X-ray guided procedures are being performed by an increasing variety of medical specialties. Due to improvements in vascular transcatheter therapies, there is an increasing overlap of imaged anatomy between medical specialties. There is concern that non-radiology fluoroscopic operators may not have sufficient training to be well informed of the potential implications of radiation exposure and mitigation strategies to reduce dose.
View Article and Find Full Text PDFThe number and complexity of transcatheter procedures continue to increase, raising concerns regarding radiation exposure to patients and staff. Procedures such as transaortic valve implantations (TAVI) have led to cardiologists adopting higher dose techniques, such as digital subtraction angiography (DSA). This study compared the estimated patient and occupational eye dose during coronary angiography (CA), percutaneous coronary intervention (PCI), TAVI workups (TWU), TAVI, endovascular aneurysm repairs (EVAR), and other peripheral diagnostic (VD) and interventional (VI) vascular procedures.
View Article and Find Full Text PDFThe aim of this study is to investigate the effectiveness of dose reducing software (ClarityIQ) on patient and staff dose during fluoroscopically guided cardiac procedures. Dose measurements were collected in a room without dose reducing software (n = 157) and compared with similar procedures performed in two rooms with the software (n = 1141). Procedures included diagnostic coronary angiography, percutaneous coronary intervention, deployment of cardiac closure devices (for occlusion of atrial septal defect, patent foramen ovale, and atrial appendage) and insertion of permanent pacemakers.
View Article and Find Full Text PDFBackground: Exposure to radiation during fluoroscopically guided cardiac procedures is a cause for concern for both the patient and staff.
Aims: This study sought to compare the occupational and patient radiation dose during femoral and radially accessed invasive coronary angiography (CA).
Methods And Results: Occupational dose (µSv) was measured at the left temple of the cardiologist (n = 17), scrub (n = 27), and circulator nurse (n = 27) during 761 femoral and 671 radially accessed diagnostic coronary angiograms and percutaneous coronary intervention (PCI) procedures.
There is a paucity of literature comparing patient and staff dose during coronary angiography (CA), implantable cardiac devices, permanent pacemakers (PPM) and electrophysiology (EP) procedures and little noting dose to staff other than cardiologists. This study sought to compare patient and occupational dose during a range of fluoroscopically guided cardiac procedures. Radiation dose levels for the patients (n = 1651), cardiologists (n = 24), scrub (n = 32) and scout nurses (n = 35) were measured in a prospective single-centre study between February 2017 and August 2019.
View Article and Find Full Text PDFThis study aimed to evaluate the effect of nurse and doctor height on occupational dose to the temple during fluoroscopically guided cardiovascular procedures. Additionally, an evaluation of the relationship between doctor height and table height was performed. Staff exposed during fluoroscopic procedures may be at elevated risk of cardiovascular damage or oncogenesis and have demonstrated a higher incidence of subscapular cataracts.
View Article and Find Full Text PDF