Prothrombin complex concentrates (PCCs) have been associated with a possible risk of thromboembolic complications, potentially attributable to an increased ratio of the plasma concentration of factor II (FII) to antithrombin (AT). We developed a mathematical model to examine the relationship between amounts of PCC or therapeutic plasma administered, and plasma levels of FII and AT. The model showed that PCC produces substantial increases in plasma levels of FII but only small changes in AT, increasing the FII:AT ratio.
View Article and Find Full Text PDFThrombelastography (TEG)/thromboelastometry (ROTEM) devices measure viscoelastic clot strength as clot amplitude (A). Transformation of clot amplitude into clot elasticity (E with TEG; CE with ROTEM) is sometimes necessary (eg, when calculating platelet component of the clot). With TEG, clot amplitude is commonly transformed into shear modulus (G; expressed in Pa or dyn/cm) as follows: G = (5000 × A)/(100 - A).
View Article and Find Full Text PDF