Irritation testing is an integral part of the biocompatibility assessment of medical devices and has historically been conducted on animals, either by direct contact or with polar and non-polar solvent extracts. In 2018 an ISO-sponsored interlaboratory validation study demonstrated that two reconstituted human epidermis (RhE) based assays, which were adapted from validated methods used for industrial chemicals, produced results essentially equivalent to those obtained with in vivo tests. This led to the publication of the ISO 10993-23:2021 standard on irritation testing, which states that RhE-based assays are now the preferred method.
View Article and Find Full Text PDFPyrogenicity presents a challenge to clinicians, medical device manufacturers, and regulators. A febrile response may be caused by endotoxin contamination, microbial components other than endotoxin, or chemical agents that generate a material-mediated pyrogenic response. While test methods for the assessment of endotoxin contamination and some microbial components other than endotoxin are well-established, material-mediated pyrogens remain elusively undefined.
View Article and Find Full Text PDFSeveral irritants were used in the in vitro irritation medical device round robin. The objective of this study was to verify their irritation potential using the human patch test (HPT), an in vitro assay, and in vivo data. The irritants were lactic acid (LA), heptanoic acid (HA), sodium dodecyl sulfate (SDS), Genapol® X-80 (GP), and Y-4 polymer.
View Article and Find Full Text PDFAssessment of dermal irritation is an essential component of the safety evaluation of medical devices. Reconstructed human epidermis (RhE) models have replaced rabbit skin irritation testing for neat chemicals and their mixtures (OECD Test Guideline 439). However, this guideline cannot be directly applied to the area of medical devices (MD) since their non-toxicity assessment is largely based on the testing of MD extracts that may have very low irritation potential.
View Article and Find Full Text PDFA round robin study using reconstructed human epidermis (RhE) tissues was conducted to test medical device polymer extracts for skin irritation potential. Test samples were four irritant and three non-irritant medical device polymers. Five of these polymer samples were developed and two were obtained commercially.
View Article and Find Full Text PDFToxicol In Vitro
August 2018
Amid growing efforts to advance the replacement, reduction, and refinement of the use of animals in research, there is a growing recognition that in vitro testing of medical devices can be more effective, both in terms of cost and time, and also more reliable than in vivo testing. Although the technological landscape has evolved rapidly in support of these concepts, regulatory acceptance of alternative testing methods has not kept pace. Despite the acceptance by regulators of some in vitro tests (cytotoxicity, gene toxicity, and some hemocompatibility assays), many toxicity tests still rely on animals (irritation, sensitization, acute toxicity, reproductive/developmental toxicity), even where other industrial sectors have already abandoned them.
View Article and Find Full Text PDF