiological first principles was designed. The study objective was to assess the feasibility and safety of AATP in ambulatory ICD patients.

View Article and Find Full Text PDF

Background: There are no recommendations on the optimal dosing for cryoablation of atrial fibrillation (Cryo-AF).

Objective: The purpose of this study was to develop and prospectively test a Cryo-AF dosing protocol guided exclusively by time-to-pulmonary vein (PV) isolation (TT-PVI) in patients undergoing a first-time Cryo-AF.

Methods: In this multicenter study, we examined the acute/long-term safety/efficacy of Cryo-AF using the proposed dosing algorithm (Cryo-AF; n = 355) against a conventional, nonstandardized approach (Cryo-AF; n = 400) in a nonrandomized fashion.

View Article and Find Full Text PDF

Background: Implantable cardioverter defibrillators (ICDs) must establish a balance between delivering appropriate shocks for ventricular tachyarrhythmias and withholding inappropriate shocks for lead-related oversensing ("noise"). To improve the specificity of ICD therapy, manufacturers have developed proprietary algorithms that detect lead noise. The SecureSense RV Lead Noise discrimination (St.

View Article and Find Full Text PDF

Background: Limited data exist on cryoablation of atrial fibrillation (Cryo-AF) using the newly available third-generation (Arctic Front Advance-Short Tip [AFA-ST]) cryoballoon.

Objective: In this multicenter study, we evaluated the safety and efficacy of Cryo-AF using the AFA-ST vs the second-generation (Arctic Front Advance [AFA]) cryoballoon.

Methods: We examined the procedural safety and efficacy and the short- and long-term clinical outcomes associated with a first-time Cryo-AF performed in 355 consecutive patients (254/355 [72%] with paroxysmal AF), using either the AFA-ST (n = 102) or the AFA (n = 253) cryoballoon catheters.

View Article and Find Full Text PDF

Introduction: Anti-arrhythmic medications (AAMs) are known to increase cardiac mortality significantly due to their pro-arrhythmic effects. However, the effect of AAMs on non-cardiac mortality has not been evaluated.

Methods: Trials published in English language journals from 1990 to 2015 were thoroughly retrieved by searching websites such as PubMed, Medline, Cochrane Library, and Google Scholar.

View Article and Find Full Text PDF

Background: There are 2 Food and Drug Administration-approved catheters (ThermoCool RF and Arctic Front Advance cryoballoon) for the treatment of drug refractory and symptomatic paroxysmal atrial fibrillation. Each tool is used to ablate the area surrounding the pulmonary veins (PVs). However, no study has described and quantified the ablated surface area after the application of cryoablation lesions with the second-generation cryoballoon.

View Article and Find Full Text PDF

Introduction: Omega-3 polyunsaturated fatty acids (PUFA) have demonstrated to have antiarrhythmic properties. However, randomized studies have shown inconsistent results.

Objective: We aimed to analyze the effect of omega-3 PUFA on preventing potentially fatal ventricular arrhythmias and sudden cardiac death.

View Article and Find Full Text PDF

Objectives: This study describes the histopathologic and electrophysiological findings in patients with recurrence of atrial fibrillation (AF) after pulmonary vein (PV) isolation who underwent a subsequent surgical maze procedure.

Background: The recovery of PV conduction is commonly responsible for recurrence of AF after catheter-based PV isolation.

Methods: Twelve patients with recurrent AF after acutely successful catheter-based antral PV isolation underwent a surgical maze procedure.

View Article and Find Full Text PDF

Background: Changes in the amplitude of the R wave (RWA) on the electrocardiogram (ECG) have been described during acute myocardial ischemia and infarction. However, this has not been well studied in a controlled setting. We hypothesized that significant increase in RWA occurs during early transmural myocardial ischemia.

View Article and Find Full Text PDF

Introduction: The diameter of implantable cardioverter-defibrillator (ICD) leads has become progressively smaller over time. However, the long-term performance characteristics of these smaller ICD leads are unknown.

Methods: We retrospectively evaluated 357 patients who underwent implantation of a Medtronic Sprint Fidelis defibrillating lead at two separate centers between September 2004 and October 2006.

View Article and Find Full Text PDF

Secure key distribution among two remote parties is impossible when both are classical, unless some unproven computation-complexity assumptions are made, such as the difficulty of factorizing large numbers. On the other hand, a secure key distribution is possible when both parties are quantum. What is possible when only one party (Alice) is quantum, yet the other (Bob) has only classical capabilities? We present a protocol with this constraint and prove its robustness against attacks: we prove that any attempt of an adversary to obtain information necessarily induces some errors that the legitimate users could notice.

View Article and Find Full Text PDF

Background: Antral pulmonary vein (PV) ablation with radiofrequency (RF) energy has become widely used as a curative approach for the treatment of atrial fibrillation. In some patients, despite antral ablation, PV entry and exit conduction block (BDB) cannot be achieved with RF energy. Cryoablation inside the PV may be an effective method to achieve BDB.

View Article and Find Full Text PDF

Objective: To compare natural vs. hormone replacement treatment (HRT) for cryo-thaw embryo transfer cycles in patients with frozen embryos from previous ART.

Design And Settings: Retrospective chart review of 164 patients (242 cycles) who underwent natural or HRT cryo-thaw embryo transfer between January 2002 and April 2005.

View Article and Find Full Text PDF