Removal of triclosan from surface water by ozonation was investigated. The results showed that complete elimination of triclosan from a surface water bearing 1-5 mg/L triclosan via continuous ozonation at 5 mg/L, require an ozonation time of 20-30 min depending on pH. Triclosan oxidation followed pseudo-first order kinetics with an apparent reaction rate constant varying from 0.
View Article and Find Full Text PDFTriclosan (TCS); a widely used antimicrobial biocide, exists in several pharmaceutical and personal care products. Due to its wide usage, TCS is detected in wastewater at varying concentrations. Biological treatability of TCS and its effect on chemical oxygen demand (COD) removal efficiency were investigated running laboratory-scale pulse-fed sequencing batch reactors with acclimated and non-acclimated cultures.